24
Smarty 3X VE / Smarty 3X VE 3.0
www.salda.lt
Heat recovery takes place when air extracted from indoors is warmer than air extracted from outdoors and there is a demand to supply warm air. Cold
recovery takes place when air extracted from indoors is colder than air extracted from outdoors and there is a demand to supply cold air.
Flex remote control has a so-called fast button whose function can be adjusted, if required. Possible functions: Standby mode and Maximum (“Boost”).
Functions can be selected in the remote control settings. The unit is switched from the active “stand-by” mode to the energy saving mode. I.e. in this
mode energy consumed by the unit does not exceed 1 W.
Operation:
If the “fast” button is configured to activate “stand-by” mode, the message “stand-by mode” will be shown on the remote control upon activating this
mode.
Function adjustment, setting:
“Fast button” configuration (Only by “FLEX” remote control):
Menu>additional>Add.Func>Fast Butt.
• “Fast Butt.” – to choose the purpose of the fast button: “Standby” , or “boost/fireplace”
The unit service time till the filter clogging message is set. After the set time expiry the filter clogging message is shown on the remote control. In the
remote control “FLEX” and “Stouch” you can track the filter timer readings and reset the timer.
After filter replacement it is required to reset the filter timing. Filter clog-
ging service time meter is activated in the service menu
“Menu>additional>sevice>FMisc>Ftimer”.
Function adjustment, setting:
By “FLEX” remote control
Menu >
Extra > filters
• “Set Timer” – service hours until the information message for filter replacement are set (designed time till the filter replacement is 2,160 service
Other information:
hours).
• “ReSet Timer” – resetting the meter
• “Curr.Timer” – current number of service hours
“Menu” > “Additional” > “Service” > Misc”
The unit shut-down conditions depending on the remote control connection
• “RC NC” – {On, Off} (default value “off”)
• On – (Remote Control) No remote control, the unit is shut down
• Off – (Remote Control) No remote control, the unit is on
This setting is not effective, if the unit is controlled through the ModBus interface. Where “RC NC” is “off”, the unit is shut down in 10 s.
• Filter timer activation.
• “F Timer” – {On, Off} (default value “On”)
• On – (Filters timer) filter clogging timer is on. In the main user’s menu the item “Filters” appears
• Off – (Filters timer) filter clogging timer is off
By “Stouch” remote control
In Item P.06 of the Stouch user’s menu you can review how many days passed after the filter replacement. If the element B6 at Item P.06 is held down
for 5 seconds, the timer is reset.
No
Description Possible values
Default
value
P
.
06
Filter timer 0 – 999 days
0
Where STouch remote control is used, all settings made by Flex remote control are no longer used. Filter timer is recorded in the
Stouch remote control.
When the time indicated by “STouch” remote control is over, the accident is shown “A.03”. When accident A.03 is cancelled, the filter timer is also