Salda RIS 2500HW EKO 3.0 Technical Manual Download Page 27

27

RIS 2500HE/HW EKO 3.0

X4

RS485_1

Fjernbetjening FLEX

Пульт управления (FLEX)

Remote controller (FLEX)

Bedienpult (FLEX)

I/O

-

-

X32

1

LOW

Beskyttelse af el-varmeflade ved overophedning

Защита электрического нагревателя от 

перегрева

Electrical heater guard from overheating

Überhitzungsschutz des Elektroheizers

I

-

-

X32

2

MID

Rotor beskyttelse

Защита роторного теплообменника

Rotor guard

Schutz des Rotorwärmetauschers

I

-

-

X32

3

HIGH

BOOST, hæver ventilator hastighed

BOOST,начинается интенсивная вентиляция

BOOST, increase the flow of air.

BOOST, Beginn der Intensivlüftung

I

-

-

X32

4

COM

COM

-

-

-

X33

1

TIMER

Stop

DI

-

-

X33

2

COM

COM

-

M5

Motorventil vand køleflade

Привод клапана водяного охладителя

Water cooler valve actuator

Antrieb des Ventils des Wasserkühlers

X33

3

VAL+

Ventil køling åbner PWM 24V/50Hz

Открытие заслонки охладителя PWM 24v/50hz

Cooling valve opening PWM 24v/50hz

Öffnen der Kühlungsklappe PWM 24v/50hz

AO

-

-

X33

4

VAL-

Ventil køling lukker PWM 24V/50Hz

Закрытие заслонки охладителя PWM 24v/50hz

Cooling valve closing PWM 24v/50hz

Schließen der Kühlungsklappe PWM 24v/50hz

AO

-

-

X33

5

VAL

Ventil køling fælles Puls 24V/50Hz

Открытие заслонки охладителя  Pulse 24v/50hz

Cooling valve common Pulse 24v/50hz

Allgemeiner Impuls der Kühlungsklappe PWM 

24v/50hz

AO

-

-

M1

By-pass spjældmotor

Привод обходной заслонки («By-pass»)

By-pass actuator

Antrieb der Bypass-Klappe

X33

6

DMP+

By-pass spjæld åbner PWM 24V/50Hz

Общий сигнал заслонки охладителя PWM 

24v/50hz

Bypass damper opening PWM 24v/50hz

Öffnen der Umgehungsklappe PWM 24v/50hz

AO

100mA

-

X33

7

DMP-

By-pass lukkespjæld PWM 24v/50hz

Закрытие заслонки By-Pass PWM 24v/50hz

By-Pass damper closing PWM 24v/50hz

Schließen der Bypass-Klappe PWM 24v/50hz

AO

100mA

X33

8

DMP

BY-pass normal spjæld PWM

Общий сигнал заслонки By-Pass PWM 24v/50hz

By-Pass damper common PWM 24v/50hz

Öffnen der Bypass-Klappe PWM 24v/50hz

AO

100mA

DX

DX køler eller vand køleflade, kontrol af ventil

Управление циркуляционного насоса фреонового охладителя 

или водяного обогревателя

DX cooler or water heater circulatory pump control

Kontrollieren des Freonkühlers bzw. der Zirkulationspumpe von 

der Wasser-Erwärmungseinrichtung

X33

9

CHIL

DX køling ON/OFF 24V

DX охлаждение ON/OFF 24V

DX cooling ON/OFF 24V

DX Kühlung EIN/AUS 24V

DO

0.05mA

-

X33

10

COM

COM

-

X33

11

ALARM

Vises når der er fejl ventilator ON/OFF 24V

Индикация поломки вентилятора/-ов ON/OFF 

24V

Indicates when fans fail ON/OFF 24V

Anzeige defekten Lüfters / defekter Lüfter EIN/

AUS 24V

DO

0.05mA

-

X33

12

ANTI.F

Vises når ventilator kører ON/OFF 24V

Индикация работы вентилятора ON/OFF 24V

Indicates when fans running ON/OFF 24V

Anzeige laufender Lüfter EIN/AUS 24V

DO

0.05mA

-

M6

Motorventil vandvarmeflade

Привод клапана обогревателя воды

Water heater valve actuator

Antrieb des Ventils der Wasser-Erwärmungseinrichtung

X33

13

B.0.10

Varmeflade kontrol signal 0-10V

Сигнал управления электрическим/водяным 

нагревателем 0-10V

Electric/Water heater controll signal 0-10V

Steuerungssignal des Elektroheizers/Wasserheiz-

ers 0-10V

AO

5mA

-

X33

14

COM

COM

-

-

-

X33

15

A.0.10

By-pass eller Rotor 0-10V

X33

16

COM

COM

-

-

-

X33

17

+24V

24VDC

O

0.1A

-

X33

18

COM

COM

-

-

-

T1

+

TV

Frosttermostat

Противозамерзающий термостат водяного обогревателя.

Water heater antifreeze thermostat.

Frostbeständiger Thermostat der Wasser-Erwärmungseinrichtung.

+

Returvandsføler 

Противозамерзающий датчик температуры возвратного 

теплоносителя водяного обогревателя.

Water heater antifreeze return heat carrier temperature sensor.

Frostbeständiger Temperatursensor des zurückkehrenden 

Wärmeträgers von der Wasser-Erwärmungseinrichtung.

X33

19

T.WAT

Returvand temperatur sensor

Температурный датчик возвратной воды

Return water temperature sensor

Rückwassertemperatursensor

AI

-

-

X33

20

COM

COM

-

-

-

TL

Udeluft temperatur føler

Датчик свежего (наружного) воздуха.

Fresh (ambient) air temperature sensor.

Temperatursensor der frischen Luft (der Außenluft).

X33

21

T.OUT

Frisk luft sensor

Наружный датчик

Outdoor sensor

Außensensor

AI

-

-

X33

22

COM

COM

-

-

-

X33

23

T.SET

Udsugningskanal, tryktransmitter, CO2 sensor,0-

10V

Вход сигнала вентилятора вытяжного воздуха 

0-10V CO2 из преобразователя/-ей

Extract air fan 0-10V pressure, CO2 transmitters

Druck des Abluft-Lüfters 0-10V, CO2-Sensor

AI

-

-

X33

24

COM

COM

-

-

-

Summary of Contents for RIS 2500HW EKO 3.0

Page 1: ...nd Design sind vorbehalten Subject to technical modification RIS 2500HE HW EKO 3 0_P0018_AQ_0002 RIS 2500HE HW EKO 3 0 AGGREGAT MED VARMEGENVINDING AHU WITH HEAT RECOVERY L FTUNGSGER TE MIT W RMER CKG...

Page 2: ...beskyttelse 16 Ved at bruge enheden i BMS netv rk 17 ModBus adresser 18 Elektrisk tilslutning 19 System retningslinjer for justering 20 Grundl ggende fejl i anl g og probleml sning 22 Kontrol board RG...

Page 3: ...ater 31 Product maintenance table 32 Inhalt Transport und Lagerung 4 Beschreibung 4 Schutzmassnahmen 4 Bestandeile des Ger tes 5 Betriebsbedingungen 5 Bedienung 6 Filter 6 Ventilator 6 W rmetauscher 7...

Page 4: ...entangled in to operating unit Do not place fingers or other foreign objects through inlet or exhaust guards or into con nected duct Should a foreign object enter the unit immediatelly disconnect pow...

Page 5: ...f hrliche Spannung haben 1 Geh use 2 Steuerkasten 3 Abluftklappe 4 Stellantrieb der Abluftklappe 5 Temperaturf hler der Abluft 6 Abluft Filer 7 Elektrischer W rmer nur RIS 2500HE EKO 3 0 8 W rmetausch...

Page 6: ...stehen bleiben Anl gget kobles fra str mforsyningen vent ca 2 minutter til ventilatorerne er stop pet helt f r d kslerne bnes 2 Dirt increases air resistance in the filter there fore less air is suppl...

Page 7: ...can be identified only by a qualified professional If necessary the electrical heater can be re moved Disconnect the electrical connector from the heater and remove the heater Pic a b c Das Elektro H...

Page 8: ...eistungsaufnahme str m power current Nennleistung Nennstrom kW A 5 49 13 69 1 89 8 49 Integreret automatisk kontrol Automatic control integrated Integriertes Steuerungsystem Effektivitet Thermal effic...

Page 9: ...2 mm 90 Indsugning supply Zuluft F7 Bredde Width Breite L mm 790 H jde Height H he H mm 528 Dybde Depth Tiefe L2 mm 90 Filter model Filter model Filter Modell MPL Der tages forbehold for ndringer og r...

Page 10: ...es even though the level of noise caused by the fans is admissible The installation is rec ommended at the distance of 400 mm from the nearest wall If it is not possible the installation of the unit i...

Page 11: ...ater reaches sewerage system 5 In other case premises can be flooded Draining system must be installed in the premis es where the temperature is not lower than 0 C If temperature falls below 0 C the d...

Page 12: ...t automatisk kontrol system DTJ Temperatur og fugtsensor for udsugning M1 Spj ldmotortil by pass M2 indbl snings spj ld M3 Udsugnings spj ld PS1 Filtervagt indbl sning PS2 Filtervagt udsugning IV PV P...

Page 13: ...her Stellantrieb SSP Firkantet lydd mper Rectangular duct silencer Schalld mpfer f r rechteckige Luftf hrungskan le OC Udend rs rist Outlet Cover Branch pipe Outlet Cover Outlet Cover Ausblas Ansaugst...

Page 14: ...nterschreitet wird die Bypass Klappe geschlossen frische Au enluft wird durch den Plattenw rmetauscher eingelassen Wenn in derAnlage ein Rotorw rmetauscher eingerichtet ist wird dann sein Drehen gesto...

Page 15: ...elltaste des FLEX Pultes gesteuert wird wird Boost nach dem ersten Dr cken der Taste f r 5 Minuten aktiviert nach dem zweiten Dr cken der Taste wird Boost sofort deaktiviert Maximale Einstellung 255 M...

Page 16: ...Kapillarthermoschutzes d h dem Handschutz und dem automatischen Schutz gesichert Automatischer Thermoschutz l uft an wenn die Lufttemperatur 50 C ber schreitet Handthermoschutz l uft an wenn die Luftt...

Page 17: ...RTU RS485_2 port is used for connecting the ModBus Fig 3 Settings see section II 6 2 of the FLEX installer description Fig 3 RS485_1 and RS485_2 RS485_1 remote control panel socked RS485_2 Mod Bus po...

Page 18: ...n Exhaust air temperature sensor alarm de Abluft Temperatursensor Alarm 1 active o passive 8 Tlimit 01h_Read_Coils 8 1 dk Indbl snings temperatur sensor alarm ru en Supply air temperature sensor alarm...

Page 19: ...uerpult muss auf dem vorgesehenen Platz montiert werden Anschlusskabel FLEX der ein Teil der Aus r stung ist muss zwischen dem Steuerpult und dem HKLK Aggregat gelegt werden Empfehlenswert wird der Be...

Page 20: ...8 17 16 17 18 X16 4 19 25 24 X16 7 23 28 27 26 29 30 24 23 25 27 26 28 29 21 20 22 20 21 X16 10 14 13 12 11 16 15 11 12 13 14 15 12 11 X16 4 9 10 6 5 4 X16 3 7 8 X16 2 1 2 3 4 5 6 7 8 9 10 10 9 8 7 6...

Page 21: ...ftungsanlage wie fern F hlerkabel l sst bis zur ersten Abzweigung des Lufttransportsystems und Biegung montiert werden Diese Anforderung ist dazu n tig dass das Messergebnis m glichst genau ist Frost...

Page 22: ...nections of the unit St rung in elektrischen Verbindungen Anschl s sen des Aggregats dk Tjek soklen og stik v r sikker p de ikke er beskadige ru en Inspect sockets and plugs of connections Make sure t...

Page 23: ...s not working Ventilator en nicht funktioniert Indbl sning PV eller udsugning IV ventilator fejl PV IV Supply PV or extracted IV air fan fault St rung des Ventilators f r Zuluft PV oder Abluft IV dk T...

Page 24: ...the respective sensor plug from the automation Measure and check the sensor voltage using the bellow dependency Fig 1a If measure ment results do not correspond with the given values replace the retu...

Page 25: ...25 RIS 2500HE HW EKO 3 0...

Page 26: ...e Electric heater Elektroheizer O 16A 100 X29 Elektrisk forvarmer Rotor On off 230V 50Hz Electric preheater rotor ON OFF 230V 50Hz Elektrovorheizer Rotor EIN AUS 230V 50Hz O 16A 100 X12 Sp nding venti...

Page 27: ...DX cooler or water heater circulatory pump control Kontrollieren des Freonk hlers bzw der Zirkulationspumpe von der Wasser Erw rmungseinrichtung X33 9 CHIL DX k ling ON OFF 24V DX ON OFF 24V DX coolin...

Page 28: ...Abzugsluft Temperatursensor AI X38 2 COM X40 1 5V X40 2 Udsugning fugt sensor Extract air humidyti sensor Abluft Feuchtigkeitssensor AI X40 3 COM TJ Indbl sningsf ler Supply air temperature sensor Te...

Page 29: ...inspektion Hvis udstyret er defekt b r k beren informere os inden 8 arbejdsdage og leverer enheden retur til producent eller hvad der nu aftales Leveringsomkostningen d kkes af kunden All equipment m...

Page 30: ...34 7 X34 6 X34 5 X34 4 X34 3 X34 2 X34 1 X33 26 X33 25 X33 17 X33 12 X33 18 X33 14 X33 13 X35 1 X35 2 Y1 Control OPEN AC 24 V Y2 Control CLOSE AC 24 V G System potential AC 24 V 24VDC X16 1 2 1 3 X33...

Page 31: ...1f 230V AC PE L N T1 TV 1 4 10 11 PS3 1 2 RH A4 A4 PUMP AC N V1 COM X37 2 X37 1 COM V2 X37 3 X37 4 X4 X3 ModBus RTU RS485_2 RS485_2 A1 A1 A2 A2 A3 A3 TE TE X52 X33 19 X33 20 COM T WAT TJ X33 22 X33 2...

Page 32: ...filtre Filter replacement Filter Ersatz Kas 3 4 m nesius Hver 3 4 m ned Every 3 4 months Alle 3 4 Monate PASTABA Produkt sigij s asmuo privalo pildyti Gaminio prie i ros lentel Produkt checkiste skal...

Reviews: