8
Typical Installation
Right Pump
Positive Range
The selection of the Right pump positive for a
system will be determined by the resistance
of, quantity of and pressure required by, the
outlets.
To activate a positive head pump :
1 litre per 30 seconds (2 L/min) of water
should be able to flow through each side of the
pump naturally and out of the tap or shower.
This will lift the flow switches and turn the
pump on.
Where this flow cannot be achieved, a negative
head pump is required.
600mm or
less possible
negative head
Usable capacity
minimum 50 gallons
per bathroom
Vent and
other
services
Cold water storage
H
C
Outlet
Inlet
Outlet
Inlet
65
MAX
Min 600mm
Vent and
other services
Inlet
Inlet
Outlet
Outlet
Air vents,
both hot
and cold
Cold water storag e
H
C
Best method is the no
stop Essex Flange with
an anti-gravity loop at
least 400mm in depth
Figure 7: Typical Right Pump Installation -
pump located above the cylinder
Figure 6: Typical Right Pump Installation -
pump located at base of the cylinder
Scan QR to learn more