10
Typical Installations
Right Pump
Universal
Right pump universal to
shower columns or steam
shower cabinets
Figure 9: Right pump universal to a shower
column
Right pump universal to a shower cabinet.
Shower columns and steam shower cabinets in
larger whole house systems or systems with
multiple bathrooms will be best served by two
single-ended Right pump universal.
Single-ended Right pump
universal
The following systems are best accommodated
by using a single-ended Right pump universal
which is complete with a pressure vessel.
Right pump universal to boost tank fed
supplies to instantaneous electric showers and
water heaters.
Figure 10: Instantaneous electric showers and
water heaters
Vent and
other
services
Inlet
Best method is the no
stop Essex Flange with
an anti-gravity loop at
least 400mm in depth
Cold water storag e
H
C
Air vents,
both hot
and cold
MAX
600mm or
less possible
negative head
Outlet
Outlet
Usable capacity
minimum 50 gallons
per bathroo m
600mm or
less possible
negative head
Usable capacity
minimum 50 gallons
per bathroom
C