Salamander Pumps Right Pump Series Installation And Warranty Manual Download Page 25

25

To the installer

Please follow the guidelines for installation 

provided in this brochure and call the 

PumpWise helpline for installation advice. 

Once installation has been completed and the 

system has been tested to your satisfaction, 

please assist the customer in Warranty 

registration online at www.salamanderpumps. 

co.uk or by phone on 0191 516 2002

Terms, conditions and 

warranty

1. The Scope of the Warranty
SALAMANDER PUMPED SHOWER SYSTEMS 

LTD (“the company”) Warrants subject to the 

terms and conditions below for the Warranty 

period(s) specified in paragraph 3 that the 

Company shall:
Repair or replace free of charge the product(s) 

specified on the Online warranty form or 

any component part thereof (together 

referred to as “the equipment”) which shall 

in the opinion of the Company have proved 

defective by reason only of the Company’s 

materials or workmanship providing always 

that the Company shall be under no obligation 

whatsoever under this Warranty to repair or 

replace equipment which have been misused, 

tampered with, modified/altered in any way 

without the consent in writing of the Company 

or if any component or accessory shall have 

been replaced by a type not specified by the 

Company or if the equipment is incorrectly 

installed or operated or used other than as 

described in the instruction manual or if any 

servicing or repair of the equipment shall 

have been carried out otherwise than by an 

authorised Company dealer appointed by the 

Company (“dealer”).
The Company’s liability under this Warranty 

is limited to the said repairs or replacement 

and shall under no circumstances extend 

to any financial loss or damage including 

consequential losses alleged to have been 

suffered by the claimant.

Subject as provided in this warranty and 

except where the equipment is sold to a 

person dealing as a consumer all warranties, 

conditions or other terms implied by law are 

excluded to the fullest extent permitted by 

law.
Nothing in this warranty shall exclude liability 

for death or personal injury caused by the 

Company’s negligence
2. Terms and conditions
This Warranty shall only be enforceable by 

you if the following terms and conditions have 

been complied with:
a. That the pump has been installed in 

accordance with the installation instructions, 

guidance and advice contained within the 

installation and warranty guide and/or 

provided by the Salamander help desk.
 b. You are the original purchaser of the 

equipment from a dealer and not an assignee 

or subsequent purchaser of the equipment.
c. You must evidence the date of purchase by 

retaining the original invoice from the dealer. 

Without such evidence the Company reserves 

the right to reject any such claims under the 

terms of this Warranty.
d. Within 15 days of delivery of the equipment 

to you the Warranty is accurately completed 

online or by phone.
e. Within 30 days of discovery of a defect 

giving rise to liability under paragraph 1 

above you give notice thereof in writing to the 

Company.
f. Provided the pump has not been altered, 

tampered with, modified or transformed in any 

way.
3. The Warranty periods
The Warranty periods referred to in paragraph 

1 above are as follows:
a. Products manufactured by the Company 

3 years from date of purchase provided the 

warranty is completed online or by phone 

within 15 days of purchase.

Summary of Contents for Right Pump Series

Page 1: ...d warranty guide for the Right Pump range ISSUE 21 Oct 2021 This document should be given to the end user and retained for future reference Should you need to contact Salamander Pumps you will need th...

Page 2: ...regarding installation The back cover explains the methods to register your pump for the 3 year warranty Please leave this installation guide with the customer for reference to maintenance safety info...

Page 3: ...surevesselinstallation TypicalInstallations RightPumpUniversal 10 Commissioning 12 HelpfulPumpWiseGuidelines 13 ColdWaterSuppliesandStorage Hot WaterBlendingValve 14 HelpfulPumpWiseGuidelines 15 Water...

Page 4: ...bar pressure only exception are the RP50TU and the RP55SU which is in 5m equivalent to 50kPa 0 5 bar pressure We recommend the pump is activated for at least 5 minutes every 4 weeks to exercise all m...

Page 5: ...tres of 15mm pipe All up and over pipe work must be vented at the highest point on the outlet of the pump and a non return valve NRV may require fitting to the hot outlet only Note this is only for th...

Page 6: ...uplers Hoses The anti vibration AV couplers are designed to limit the transfer of pump vibration to the associated pipe work All Salamander AV couplers are BSP x 22mm push fit with built in isolating...

Page 7: ...aximum static head should be 5m equivalent to 50kPa 0 5bar pressure The plumbing installation must comply with TheWater Supply Water Fittings Regulations 1999 and BS EN 806 4 2010 buildings regulation...

Page 8: ...Where this flow cannot be achieved a negative head pump is required 600mm or less possible negative head Usable capacity minimum 50 gallons per bathroom Vent and other services Cold water storage H C...

Page 9: ...no natural flow exists Negative head is also needed for electric showers dishwashers washing machines or where pumped hot water meets mains cold Non ReturnValves Non return valves MUSTNOTbe fitted in...

Page 10: ...accommodated by using a single ended Right pump universal which is complete with a pressure vessel Right pump universal to boost tank fed supplies to instantaneous electric showers and water heaters F...

Page 11: ...valve or before an open outlet Figure 12 Tank fed hot with mains cold Please note mains fed systems require the use of a break tank however for a more suitable alternative please see the Salamander Ma...

Page 12: ...bers This will not happen if the outlet pipework is connected to the pump The best method is Connect discharge pipework Check that all the pump isolating valves are open Fill system Check for leaks DO...

Page 13: ...and creates a vortex which draws air and possibly debris into the pump Coldstorageusablecapacity The usable capacity of cold storage is easily calculated as the capacity of water in the cold tank abo...

Page 14: ...r is factory set at 55 60 C MAX 65 C HWSTMVblendingvalvecontroller A Salamander approved HWS Blending valve controller will protect booster pumps in systems where the temperature of the stored hot wat...

Page 15: ...er level switch which must be positioned 102mm higher than the highest outlet from the cold water storage tank When the water level drops too far the WSP will switch off the pump until the cold water...

Page 16: ...of an approved top entry flange Figure 21 Horizontal cylinders Approvedflanges cylinders The 22mm No Stop Essex and the other approved top entry flanges with extension pipes into the cylinder represen...

Page 17: ...larly on the hot side as illustrated is likely to Interfere with the initiation and smooth operation of the pump Restrict the supply water to the pump and risk internal mechanical damage Figure 24 Inv...

Page 18: ...gall minute shower will use up 50 galls 227 Litres of the cold water storage capacity approx 60 of which 30 gallons 136 Litres will be hot water from the cylinder Storedhotwater temperature Extract f...

Page 19: ...amander Pumps Right Pump range is fully WRAS approved Mechanicalseals Scale deposits in water supplies can cause the mechanical seal to stick if left for long periods without use We recommend the Righ...

Page 20: ...perature 65 C Connections Pump Connections 3 4 BSP Flexible hoses Connections UK Model Isolating valves on all hoses Female x 15mm Push Fit Female x 22mm Push Fit Motor Type A C Induction Motor Duty R...

Page 21: ...Charge 12 psi 18psi 34 psi 12 psi 18 psi 34 psi Connections Pump Connections BSP Flexible hoses Connections UK Model Isolating valves on all hoses Female x 22mm Push Fit x 280mm long Motor Type A C I...

Page 22: ...alamander instructions Check suitability of pump is installation in negative head Check inlet filters are not blocked Check flow rate min of 2l min required on both hot and cold Float sticking in outl...

Page 23: ...or system Ensure pump is sufficient to run the equipment Hot temp set too high Reduce cylinder stat setting to 65 C max or fit HWS TMV Pump starts with all outlets closed Leak in system Check for leak...

Page 24: ...ate of purchase and is subject to the installation guidelines being followed correctly please refer to our Pre Installation Checklist on page 2 and our Commissioning Checklist on page 11 For a standar...

Page 25: ...replacement and shall under no circumstances extend to any financial loss or damage including consequential losses alleged to have been suffered by the claimant Subject as provided in this warranty a...

Page 26: ...pect of any service engineer s time and replacement of any parts Please speak to ourTechnical Support team for further details and confirmation of costs e ThisWarranty is given in addition to and does...

Page 27: ...27...

Page 28: ...28 Registeryourwarranty Applyonlineat www salamanderpumps co uk Applybyphone 01915162002 Unit2cColimaAvenue EnterpriseParkWest Sunderland SR53XE Getintouch we reheretohelp calluson01915162002...

Reviews: