Step 2: Connecting the pump
Use only Salamander supplied AV couplers to connect the pump.
All associated pipework MUST be thoroughly flushed before making final connections
to the pump. Fill the pump with water before connecting to the discharge pipework.
The in-line strainers must be fitted to the hot and cold inlet supplies to the pump.
A Hose to pipework
The anti-vibration coupler nuts need
only be finger tight plus one quarter turn.
Mechanical tools must not be used to
tighten plastic coupler nuts as this may
cause damage which will invalidate the
warranty.
B Hose to pump
Do not twist or bend anti-vibration hoses
as this will invalidate the warranty.
Ensure that there are suitable means
of isolation for maintenance
Filter washers MUST be fitted to the inlets of the pump to validate your warranty.
Flat washers must be fitted to the outlets. Flat and filter washers are supplied with
the pump.
Isolating valve
shown in ‘On’
position
Isolating valve
shown in ‘Off’
position
Flat washer
Fit to outlet
Filter
washers
Flat
washer
Filter washer
Fit to inlet