9
Commissioning
Before you finish
Fit pump inlet filters and vibration dampening feet.
It is CRITICAL to discharge water through the pump into a container using natural
flow before connecting the pump to outlet pipework in order to ensure the air has
been discharged from inlet pipework and pump chambers. This will not happen if
the outlet pipework is connected to the pump. The best method is:-
•
Connect discharge pipework, not outlet pipes.
•
Check that all the AV coupler isolating valves are open.
•
Fill system. Check for leaks.
•
DO NOT RUN PUMP DRY – to do so will cause irreparable damage to your pump and
will invalidate your warranty.
•
Open shower mixer valve/system outlets to maximum hot and cold to check the natural flow
(unpumped) MUST be at least 1 litre in 30 seconds per side and 2 litres in 30 seconds mixed.
•
Open hot water outlets fully for 5 to 6 seconds and then turn outlets off. Then open cold
water outlets fully for 5 to 6 seconds and turn outlets off. If flow is poor and inconsistent
repeat above steps until flow is steady.
•
Repeat 2-3 times
The hot connection must be via an
approved side or top entry flange
MAX
60°C
Outlet
Outlet
Inlet
Inlet
x140812_SP_p2_rr_x140812_SP_p2_rr 16/10/2014 13:00 Page 9