5
The stored hot water temperature must not
exceed 60ºC.
Ensure that the hot supply to the pump is via
a Salamander approved method. (Figure 3)
Jointing compounds (boss white, hemp and steel
wool) must not be used. Solder fluxes must not
come into contact with the pump.
The anti-vibration hoses must not be twisted
or bent.
Higher rated fuses must not be used.
A Salamander S flange or one
of the 22mm approved top entry
flanges (see page 14)
22mm No Stop Essex flange with
76mm dip pipe and birds beak cut
end to limit air being drawn into
the pump
Indirect coil
Pump inlet
Outlet
OR ALTERNATIVELY
Pump at the base of cylinder
MAX
60°C
Cold water storage
Inlet
Min 600mm
Air vents,
both hot
and cold
Outlet
Vent and
other services
No Stop Essex Flange
MUST
be used with
an anti-gravity loop at
least 200mm in depth
MAX
60°C
MAX
60°C
Inlet
Outlet
Figure 3: Hot water supply method
Figure 4: Anti-gravity loop
x140812_SP_p2_rr_x140812_SP_p2_rr 16/10/2014 13:00 Page 5