Salamander Pumps CT FORCE 15 PT Installation And Warranty Manual Download Page 20

Salamander Pumped Shower Systems Limited

Unit 2c Colima A

venue, Sunderland, SR5 3XE

Tel:

 
0191 516 2002   

 

Fax:
 
0191 548 4445

 

Email:

 [email protected]

6111

W

arranty car

d

Please supply the following information:


User

 name

 

Address

 
Postcode

  

Tel

 No

.


Installer

 name

 
Address

 
Postcode

  

Tel

 No

.


Supplier

 fr

om
 whom

 system

 was
 pur
chased

 

Name

 
Address

 
 
 

Postcode


W

hat
 does

 your
 pump

 boost?

  

Shower

 

M

  

Multiple

 showers

 

M

 

Whole

 house

  

M

  

Other

 (please

 specify)


W

her
e is

 the
 pump

 installed?

  

Loft

 

M

  

Airing

 cupboard

 

M

 

Under

 bath

  

M

  

Other

 (please

 specify)

 

 


 W

hat
 is

 the
 appr

oximate

 distance

 in

 feet
 fr

om
 the
 pump

 to

 the
 cylinder?

 

Horizontal

  

Vertical


W

hat
 is

 the
 appr

oximate

 cold
 water

 stor
age
 capacity

 in

 gallons?

 

25

 

M

 

40

 

M

  

50

 

M

  

70

 

M

  

100

M


How

 is

 the
 hot
 water

 heated?

 

Gas

M

  

Oil

 

M

  

Solid

 fuel
 

M

  

Aga
 

M

  

Electric

 

M


Does

 the
 DHWS

 cylinder

 have

 independent

 contr

ols
 for:

 

Zone

  YES
 

M

  

NO
 

M

  

 

Temper

ature

  

YES
 

M

  

NO
 

M

 

What

 is

 the
 cylinder

-stat
 setting?

10 
W

ho

 chose

 the
 pump?

  

Householder

 

M

  

Plumber

 

M

 

Merchant

 

M

  

S

howroom

 

M

  

Builder

 

M

11 
W

hy

 did
 you
 choose

 a

 Salamander

 pump?

 

Comments

I am
 inter

ested

 in

 an

 extended

 warr

anty
.

  

M

 Please

 tick
 box

Ple

as

e s

en

d d

eta

ils

 o

f t

he

 E

xte

nd

ed

 W

arr

an

ty

 S

ch

em

e

 

an

d a

pp

lic

ati

on

 fo

rm

.

Pump

 

serial

  

number

Model 

 

Date

 of

  

pur
chase

   

_____

 /  _____

 /  _____

Summary of Contents for CT FORCE 15 PT

Page 1: ...2011 Pump installation and warranty guide for the FORCE range of pumps FORCE 15 PT 15 IPT 15 TU 15 ITU FORCE 20 PT 20 IPT 20 TU 20 ITU 20 PS 20 IPS 20 SU 20 ISU FORCE 30 PT 30 IPT 30 TU 30 ITU 30 PS 30 IPS 30 SU 30 ISU ...

Page 2: ...hment 22mm stainless steel braided anti vibration couplers Pump motor Brass nuts Rubber feet Isolation valves Filter washers on the inlets Water inlets Water outlets Pump housing Rubber sealing washers on the outlets ...

Page 3: ...te advice regarding installation Consulting the helpline will entitle your customer to an additional two years warranty FREE UK only all you have to do is to implement our engineer s recommendations for your installation situation and ask your customer to register When the job is finished tear off the final page of this instruction manual and hand it to the householder This page explains the warra...

Page 4: ...in brass ended positive and negative head universal shower pump FORCE 20 PS FORCE 20 IPS 2 0 bar single brass ended positive head shower pump FORCE 20 SU FORCE 20 ISU 2 0 bar single brass ended positive and negative head universal shower pump FORCE 30 A range of brass ended 3 0 bar shower pumps ideal for powerful showering and multi outlet applications FORCE 30 PT FORCE 30 IPT 3 0 bar twin brass e...

Page 5: ...ents FORCE range of pumps 2 Product description 4 Installation instructions 4 Step 1 Pump location 5 Step 2 Connecting the pump 6 Step 3 Electrical installation 9 General specifications 10 Technical specifications 11 Trouble shooting 12 Salamander PumpWise 13 Warranty 14 ...

Page 6: ... IPS FORCE 30 PT 30 IPT 30 PS and 30 IPS are shower specific pumps FORCE 15 TU 15 ITU FORCE 20 TU 20 ITU 20 SU 20 ISU FORCE 30 TU 30 ITU 30 SU and 30 ISU are universal pumps Inlets and outlets are vertical It is essential to ensure that The cold stored water capacity is adequate for the entire household requirements minimum 50 gallons per bathroom 80 gallons for one bathroom plus an en suite showe...

Page 7: ...n a space that is accessible only with the use of a tool 9 An anti gravity loop Figure 4 off a no stop Essex flange must be fitted to all systems where the pump is mounted above the hot outlet from the cylinder In such systems hot water temperature must not exceed 65ºC Salamander S flange fitted to limit air being drawn into pump Indirect coil Pump at the base of the hot water cylinder Pump inlet ...

Page 8: ... a inch no stop Essex flange or a Salamander S flange or other approved top entry flange 14 Never fit to top entry flange if the pump is fitted above the cylinder 15 Check that water storage capacity meets required flow rates particularly at peak demand i e appliances in simultaneous use 16 All up and over pipework must be vented at the highest point on the outlet of the pump 17 Ensure pipe runs m...

Page 9: ... less it is also possible that a negative head pump will be required The negative head range of pumps activate the pump automatically even where no natural flow exists FORCE pumps suitable for negative head operation are the FORCE 15 TU 15 ITU 20 TU 20 ITU 20 SU 20 ISU 30 TU 30 ITU 30 SU and 30 ISU Figure 7 Negative head system 2 litres min natural flow Other supplies Usable capacity Fit an equili...

Page 10: ...sociated pipework MUST be thoroughly flushed before making final connections to the pump Fill the pump with water before connecting to the discharge pipework A Hose to pipework All FORCE pumps are fitted with inch BSP x 22mm push fit connectors with built in isolating valves The anti vibration coupler nuts need only be finger tight plus one quarter turn Mechanical tools must not be used to tighten...

Page 11: ...t in accordance with applicable regulations by a suitably qualified electrician The pump must be connected to the electrical supply using the mains cable with the attached plug This plug must be connected to an accessible socket that has been installed in compliance with BS7671 I E E Wiring Regulations The plug must be accessible at all times ...

Page 12: ...ith BS5000 part 11 Maximum head All Salamander FORCE pumps 15 metres Anti vibration couplers do not bend FORCE are fitted with BSP x 22mm Push Fit with built in isolating valves Mechanical seals Rotary mechanical face seals carbon rotary element with ceramic counter face are used Scale deposits in water supplies can cause the mechanical seal to stick if left for long periods without use Salamander...

Page 13: ...er Pump 4 4 2 2 5 3 0 22mm 4 8 3 255 120 195 9 8 350 210 220 FORCE 20 SP FORCE 20 ISP 2 0 Bar Single End Positive Head Shower Pump 4 4 1 3 1 7 2 0 22mm 4 5 2 200 120 195 6 7 310 210 220 FORCE 30 SP FORCE 30 ISP 3 0 Bar Single End Positive Head Shower Pump 4 4 2 2 5 3 0 22mm 4 5 2 200 120 195 6 7 310 210 220 Positive or Negative Head FORCE 15 TU FORCE 15 ITU 1 5 Bar Twin End Positive and Negative H...

Page 14: ...t bent or distorted Air in system Run system on full hot with pump switched off ie gravity only for several minutes Check cold water storage is correct for installation and pump is fitted to Salamander instructions Ensure cold water refill rate is adequate for installation Check that vents are fitted as described in instructions Wrong size pump for system Ensure pump is sufficient to run the equip...

Page 15: ...iet as possible however no pump is completely silent Correct installation anti vibration couplers straight rubber feet fitted will minimise noise vibration and transmission noise Standards and approvals Splash proof rating IPX2 complies with the requirements of current British and European safety standards for household and similar electrical appliances meets with Compliance with European Communit...

Page 16: ...a maximum of 60ºC if the pump is positioned above the hot outlet from the cylinder contact the PumpWise helpline at any sign of aeration or spluttering of the discharge water from the shower or other outlets Our PumpWise commitment We promise to help you select the right pump and eliminate the risk of incorrect installation We strive to design and manufacture a robust quality product that will del...

Page 17: ...irs or replacement and shall under no circumstances extend to any financial loss or damage including consequential losses alleged to have been suffered by the claimant Subject as provided in this warranty and except were the equipment is sold to a person dealing as a consumer all warranties conditions or other terms implied by law are excluded to the fullest extent permitted by law Nothing in this...

Page 18: ...nt being made under the terms of this Warranty in the circumstances where in the opinion of the Company the defect has not been caused by the Company s materials or workmanship then the Company reserves the right to charge the claimant at its current hourly rates and list prices in respect of any service engineer s time and any replacement of parts e This Warranty is given in addition to and does ...

Page 19: ...Freepost RLXE JHHY HLHJ Salamander Pumps Unit 2c Colima Avenue Sunderland SR5 3XE ...

Page 20: ...r please specify 6 W hat is the approximate distance in feet from the pump to the cylinder Horizontal Vertical 7 What is the approximate cold water storage capacity in gallons 25 M 40 M 50 M 70 M 100 M 8 How is the hot water heated Gas M Oil M Solid fuel M Aga M Electric M 9 Does the DHWS cylinder have independent controls for Zone YES M NO M Temperature YES M NO M What is the cylinder stat settin...

Reviews: