10
Installation
Specifications
Trouble shooting
PumpWise
Warranty
General specifications
Applications
All Salamander pumps are designed to
boost low pressure hot and cold supplies
from tank-fed services. When supplies from
a water heater or a combination boiler
are to be boosted contact the Salamander
PumpWise helpline 0191 516 2002
for guidance.
Voltage
230 volts 50 Hz.
Motor type
Capacitor start and run induction type
motor with stainless steel shaft and in-built
resetting thermal protection (complies with
BS5000 part 11).
Maximum head
All Salamander FORCE pumps – 15 metres.
Anti-vibration couplers
(do not bend)
FORCE are fitted with ¾” BSP x 22mm
Push Fit with built-in isolating valves.
Mechanical seals
Rotary mechanical face seals (carbon rotary
element with ceramic counter face) are
used. Scale deposits in water supplies can
cause the mechanical seal to stick if left
for long periods without use. Salamander
recommends that the pump be run at least
five minutes every four weeks to ‘exercise’
all working parts.
Connections
¾” BSP male.
Initiation
Fully automatic, flow switch operated,
requiring 1ltr in 30 sec per side or 2ltr in
30 sec mixed. Only applies to positive head
pumps.
Temperature
Maximum fluid temperature 65ºC.