Salamander Pumps CT FORCE 15 PT Installation And Warranty Manual Download Page 15

13

Installation

Specifications

Trouble shooting

PumpWise

Warranty

Salamander PumpWise

Salamander PumpWise is your guarantee to:
•  help you select the right pump for the job.
•  avoid installation pitfalls.
•   provide a further TWO YEARS  

WARRANTY FREE (UK only)

All you have to do is to implement the 
technical advice recommendations for any 
specific installation and register the pump 
when installation is complete.

PumpWise helpline 0191 516 2002

PumpWise from Salamander helps customers 
and provides a support service second to 
none. Installers and customers can be sure of 
a speedy response to requests for technical 
help guidance and advice.

Pump noise

Salamander has engineered this product 
range to be as quiet as possible, however no 
pump is completely silent. Correct installation 
(anti-vibration couplers straight, rubber feet 
fitted) will minimise noise, vibration and 
transmission noise.

Standards and approvals

Splash proof rating IPX2; complies with the 
requirements of current British and European 
safety standards for household and similar 
electrical appliances; meets with Compliance 
with European Community Directives (CE). 
Due to continuous improvement and  
updating specifications may be altered 
without prior notice.

Safety in operation

These appliances are not intended for use 
by persons (including children) with reduced 
physical, sensory or mental capabilities, 
or lack of experience and knowledge, 
unless they have been given supervision or 
instruction concerning use of the appliance 
by a person responsible for their safety. 
Children should be supervised to ensure that 
they do not play with the appliance.

Summary of Contents for CT FORCE 15 PT

Page 1: ...2011 Pump installation and warranty guide for the FORCE range of pumps FORCE 15 PT 15 IPT 15 TU 15 ITU FORCE 20 PT 20 IPT 20 TU 20 ITU 20 PS 20 IPS 20 SU 20 ISU FORCE 30 PT 30 IPT 30 TU 30 ITU 30 PS 30 IPS 30 SU 30 ISU ...

Page 2: ...hment 22mm stainless steel braided anti vibration couplers Pump motor Brass nuts Rubber feet Isolation valves Filter washers on the inlets Water inlets Water outlets Pump housing Rubber sealing washers on the outlets ...

Page 3: ...te advice regarding installation Consulting the helpline will entitle your customer to an additional two years warranty FREE UK only all you have to do is to implement our engineer s recommendations for your installation situation and ask your customer to register When the job is finished tear off the final page of this instruction manual and hand it to the householder This page explains the warra...

Page 4: ...in brass ended positive and negative head universal shower pump FORCE 20 PS FORCE 20 IPS 2 0 bar single brass ended positive head shower pump FORCE 20 SU FORCE 20 ISU 2 0 bar single brass ended positive and negative head universal shower pump FORCE 30 A range of brass ended 3 0 bar shower pumps ideal for powerful showering and multi outlet applications FORCE 30 PT FORCE 30 IPT 3 0 bar twin brass e...

Page 5: ...ents FORCE range of pumps 2 Product description 4 Installation instructions 4 Step 1 Pump location 5 Step 2 Connecting the pump 6 Step 3 Electrical installation 9 General specifications 10 Technical specifications 11 Trouble shooting 12 Salamander PumpWise 13 Warranty 14 ...

Page 6: ... IPS FORCE 30 PT 30 IPT 30 PS and 30 IPS are shower specific pumps FORCE 15 TU 15 ITU FORCE 20 TU 20 ITU 20 SU 20 ISU FORCE 30 TU 30 ITU 30 SU and 30 ISU are universal pumps Inlets and outlets are vertical It is essential to ensure that The cold stored water capacity is adequate for the entire household requirements minimum 50 gallons per bathroom 80 gallons for one bathroom plus an en suite showe...

Page 7: ...n a space that is accessible only with the use of a tool 9 An anti gravity loop Figure 4 off a no stop Essex flange must be fitted to all systems where the pump is mounted above the hot outlet from the cylinder In such systems hot water temperature must not exceed 65ºC Salamander S flange fitted to limit air being drawn into pump Indirect coil Pump at the base of the hot water cylinder Pump inlet ...

Page 8: ... a inch no stop Essex flange or a Salamander S flange or other approved top entry flange 14 Never fit to top entry flange if the pump is fitted above the cylinder 15 Check that water storage capacity meets required flow rates particularly at peak demand i e appliances in simultaneous use 16 All up and over pipework must be vented at the highest point on the outlet of the pump 17 Ensure pipe runs m...

Page 9: ... less it is also possible that a negative head pump will be required The negative head range of pumps activate the pump automatically even where no natural flow exists FORCE pumps suitable for negative head operation are the FORCE 15 TU 15 ITU 20 TU 20 ITU 20 SU 20 ISU 30 TU 30 ITU 30 SU and 30 ISU Figure 7 Negative head system 2 litres min natural flow Other supplies Usable capacity Fit an equili...

Page 10: ...sociated pipework MUST be thoroughly flushed before making final connections to the pump Fill the pump with water before connecting to the discharge pipework A Hose to pipework All FORCE pumps are fitted with inch BSP x 22mm push fit connectors with built in isolating valves The anti vibration coupler nuts need only be finger tight plus one quarter turn Mechanical tools must not be used to tighten...

Page 11: ...t in accordance with applicable regulations by a suitably qualified electrician The pump must be connected to the electrical supply using the mains cable with the attached plug This plug must be connected to an accessible socket that has been installed in compliance with BS7671 I E E Wiring Regulations The plug must be accessible at all times ...

Page 12: ...ith BS5000 part 11 Maximum head All Salamander FORCE pumps 15 metres Anti vibration couplers do not bend FORCE are fitted with BSP x 22mm Push Fit with built in isolating valves Mechanical seals Rotary mechanical face seals carbon rotary element with ceramic counter face are used Scale deposits in water supplies can cause the mechanical seal to stick if left for long periods without use Salamander...

Page 13: ...er Pump 4 4 2 2 5 3 0 22mm 4 8 3 255 120 195 9 8 350 210 220 FORCE 20 SP FORCE 20 ISP 2 0 Bar Single End Positive Head Shower Pump 4 4 1 3 1 7 2 0 22mm 4 5 2 200 120 195 6 7 310 210 220 FORCE 30 SP FORCE 30 ISP 3 0 Bar Single End Positive Head Shower Pump 4 4 2 2 5 3 0 22mm 4 5 2 200 120 195 6 7 310 210 220 Positive or Negative Head FORCE 15 TU FORCE 15 ITU 1 5 Bar Twin End Positive and Negative H...

Page 14: ...t bent or distorted Air in system Run system on full hot with pump switched off ie gravity only for several minutes Check cold water storage is correct for installation and pump is fitted to Salamander instructions Ensure cold water refill rate is adequate for installation Check that vents are fitted as described in instructions Wrong size pump for system Ensure pump is sufficient to run the equip...

Page 15: ...iet as possible however no pump is completely silent Correct installation anti vibration couplers straight rubber feet fitted will minimise noise vibration and transmission noise Standards and approvals Splash proof rating IPX2 complies with the requirements of current British and European safety standards for household and similar electrical appliances meets with Compliance with European Communit...

Page 16: ...a maximum of 60ºC if the pump is positioned above the hot outlet from the cylinder contact the PumpWise helpline at any sign of aeration or spluttering of the discharge water from the shower or other outlets Our PumpWise commitment We promise to help you select the right pump and eliminate the risk of incorrect installation We strive to design and manufacture a robust quality product that will del...

Page 17: ...irs or replacement and shall under no circumstances extend to any financial loss or damage including consequential losses alleged to have been suffered by the claimant Subject as provided in this warranty and except were the equipment is sold to a person dealing as a consumer all warranties conditions or other terms implied by law are excluded to the fullest extent permitted by law Nothing in this...

Page 18: ...nt being made under the terms of this Warranty in the circumstances where in the opinion of the Company the defect has not been caused by the Company s materials or workmanship then the Company reserves the right to charge the claimant at its current hourly rates and list prices in respect of any service engineer s time and any replacement of parts e This Warranty is given in addition to and does ...

Page 19: ...Freepost RLXE JHHY HLHJ Salamander Pumps Unit 2c Colima Avenue Sunderland SR5 3XE ...

Page 20: ...r please specify 6 W hat is the approximate distance in feet from the pump to the cylinder Horizontal Vertical 7 What is the approximate cold water storage capacity in gallons 25 M 40 M 50 M 70 M 100 M 8 How is the hot water heated Gas M Oil M Solid fuel M Aga M Electric M 9 Does the DHWS cylinder have independent controls for Zone YES M NO M Temperature YES M NO M What is the cylinder stat settin...