19
If multiple vessels are to be connected to a pumped AccuBoost unit, they should be
connected after the outlet from the pump. It is advised to connect the vessels to the vessel
port on the pump.
To install multiple vessels to a pumped unit:
1. Isolate pump electrically and isolate the mains water supply via the stopcock
2. Release system water pressure by opening an outlet (tap) and allow the vessel to
fully empty
3. Disconnect the vessel hose from the pump vessel port
4. Attach the captive nut of the brass connector from the connector kit to the pump vessel
port, ensuring the supplied washer is used
7. Continue to follow the
Installation instructions
on page 6.
5. Attach the hose from the first vessel to one of the ports on the brass connector
6. Attach the hose from the second vessel to the remaining port on the brass connector
Figure 20
Figure 21
Figure 22