18
If additional water storage capacity is required, multiple vessels can be installed in a system.
NOTE: ONLY ONE PUMP CAN BE FITTED PER INSTALLATION
. Additional vessels should be
connected via a “T” on the vessel port of the pump (for pumped versions). A Salamander
Pumps vessel connector kit (part code TNK-CON-KIT) can be purchased separately to allow
multiple vessels to be connected. The precharge air pressure within all vessels in the system
should be set to the same value.
Please see typical installation examples below: -
11. Multiple Vessels
Figure 18
Figure 19
Note: In all instances, the installation must comply with the latest water, electrical and building regulations
Unpumped
Combi Boiler/
Unvented
Cylinder
Outlets
Maintenance
bypass
(isolating valve
not supplied)
Pumped
Combi Boiler/
Unvented
Cylinder
Outlets
Recommended upstream
plumbing
(not supplied)
Maintenance
bypass
(isolating valves
not supplied)
Double
check
valve
Pressure
reducing
valve
Stop
cock
Recommended upstream
plumbing
(not supplied)
Double
check
valve
Pressure
reducing
valve
Stop
cock
Inline
strainer