PARTS

ID 

QTY  PART NUMBER 

DESCRIPTION

 

(1)  

PHK-740 (bag)

 

Display Mounting Fastener Set - Metric

(4) 

301-695 

M8 x 16mm Pan phillips screw 

(4) 

301-710 

M6 x 20mm Pan phillips screw

(4) 

301-720 

M4 x 20mm Pan phillips screw

(4) 

301-715 

M5 x 20mm Pan phillips screw

(4) 

301-700 

M8 x 30mm Pan phillips screw

(4) 

301-735 

M8 x 40mm Pan phillips screw

(4) 

302-281 

M6 x 14mm Pan phillips screw for Surface Hub 2S

(3) 

300-485 

1/4-20 x 1/2” Button head socket cap screws 

I

 

(2) 

400-120 

Velcro cinch strap with logo

(3)  

400-125 

Black one-wrap strap x 200mm

(6) 

300-468 

1/4 Flat washer 

   

 

(4) 

300-470 

5/16” flat metal washer

(4) 

400-010 

Black 5” cable ties

(1) 

400-060 

3/16” hex key - long arm

(1) 

400-080 

5/32” hex key

(1) 

400-070 

1/8” hex key

(2) 

 

Mounting Rail

(2) 

 

Leveler Foot

 

(1) 

PHK-735 (bag) 

Wall mount screw set 

(4) 

301-730 

Lag screw 5/16” x 2.5

(4) 

301-055 

Plastic wall anchor

(4) 

301-730 

Washer 5/16” flat washer

(2) 

P-305-063 

Display interface bracket

M

P

O

N

J

I

A

B

K

L

S

T

U

R

Q

V

301-720 301-715 301-700

301-735

300-485

302-281

C

D

E

F

G

H

Summary of Contents for FPS2W/EL/MS/GG

Page 1: ...S 4 20 page 1 of 24 ADA COMPLIANT SOLUTIONS fps2W el MS gg Electric Lift Wall Stand user manuAl 2020 Microsoft Microsoft the Microsoft logo Microsoft Surface Surface and the Microsoft Surface logo are...

Page 2: ...1 M6 x 14mm Pan phillips screw for use with Surface Hub 2S H 3 300 485 1 4 20 x 1 2 Button head socket cap screws I 2 400 120 Velcro cinch strap with logo J 3 400 125 Black one wrap strap x 200mm K 6...

Page 3: ...ire electric shock or injury to persons For indoor use in dry locations only For commercial use Disconnect power when installing relocating or before servicing Unplug from outlet before putting on or...

Page 4: ...onnect the device to a properly grounded outlet only Do not defeat the safety purpose of the polarized type plug A polarized plug has two blades with one wider than the other If the provided plug does...

Page 5: ...Surface www salamandercommercial com 501 685 MS 4 20 page 5 of 24 ASSEMBLY Unbox remove panels Lay flat on floor 1 Slide outer panel away from base and then up and off the unit 2 Remove inner panel by...

Page 6: ...ble of supporting the load The product is designed for installation to 2x4 wood stud or masonry not un reinforced metal studs WOOD CONSTRUCTION locate two framing studs minimum of 16 405 mm apart at t...

Page 7: ...e Set stand aside and drill holes for 5 16 lag screws S WOOD CONSTRUCTION Use 3 16 5mm bit and drill holes 2 5 64mm deep MASONRY Use 3 8 10mm bit and drill holes 2 5 64mm deep Reposition stand and sec...

Page 8: ...rom Display to Stand Manage cables carefully Use cable ties to keep wires away from pinch points Route cables between the back of display and the hole on the front of stand Use supplied split loom cab...

Page 9: ...Troubleshooting Double check that power cord is firmly plugged into power supply Hold down the down button continuously for several seconds to reset unit More troubleshooting and repair information fo...

Page 10: ...d by the Display manufacturer item 2 below Install Brackets ears out as shown Next insert the four Shoulder Washers item 3 below through the four aligning Key hole Slots item 4 below in the Display He...

Page 11: ...s screw G 4 302 281 M6 x 14mm Pan phillips screw for Surface Hub 2S H 3 300 485 1 4 20 x 1 2 Button head socket cap screws I 2 400 120 Velcro cinch strap with logo J 3 400 125 Black one wrap strap x 2...

Page 12: ...el ctrico o lesiones a personas nicamente para uso en interiores en lugares secos Para uso comercial Desconecte la corriente al instalar reubicar o antes de realizar reparaciones Desconecte del tomac...

Page 13: ...olarizado o con conexi n a tierra Un enchufe polarizado tiene dos clavijas una m s ancha que la otra Un enchufe con conexi n a tierra tiene dos clavijas y un tercer contacto de conexi n a tierra La cl...

Page 14: ...e Cet appareil est con u pour une utilisation en int rieur uniquement dans des endroits secs Cet appareil est con u pour une utilisation commerciale Coupez l alimentation lors de l installation de tou...

Page 15: ...aris e ou de la prise de terre Une fiche polaris e poss de deux lames dont une plus large que l autre Une prise de terre dispose de deux lames et d une troisi me broche de mise la terre La lame large...

Page 16: ...ich an trockenen Orten bestimmt F r den kommerziellen Gebrauch Trennen Sie die Stromversorgung bei der Installation Transport an einen anderen Standort oder vor der Wartung Ziehen Sie vor dem Befestig...

Page 17: ...f nicht aufgehoben werden Ein polarisierter Stecker hat zwei Stifte wobei einer breiter als der andere ist Wenn der mitgelieferte Stecker nicht in die Steckdose passt wenden Sie sich an einen Elektrik...

Page 18: ...lanca Assemblage D baller Enlever les panneaux talez plat sur le sol 1 Faites glisser le panneau ext rieur en l loignant de la base et puis levez le et retirez le de l appareil 2 tez le panneau intern...

Page 19: ...able de supporter la charge Le produit est con u pour une installation sur un montant en bois de 2x4 ou des montants m talliques renforc s CONSTRUCTION EN BOIS Placez deux l ments d ossatures distants...

Page 20: ...ONSTRUCTION EN BOIS Utilisez une m che de 3 16 5mm et percez des trous de 2 5 64mm de profondeur MA ONNERIE Utilisez une m che de 3 8 10mm et percez des trous de 2 5 64mm de profondeur Repositionnez l...

Page 21: ...Les bandes auto agrippantes I J peuvent tre utilis es sur ces rails Acheminer les C bles du Pr sentoir la Base Manipulez les c bles avec soin Utilisez des attaches de c ble afin d loigner les c bles d...

Page 22: ...nneau interne l aide des 2 vis retir es la premi re tape 2 R installez le panneau en alignant toutes les 4 vis qui d passent du panneau travers les ouvertures en forme de serrure sur la base Remarque...

Page 23: ...erminez l installation en ins rant et en serrant les deux vis de verrouillage l ment H travers l en t te d affichage et dans les supports d affichage Befestigen Sie die Anzeigehalterungen Punkt V an d...

Page 24: ...de commande vers le bas en continu pendant plusieurs secondes pour r initialiser l appareil Vous trouverez plus d informations de d pannage et de r paration la page quatre de ce manuel GARANTIE LIMIT...