SAL Nationwide Pty Ltd 40 Biloela Street Ltd, Villawood NSW 2163 ABN 45 144 501 020
Copyright SAL V4 MAR/2018 |
IMPORTANT:
IN THE INTEREST OF PRODUCT PERFORMANCE AND SAFETY PLEASE READ THESE INSTALLATION AND WARRANTY
INSTRUCTIONS BEFORE INSTALLING THE PRODUCT.
SAL products are designed in accordance with all mandatory International and Australian
Standards, which require installation by a qualified installer and regular cleaning and
maintenance of the equipment. Products are sold in accordance with the following
instructions and SAL standard terms and conditions of sale, available via www.sal.net.au.
PIXIE STC/BT TIMER CONTROL,
product electrical and Installation specification effective 18/10/2018.
The PIXIE timer control is designed to operate with one or a group* of PIXIE devices (smart dimmer, smart switch or LED
strip kit) for durations of 1 minute through to 24 hours. *Group configuration must be done with the PIXIE app.
Model No.
Input (V)
Min / Max loads
Colour
Dimension L x W x H (mm)
STC/BT
240
N/A
WHITE
50 X 22 X 22
Nominal frequency (Hz)
- 50
Dimmable
- no
Operating ambient min/max (°C)- 0 to 40
Storage ambient limit (°C)
- 0 to 60
Operating humidity
- +10% to 85% RH, NC Storage humidity
- +10% to 85% RH
Product application
- Interior residential
Product installation orientation - horizontal wall mount
IP rating #
- 20
Pixie connectivity
- yes
Product application:
- Interior / Comm use
Attachment type
- N/A
#IP rating for interior products: T
he designated IP rating is “from below the ceiling” unless
otherwise specified.
#IP rating ALL products:
Termination of the product must be made in accordance with the IP rating.
General product application requirements: (where applicable)
1.
Recycling
: SAL encourages recycling, please consider the environment when disposing of packaging & components.
2.
Switching or test intervals
–
For optimum product performance, good design practice does not encourage 24/7
operation of lighting products without the provision of a routine switching or regulatory test cycle. As a guide for
continual operation installations, a twelve (12) hour duration for Industrial and Commercial applications and a six (6)
hour duration for Residential applications should be considered.
3.
Product maintenance
–
In line with the relevant design standards and to protect your investment, it is important to
have in place a routine cleaning program that reflects the installation environment and maintains the product in a
clean and functional condition. IMPORTANT - The supply must be isolated before any product maintenance or cleaning
is conducted. In addition, damage to ANY cable or cord supplied with the product must be addressed as follows; For
attachment type X having a specially prepared cable, if the external flexible cable is damaged, it must be replaced by
an equivalent cable exclusively available from the manufacturer or authorised installer. For attachment type Y, if the
external flexible cable is damaged, it must be exclusively replaced by an equivalent cable by the manufacturer or
authorised installer. For attachment type Z, if the external flexible cable is damaged, the cable cannot be replaced and
the luminaire must be destroyed.
4.
Adverse, corrosive and coastal installation environments
–
Unless the product is specifically designated for such
applications in these installation instructions, which is supported by a professional maintenance program; installation of
equipment in such environments is not recommended.
5.
Dimming products
–
Dimming circuits and product compatibility must be validated by the installer before installation;
SAL cannot be responsible for third party changes in dimmer compatibility.
6.
Suspended products
–
For installation safety, any suspended products must NOT be installed in high air movement
spaces or locations subject to impact.
7.
Interior downlights and sensors with remote drivers
- The mounting facilities provided for the transformer/driver (if any),
need only be utilized if in the application of the product is required by AS3000. Drivers are not designed for installation
environments that restrict conventional airflow.