8-019
INSPECTION AND ADJUSTMENT
10-2. Measurement of Vibrator Pump Case Pressure
CAUTION
Take care not to operate the vibratory drum for a
longer period of time than necessary with the machine
stationary. Otherwise, the vibrator bearing could be
seized.
Oil temperature during measurement : 50
± 5
°C (122
± 9
°F)
①
Disconnect hose (1) from vibrator pump. Attach pressure
gauge through adapter
ⓚ
.
Adapter
ⓚ
: 12-4LOHL6G5TF
(Parker part number)
Pressure gauge : 0 to 5 MPa (0 to 725 psi)
②
Apply parking brake by pressing parking brake switch
button.
③
Set vibration mode change switch to “ ”.
④
Start the engine and set throttle switch to “FULL”.
⑤
Press F-R lever vibration switch ON.
⑥
Measure pressure when vibration select switch is in
“
” and “
”, respectively.
⑦
Press F-R lever vibration switch OFF as soon as
measurement is finished.
Allowable pump case pressure
: 0.3 MPa (43.5 psi) or less
•
•
•
★
SV540-08009
1
SV540-08009
1
k
PG002190
k
PG002190
Summary of Contents for SV540 Series
Page 1: ...SV540 SHOP MANUAL 3498 6418A 0 ...
Page 2: ......
Page 4: ......
Page 12: ......
Page 13: ...SAFETY ...
Page 14: ......
Page 22: ......
Page 23: ...SPECIFICATIONS ...
Page 24: ......
Page 25: ......
Page 42: ......
Page 43: ...ENGINE AND CONTROLS ...
Page 44: ......
Page 46: ......
Page 48: ......
Page 53: ...HYDRAULIC SYSTEMS ...
Page 54: ......
Page 55: ......
Page 58: ......
Page 60: ......
Page 62: ......
Page 64: ......
Page 66: ......
Page 67: ......
Page 74: ......
Page 76: ......
Page 78: ......
Page 80: ......
Page 84: ......
Page 85: ...ELECTRICAL SYSTEM ...
Page 86: ......
Page 90: ......
Page 92: ......
Page 94: ......
Page 108: ......
Page 118: ......
Page 119: ...VIBRATORY DRUM REAR AXLE ...
Page 120: ......
Page 128: ......
Page 158: ......
Page 160: ......
Page 162: ......
Page 169: ...BRAKE ...
Page 170: ......
Page 172: ......
Page 174: ......
Page 178: ......
Page 179: ...INSPECTION AND ADJUSTMENT ...
Page 180: ......
Page 206: ......
Page 207: ...TROUBLESHOOTING ...
Page 208: ......