background image

4

D

B 1

2

L

L4

H

H1

D

B

L

L3

L 4

L1

H1

D

Fig.  1

1 - casing;
2 - electric motor;
3 - terminal box;
4 - impeller;

1

3

2

4

6

7

5

VRPK 160 4E

VRPK 160 4D

VRPK 150 4E

VRPK 150 4D

VRPK 200 4E

VRPK 200 4D

VRPK 250 4E

VRPK 250 4D

Capacity, 

3

m / h

Voltage, 

V/Hz

Current, 

Ŕ

Power, 

W

Rotation speed, 

min-1

Maximum 

0

Temperature,  C

Fan Type

700

730

630

670

1600

1650

3400

3500

230/50

380/50

230/50

380/50

230/50

380/50

230/50

380/50

1,7

0,6

1,7

0,6

3,0

2,0

11,0

3,4

180

180

180

180

550

750

1500

1500

1450

1455

1450

1455

1475

1465

1500

1470

100

100

100

100

100

100

100

100

VRPK 160 4E / VRPK 160 4D

VRPK 150 4E / VRPK 150 4D

VRPK 200 4E / VRPK 200 4D

VRPK 250 4E / VRPK 250 4D

160

150

200

250

410

410

330

330

485 365

575 435

540

540

600

665

365

365

425

505

525

525

500

500

625 600

700 675

470

470

475

475

205

205

570 515 235

645 620 285

D

B

B1

H

H1

L

L1

L2

L3

L4

Fan Type

Dimensions, mm

Table 1

5 - spigot;
6 - load bearing frame RN-VRPK;
7 - vibration damper .

Table 2

Fig. 2

Summary of Contents for VRPK Series

Page 1: ...VRPK SERIES USER S MANUAL KITCHEN FAN IN SOUND INSULATED CASING...

Page 2: ...irements 6 Installation and Operation Instructions 7 Fan Structure 8 Fan Installation 9 Connection to power mains 10 Troubleshooting and fault handling 11 Storage Regulations 12 Manufacturer s Warrant...

Page 3: ...s access and water ingress protection standard The motor insulation is F rated The delivery set includes Fan 1 piece User s manual Packing The fan designations their parameters and connecting dimensio...

Page 4: ...50 380 50 230 50 380 50 230 50 380 50 1 7 0 6 1 7 0 6 3 0 2 0 11 0 3 4 180 180 180 180 550 750 1500 1500 1450 1455 1450 1455 1475 1465 1500 1470 100 100 100 100 100 100 100 100 VRPK 160 4E VRPK 160 4D...

Page 5: ...y foreign objects in the fan casing which may damage the impeller blades The fan may only be used as intended No modi cations or alterations are allowed The fan is not intended for operation in areas...

Page 6: ...tenance free The power is adjusted by means of transformer control units The fan is connected to the power mains via the terminal box mounted on the electrical motor Provide an additional electric cab...

Page 7: ...7 1 2 3 4 5 6 Fig 3...

Page 8: ...n The recommended automatic breaker nominal current and conductor sections are given in Table 3 2 The power conductor section is 1 5 mm However the conductor section selection shall account for the ma...

Page 9: ...Recommended cable n x S where n is the number of wires 2 and S is the section in mm Fan Type 2 1 2 1 8 3 15 12 5 4 2 1 5 3 1 5 2 1 5 3 1 5 2 1 5 3 1 5 2 1 5 3 1 5 Connection Diagram for fans VRPK 150...

Page 10: ...Noisy operation Check the power switch Check electrical connections against the wiring diagram Clean the impeller The fan should be stored in the original packing in a ventilated area at temperatures...

Page 11: ...are o ered at Seller The accessories operated together with the unit both included and not included into the delivery list as well as other equipment operating jointly with the unit shall not be cove...

Page 12: ...gnized as serviceable Model VRPK ______________ tick the proper model ACCEPTANCE CERTIFICATE WARRANTY CARD Date of production Stamp of the acceptance inspector Sold by name of the vendor stamp of the...

Reviews: