VM1000B
- 41 -
Function
Code
Parameter Name
Setting Range
Default
Property
Address
(HEX)
voltage at instantaneous
power failure
FA.24
Voltage rally judging
time at instantaneous
power failure
0.00s
~
100.00s
0.50s
○
0A18
FA.25
Action judging voltage at
instantaneous power
failure
60.0%
~
100.0%(standard bus voltage)
80.00%
○
0A19
FA.26
Loss of loads protection
options
0: Disabled
1: Enabled
0
○
0A1A
FA.27
Loss of loads detection
level
0.0
~
100.0
%
10.00%
○
0A1B
FA.28
Loss of loads detection
time
0.0
~
60.0s
1.0s
○
0A1C
FA.29
The decimal point of the
frequency in failure state
1: 1 decimal point
2: 2 decimal point
Single-digit: The third fault frequency decimal
point
Ten’s digit: The second failure frequency of the
decimal point
Hundred’s digit: The first failure frequency of
the decimal point
222
○
0A1D
FB Group: swing frequency, fixed length and count
FB.00
Swing frequency setting
mode
0: Relative to the central frequency
1: Relative to the maximum frequency
0
○
0B00
FB.01
Swing frequency
amplitude
0.0%
~
100.0%
0.00%
○
0B01
FB.02
Jump frequency
amplitude
0.0%
~
50.0%
0.00%
○
0B02
FB.03
Swing frequency cycle
0.1s
~
3000.0s
10.0s
○
0B03
FB.04
Triangular wave rising
time coefficient
0.1%
~
100.0%
50.00%
○
0B04
FB.05
Setting length
0m
~
65535m
1000m
○
0B05
FB.06
Actual length
0m
~
65535m
0m
○
0B06
FB.07
Number of pulses per
meter
0.1
~
6553.5
100
○
0B07
FB.08
Set count value
1
~
65535
1000
○
0B08
FB.09
Designated count value
1
~
65535
1000
○
0B09
FC Group: communication parameters
FC.00
Local address
1
~
247
,
0 is broadcast address
1
○
0C00