VERS. 2022.10.14
CWT 315_MAN_EN
19
5 - STARTING AND STOPPING
5.1
STARTING AND STOPPING THE MACHINE
The switch is placed in a convenient position and accessible from the operator's
workplace. It is of the motor protection type with thermal protection, against current
surges and with release coil in the absence of voltage.
For starting
(only after having carried out all the preliminary
operations), press the green button (1 Fig. 5).
For normal shutdown
press the red button (2 Fig. 5).
For Emergency stop
press the red button (2 Fig. 5).
The stopping time from the blade is less than 10 seconds, therefore Directive
2006/42 / EC does not provide for an additional emergency device as it does not
allow to reduce the risk.