13
Southern Hemispheres
Figure 10
5.2. SouthernHemispheres (SOU).
For Southern Hemisphere installations, ignore these(N, S, E, W) and
face
the solar panel to the North
(and in a sunny position) when it
comes to installing the Integrated outdoor transmitter.
Step 1:
Install the Integrated outdoor transmitter and face the solar
panel North.
Step 2:
Console operation is set to Southern Hemispheres(
SOU
in the
time area) in Location division.
Note:
Wind direction sensor has to be adjusted so that the
directions on the sensor are matching with your real location.
Permanent wind direction error
(
read approximately 180º
)
will be
introduced when the wind direction sensor is not positioned correctly
during installation.
Fasten the integrated transmitter to mounting pole brackets with foot-
mounting, two
¢
3 bolts and M3 nuts , as shown in Figure 11