P roblem
S olution
There are dashes (--
.-) on the display
console.
Make sure the remote sensors are not transmitting
through solid metal (acts as an RF shield), or earth
barrier (down a hill).
Move the display console around electrical noise
generating devices, such as computers, TVs and
other wireless transmitters or receivers.
Move the remote sensor to a higher location. Move
the remote sensor to a closer location
Temperature sensor
reads too high in the
day time.
Make sure the thermo-hygrometer is mounted in
a shaded area on the north facing wall.
Indoor and Outdoor
Temperature do not
agree.
Allow up to one hour for the sensors to stabilize due
to signal filtering. The indoor and outdoor
temperature sensors should agree within 2 °C (the
sensor accuracy is ± 1 °C).
Use the calibration feature to match the indoor and
outdoor temperature to a known source.
Indoor and Outdoor
Humidity do not
agree.
Allow up to one hour for the sensors to stabilize due
to signal filtering. The indoor and outdoor humidity
sensors should agree within 10 % (the sensor
accuracy is ± 5 %).
Use the calibration feature to match the indoor and
outdoor humidity to a known source.
Display console
contrast is weak.
Replace console batteries with a fresh set of
batteries.
-32-