background image

Beginners’ manual Series xx7│Document 26/835; Version E 2│22.04.2005 

Saia-Burgess 

Controls AG

Documentation

Introduction

1-3

1

1.3.2  Overview and structure of the documentation

The summary of Saia

®

 PCD Series xx7 documentation given below should help you 

to fi nd the information you need outside this manual. 

Manual for

xx7 beginners

(26/835)

Manual:

PCD3 Series hardware

(26/789)

Beginners

Manual:  

PCD1/PCD2 Series 

hardware (26/737)

Various other

documents at

www.sbc-support.ch

Manual: xx7-specifi c 

aspects of the PCD3

hardware (26/836)

Manual: 

xx7 communication

facilities (26/798)

Manual: xx7-specifi c

aspects of the PCD1/PCD2 

hardware (26/757)

Manual: 

xx7 system functions

(26/797)

Hardware

Detailed information

Manual:

Ethernet with xx7

(26/791)

Manual:

Serial communication

with xx7 (26/794)

Manual:

xx7 webserver

(26/775)

Manual:

xx7 modem library

(26/793)

Summary of Contents for PCD 7 Series

Page 1: ...Beginners manual Series xx7 Document 26 835 Version E 2 22 04 2005 Beginners manual Hardware con guration Series xx7...

Page 2: ...to STEP 7 2 6 2 4 1 Generating a project in Simatic Manager 2 6 2 4 2 Importing a con guration 2 8 2 5 Summary procedure for con guring a Series xx7 PCD 2 10 3 Con guring the hardware 3 1 Rules for th...

Page 3: ...Published version 26 835 E2 22 04 2005 Adapted the way of writing 0 2 Trademarks Saia Saia PCS and Saia PCD are registered trademarks of Saia Burgess Electro nics AG STEP7 SIMATIC S7 300 S7 400 and Si...

Page 4: ...nted all the CPU operating system functionality as rmware components We do not use any miracle chips We are therefore dependent on nobody but our customers gain the advantage of rapid change enhanceme...

Page 5: ...M157 and PCD2 M177 which themselves achieve roughly the same cycle time as the Siemens CPU 315 The PCD2 M487 attains the operating speed of the Siemens CPU 318 1 2 3 How is the Saia PCD Series xx7 co...

Page 6: ...r xx7 beginners 26 835 Manual PCD3 Series hardware 26 789 Beginners Manual PCD1 PCD2 Series hardware 26 737 Various other documents at www sbc support ch Manual xx7 speci c aspects of the PCD3 hardwar...

Page 7: ...f STEP 7 You can import the con guration into STEP 7 as often as you like modify it if necessary and load it into one or more existing systems At a Stop Run transition in the CPU the loaded con gurati...

Page 8: ...mponents e g PCDs I O modules and interface modules Displaying the hardware catalog If the Hardware Catalog window does not display select Window Hardware Catalog This menu option allows you to displa...

Page 9: ...modules that can be tted is dependent on the CPU used Just as in your real system you use the xx7 I O Builder to place I O modules on the PCD The difference is that the CPU is represented in the xx7 I...

Page 10: ...es parameters or addresses Properties of CPUs The properties of the CPUs have a particular bearing on the behavior of the system In the dialog tabs for a CPU you can set the Saia speci c functions suc...

Page 11: ...ported into STEP 7 for further processing Prerequisite You must have opened an existing project or created a new project in the xx7 I O Builder Before you can generate an AWL source you must save the...

Page 12: ...urce has been successfully generated it is ready to be imported into STEP 7 The AWL source is copied into the same directory the project was saved to It is not allowed to change the numbers of these c...

Page 13: ...ply To function correctly the Simatic Manager needs a rack and a power supply These details are not relevant to the Saia PCD functionality The CPU is for the Saia PCD Series xx7 PCD2 which supports th...

Page 14: ...rks Con guration of networks Pro bus Ethernet etc is also handled by Simatic Manager Further information can be found in manual 26 798 xx7 communication facilities 2 4 2 Importing a con guration Prere...

Page 15: ...ce The new STL source appears in the component container 4 Select the AWL source and translate it with menu option Edit Compile Alternatively you can press Ctrl B 5 If you now switch to the S7 Program...

Page 16: ...nd the Extension Boards Select Insert the I O Modules Set the properties of the I O Modules Set the properties of the CPU PCD Save the Configuration Generate the STL Source Import the STL Source into...

Page 17: ...used Slots 1 64 I O modules intelligent I O modules or not used Slot Expansion devices or not used Depending on the PCD CPU used not all slots will be available and visible For the print option Slots...

Page 18: ...onent into the relevant row in the hardware con guration table The xx7 I O Builder checks whether any slot rules are being violated Symbol for a violation of slot rules 3 Repeat steps 1 and 2 until th...

Page 19: ...et tings are dependent on the type of CPU This manual gives a general overview of the possible settings i A detailed description of the individual functions can be found in manual 26 797 Integrated sy...

Page 20: ...llers is shown in the table below PCD type S7 code memory size PCD1 M137 Default 64 kB Con gurable to 64 kB or 128 kB PCD2 M127 Fixed 132 kB PCD2 Mx57 Default 256 kB Con gurable from 64 kB to 512 kB P...

Page 21: ...be translated in the following sequence FCs in descending order FBs in descending order OBs in descending order SFCs in descending order PCD3 M5x47 OEM only SFBs in descending order PCD3 M5x47 OEM on...

Page 22: ...the PCD2 M487 and the PCD3 M5547 the additional memory requirement for the RAM disk is taken from the system memory Date format By default the webserver displays the date from the STEP 7 DATE_ AND_TIM...

Page 23: ...nctions Series xx7 section 8 5 Web server MPI tab As well as the usual MPI interface the PCD2 Series xx7 controllers can also be programmed via a serial user interface This allows the serial interface...

Page 24: ...st match the setting in the SIMATIC Manager the default setting is 19200 baud Modem type The T813 analog modem or the T850 ISDN modem may be selected Time out for hang up The default setting is for an...

Page 25: ...d in manual 26 797 Integrated system functions Series xx7 section 8 6 Peripheral access in OB100 3 4 Con guring digital input output modules The Properties window for digital input output modules has...

Page 26: ...log input output modules General tab The General tab displays the name the order number and the properties of the selected module No settings can be entered in this tab Addresses tab The Addresses tab...

Page 27: ...dules can be found on the Ludwig company website www ludwig systemelektronik de 3 7 Con guring counter modules The Counter Modules catalog contains the following module types PCD2 3 H100 counter modul...

Page 28: ...ere are any address overlaps the xx7 I O Builder will alert you to this and display the next valid address If the address range is entered into the process map the system does not read write cyclicall...

Page 29: ...be con gured via the Measurement tab Extras tab PCD2 3 H150 only The various SSI parameters for the H150 module can be con gured via the Extras tab i Further information on the PCD2 3 H100 module can...

Page 30: ...tains four tabs General Addresses X Axis and Y Axis General tab The General tab displays the name the order number and the properties of the selected module No settings can be entered in this tab Addr...

Page 31: ...ication modules The Communication Modules catalog contains the interface modules for the serial interface on Slot A No properties can be set for the communication modules They are only used as place h...

Page 32: ...s beside this sign are valid only for the SAIA Burgess PCD Classic serie x x 7 Explanations beside this sign are valid only for the SAIA Burgess PCD xx7 serie 4 2 Product and documentation concept The...

Page 33: ...ch References describe projects that have been successfully realized with Saia PCD s after sales The solutions outlined in them will provide many ideas for the use of Saia PCD s in similar projects p...

Page 34: ...oice of high quality componentry quality control checks at various stages of production in circuit tests run in burn in at 85 C for 48h Despite every care the excellent quality which results from this...

Page 35: ...lues standards and culture of PLC engineering All hardware operating systems software tools CPUs interfaces etc have been developed by SBC itself and are marketed as embedded controls With full techni...

Page 36: ...ieich GmbH Co KG Zweigniederlassung der Saia Burgess Oldenburg GmbH Co KG Otto Hahn Strasse 31 33 D 63303 Dreieich Telefon 06 103 89 06 0 Telefax 06 103 89 06 66 E mail sbc info saia burgess com Homep...

Reviews: