background image

Manual: PCD7.D61xx series│Document 26 / 844│Version E 1│30.04.2006

Saia-Burgess 

 Controls Ltd.

Introduction

1-1

1

Introduction

Please read the manual before you use the controls for the first time, and keep it in a 

safe place for later use.

Target group

This manual is written for users with prior knowledge of PC and automation 

technology.

Conventions used

[KEY]  

 

Keystrokes entered by the user are shown in square brackets,  

 

 

 

e.g. [CTRL] or [DEL]

Courier

 

 

Screen output is shown in Courier font, e.g. 

C:\>

Courier Bold

 

Keyboard input by the user is shown in  

 

 

 

Courier Bold font, e.g. 

C:\>DIR

Italics

  

 

Names of buttons, menus or other screen elements to be    

 

 

 

selected, and product names, are given in 

italics

.

Safety instructions

 

Wherever hazardous faults could occur in the automation system, i.e. a fault could 

cause major damage to materials or people, additional external precautions must be 

taken or devices installed (e.g. independent limit switches, mechanical locks etc.), to 

assure/force a safe operating state in the event of a fault.
The user is responsible for checking suitability for the intended purpose, or for use 

under the specified conditions. Saia-Burgess Controls AG offers no guarantee in this 

area.

Qualified staff

The unit described here may only be set up and operated in conjunction with this 

document. A device may only be commissioned and operated by qualified staff. 

Qualified staff in the meaning of the safety instructions in this documentation are 

people authorised to commission, ground and label devices, systems and electric 

circuits according to the standards of the security policy.

Summary of Contents for PCD7.D6120TV010

Page 1: ...Hardware Manual Document 26 844 Version E1 30 04 2006 The PCD7 D61xx series Controls Division...

Page 2: ...on 3 Commissioning 3 1 Power supply 3 1 3 2 Earthing concept 3 2 3 3 Installation 3 2 3 4 Switch on 3 2 4 Technical data 4 1 Physical dimensions 4 1 4 2 Electrical data 4 5 4 3 Environmental condition...

Page 3: ...nitial version 0 2 Trademarks Saia is a registered trademark of Saia Burgess Electronics AG Microsoft Windows 2000 Windows XP Windows CE and the Windows logo are either registered trademarks or tradem...

Page 4: ...nstructions Wherever hazardous faults could occur in the automation system i e a fault could cause major damage to materials or people additional external precautions must be taken or devices installe...

Page 5: ...product described in this documentation EMC Directive DC power supply Devices with DC power supply meet the requirements of EC Directive 89 336 EEC on electromagnetic compatibility and are suitable fo...

Page 6: ...cription 2 1 2 2 Product description The series comprises the PCD7 D6120TV010 and PCD7 D6150TV010 models User side Colour TFT display with resistive touch PCD7 D6120TV010 and PCD7 D6150TV010 Slot side...

Page 7: ...transformer must comply with EN60742 The supply voltage must be checked against the type plate When wiring the power supply and the connector the details on the type plate must be observed Before comm...

Page 8: ...voided Earth connection to use green yellow cable with min 4 mm cross section 3 3 Installation The device should be installed in an RF shielded housing or a metal switching cabinet Adequate ventilatio...

Page 9: ...Technical data 4 1 4 4 Technical data 4 1 Physical dimensions PCD7 D6120TV010 exterior ush mounting dimensions Front plate Width 364 0 mm Height 296 0 mm Aperture size Width 345 0 mm Height 277 0 mm...

Page 10: ...Burgess Controls Ltd Physical dimensions Technical data 4 2 4 PCD7 D6120TV010 dimensions Blick auf die Ger teoberseite Seitenansicht Blick auf die Ger ter ckseite Seitenansicht Blick auf die Ger teunt...

Page 11: ...ysical dimensions Technical data 4 3 4 PCD7 D6150TV010 exterior ush mounting dimensions Front plate Width 452 0 mm Height 357 0 mm Aperture size Width 429 0 mm Height 334 0 mm Depth 124 5 mm Weight ap...

Page 12: ...ess Controls Ltd Physical dimensions Technical data 4 4 4 PCD7 D6150TV010 dimensions Seitenansicht Blick auf die Ger teoberseite Blick auf die Ger ter ckseite Blick auf die Ger teunterseite Seitenansi...

Page 13: ...range 0 45 C Memory Working memory 256 MByte Processor type 1 GHz VIA C3 Chipset VIA 133T integrated graphics Memory card external 128 256 512 MB 1 GB 2 GB Slots PC 104 Interfaces Serial 2x RS232 for...

Page 14: ...he EPC units are tted with a CFA standard type 1 compact ash slot as standard Position of compact ash slot Ejection lever Only compact ash cards from SANDISK may be used in conjuction with the EPC The...

Page 15: ...net 1 2 RJ45 USB 1 2 PS2 mouse keyboard PS 2 mouse and keyboard may only be plugged or removed with the unit switched off Otherwise these input devices will not be recognised by the operating system A...

Page 16: ...ositive pole of the battery must point upwards be visible When the battery is changed the real time clock data will be lost Do not short circuit the battery contacts Risk of explosion Battery should o...

Page 17: ...f the risk to components from electrostatic discharges caused by touch Recommendation at least touch the Minus of the system cabinet of PGU connector before coming in contact with the electronic parts...

Page 18: ...a Burgess Controls Ltd Address Appendix 6 2 6 Address of Saia Burgess Saia Burgess Controls AG Bahnhofstrasse 18 CH 3280 Murten Switzerland Tel 41 26 672 71 11 Fax 41 26 672 74 99 E mail pcd saia burg...

Reviews: