INSTRUCTION MANUAL
Model HC
Reference 219
Rev 2
Page 29 of 46
06/20/2013
2.1.3.1
Replacement / Disposal of Desiccant (continued)
For first time fill-up
For first time fill-up, remove nuts, bolts, yokes, cover, and
gasket from the manway at the top of the tower (ON
LARGE TOWERS WITH MANWAYS).
Remove plug from desiccant fill (ON SMALL TOWERS
WITH THREADED DESICCANT FILLS).
Pour specified amount of desiccant into the tower. Refer to
the Specifications in Section 5 for required desiccant
quantity.
Do not tamp the desiccant.
Replace the manway cover components, or the pipe plug,
and tighten.
Repeat process for other tower.
Make sure all drain and fill ports are in place and properly
tightened. Soap test for leaks before placing the dryer in
service.
To replace used desiccant
To replace used desiccant, do not attempt any
maintenance while dryer is pressurized.
First, isolate the dryer (IF BYPASS VALVING HAS BEEN
INSTALLED), or shut off compressor, turn off dryer, then
slowly depressurize the dryer.
Drain desiccant from tower by removing the plug at the
bottom of the tower and catch the old desiccant in a
suitable container.
When the tower is completely drained, remove the nuts,
bolts, yokes, cover, and gasket from the manway at the top
of the tower (ON LARGE TOWERS WITH MANWAYS).
Summary of Contents for Sahara-Pak HC-1260
Page 40: ...INSTRUCTION MANUAL Model HC Reference 219 Rev 2 Page 40 of 46 06 20 2013 SECTION 4 WARRANTY...
Page 50: ......
Page 87: ...INSTRUCTION MANUAL Model HC Reference 219 Rev 2 Page 45 of 46 06 20 2013 SECTION 7 CUT SHEETS...
Page 128: ...INSTRUCTION MANUAL Model HC Reference 219 Rev 2 Page 46 of 46 06 20 2013 SECTION 8 DRAWINGS...
Page 129: ......
Page 130: ......
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......