INSTRUCTION MANUAL
Model HC
Reference 219
Rev 2
Page 28 of 46
06/20/2013
2.1.2 Adjustments
The inlet air temperature (as indicated on the Instrument Panel) should
be adjusted to obtain the desired temperature/dew point performance
(refer to Specifications in Section 5). This can be accomplished through
manipulation of the inlet piping insulation and/or the compressor
intercooling.
The temperature of the air leaving the dryer aftercooler should be
maintained at or below 90
F. Adjust the cooling water supply as required.
2.1.3 Desiccant
2.1.3.1
Replacement / Disposal of Desiccant
The dryer is filled from the top and emptied from the bottom.
Refer to the General Assembly drawing in Section 8 for
location of fill and drain ports.
Advice for protection:
If desiccant comes into contact with the eyes, rinse eyes
immediately with large amounts of clear water.
If the desiccant is spilled, clean up with effort to minimize the
formation of dust.
In case of fire, there is no restriction on the use of fire
extinguishing material.
A small dust mask must be worn.