5
LU-( BRIGHTNESS ADJUSTING)
LU-(LED BRIGHTNESS ADJUSTING)
BL
(
LCD BACKLIGHT
)
ON-RA(CHOOSE RANGE OF POWER ON)
PRESS [SET(0~9)]TO CHOOSE
,
PRESS [TARE]TO CONFIRM
3.9.1
RANGE
(
SET UPPER AND LOW LIMIT
)
3.9.1.1
WHEN IT SHOWS RANGE
,
PRESS <TARE> ENTER TO SET LIMIT
,
PRESS
<SET/0~9> TO CHOOSE ON OR OFF, ON IS START LIMIT FUNCTION
,
OFF
IS EXIT LIMIT FUNCTION
,
PRESS <TARE> TO CONFIRM.
3.9.1.2WHEN CHOOSE ON AND PRESS <TARE>
,
NOW ENTER TO SET LIMIT
,
“UNDER” LAMP IS LIGHTING , MAX FIGURE IS BLINKING
,
PRESS<SET/0~9> ONCE TO ADD 1
,
PRESS <TARE> TO CONFIRM
,
WHEN
FINISHING AUTO EXIT
AND SET “OVER”(SAME AS SET UNDER
LIMIT).AFTER FINISH SETTING INTO WEIGHING.
3.9.1.3WHEN LOW LIMIT > HIGH LIMIT, IT DISPLAYS OFF, THEN EXIT.
3.9.1.4ALARMING INDICATE:M IS THE WEIGHT
WHEN M≥HIGH LIMIT, “OVER” LAMP IS LIGHTING AND
FLICKERING.
WHEN LOW LIMIT < M < HIGH LIMIT
,
“ACCEPT” LAMP IS
LIGHTING(NOT FLICKERING).
WHEN M≤LOW LIMIT, “UNDER” LAMP IS LIGHTING.
CAUTION
:
WHEN THE DISPLAY IS NOT STABILIZATION, NO LAMP
LIGHTS.
3.9.2 UNITS
(
CHANGE UNIT
)
3.9.2.1
WHEN IT DISPLAYS
UNITS,
PRESS <TARE> TO ENTER
,
PRESS <SET/0~9> TO CHANGE
,
PRESS <TARE> TO CONFIRM. UNITS
:H9(KG)、9(G)、PCS(COUNTING)、
LB.LB(
DECIMAL POUNDS
)、LB.OZ(BRITISH POUNDS. OUNCES)
3.9.2.2
COUNTING
:
WHEN IT DISPLAYS “PCS”, PRESS<TARE>. NOW “PCS” LAMP LIGHTING.
LONGTIME PRESS<ON/ZERO>
,
IT DISPLAYS COUNT AND RETURN TO 0. THEN PUT
THE SAMPLE (AS
MUCH AS POSSIBLE, BUT DON’T MORE THAN MAX.CAPACITY), AFTER STABLE, PRESS<TARE>
.
PRESS
<SET/0~9>
TO ADD 1 AND PRESS<TARE>TO CHOOSE. AFTER FINISHING IT DISPLAY PCS AND PCS LAMP
LIGHTING.
EXIT COUNTING: CHOOSE A UNIT.
CAUTION: PICK QUANTITIES OF MAX LESS 30000
3.9.3 A-OFF(
CHOOSE AUTO POWER OFF
)
WHEN IT DISPLAYS A-OFF
,
PRESS <TARE> TO ENTER
,
PRESS <SET/0~9> TO CHOOSE N
OR Y, N IS NOT IN AUTO POWER OFF SITUATION
,
Y IS AFTER 10 MINUTES IN ZEROING,
AUTO-OFF.
3.9.4 FILT
(
SET DISPLAY MODE
)
WHEN IT DISPLAYS FILT
,
PRESS <TARE>TO ENTER
,
PRESS <SET/0~9> TO CHOOSE FILT-1
OR FILT-2 OR FILT-3 OR FILT-4
,
PRESS <TARE>TO CONFIRM.
FILT-1
:
SINGLE ANIMAL SCALE FUNCTION
,
AFTER PLACE WEIGHT
,
WEIGHT LOCKED IN SEVERAL SECONDS
,
SUITABLE FOR ONE ANIMAL,
CAN NOT USE FOR TRADE SETTLEMENT
FILT-2
:
MANY ANIMALS SCALE FUNCTION
,
AFTER PLACE WEIGHT
,
IT