4.1 - PRODUCT INSTALLATION 

 
- Do not shake the device. Avoid the use of too much force during installation or unit fixing. 
- The unit can be installed on the floor resting on the rubber feet, on the wall, ceiling or on a 
truss.

 

 
 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

WARNING! IT'S REQUIRED

 

the mounting of the safety rope (PLH200 sold 

separately) in the case where the product is hung on 

a wall, ceiling or on a truss. Except when the device 

is placed in the floor, the safety cable is always 

required.

 

Summary of Contents for SG IPLEDBAR18

Page 1: ...Arch Bar IP 65 RGBW FC SG IPLEDBAR18 SG IPLEDBAR9 MANUALE UTENTE USER MANUAL...

Page 2: ...INSTALLAZIONE ED ACCENSIONE p 7 5 ISTRUZIONI PER L USO p 9 6 MANUTENZIONE p 12 7 SPECIFICHE TECNICHE p 13 INDEX 1 INTRODUCTION p 14 2 SAFETY INSTRUCTIONS p 15 3 OPENING AND CONTROL p 17 4 INSTALLATIO...

Page 3: ...e di riciclarlo in maniera responsabile per favorire il riutilizzo sostenibile delle risorse materiali Gli utenti domestici sono invitati a contattare il rivenditore presso il quale stato acquistato i...

Page 4: ...di ancoraggio sia stabile prima di posizionare il prodotto Il cavo di sicurezza deve essere debitamente agganciato al dispositivo e fissato alla struttura di sostegno in modo che in caso di cedimento...

Page 5: ...di dispositivi da collegare alla linea elettrica al fine di evitare sovraccarichi Se il cavo di alimentazione esterno di questa apparecchiatura da illuminazione danneggiato deve essere sostituito con...

Page 6: ...er la verifica ATTENZIONE Se l apparecchio stato esposto a drastici sbalzi di temperatura lasciare spenta l unit finch non raggiunge la temperatura ambiente in quanto la presenza di condensa potrebbe...

Page 7: ...L unit pu essere installata a pavimento in appoggio sugli appositi piedini in gomma a parete a soffitto o su truss ATTENZIONE E OBBLIGATORIO il montaggio della fune di sicurezza PLH200 venduta separat...

Page 8: ...progettato come indicato nella targhetta dei dati elettrici 4 3 COLLEGAMENTO ALLA CATENA DMX Utilizzare un cavo conforme alle specifiche EIA RS 485 bipolare intrecciato schermato 120Ohm di impedenza c...

Page 9: ...o Blu tipo 1 8 Rosso Blu tipo 2 9 Bianco 10 Rosso Bianco 11 Verde Bianco 12 Blu Bianco 13 Rosso Verde Ambra 15 Bianco freddo 15 Bianco caldo Quando il display mostra Pr 01 premere il pulsante SETUP pe...

Page 10: ...le Valore Funzione 1 000 255 Dimmer rosso 2 000 255 Dimmer verde 3 000 255 Dimmer blu 4 000 255 Dimmer bianco 5 000 255 Master dimmer 6 000 255 Strobo Modalit 8 canali Canale Valore Funzione 1 000 255...

Page 11: ...n il canale 6 tra 001 e 027 017 133 Rosso con il canale 6 tra 001 e 027 034 050 Rosso Verde Giallo con il canale 6 tra 001 e 027 051 067 Rosso Verde Bianco con il canale 6 tra 001 e 027 068 084 Verde...

Page 12: ...alla macchina essa entra in modalit Auto protezione e sul display lampeggia la scritta rt Eliminare la causa della sovratemperatura per ripristinare il corretto funzionamento dell apparecchio E previs...

Page 13: ...DBAR9 Modalit operative Auto Master slave DMX512 Regolazione elettronica della luminosit 0 100 DMX 4 6 8 canali Ingresso e uscita alimentazione per il rilancio Max rilancio 3 pz 110V 6 pz 230V SG IPLE...

Page 14: ...duct from other kinds of wastes and recycle it responsibly to promote the sustainable reuse of material resources Home users are encouraged to contact the retailer where they purchased this product or...

Page 15: ...nt is stable before positioning the product The safety cable must be properly attached to the device and fixed to the supporting structure so that in case of failure of the primary supporting system i...

Page 16: ...ices to be connected to the electricity line in order to avoid power overloading If the external power cord of this light is damaged it must be replaced with a special cord exclusively available from...

Page 17: ...verification WARNING If the product has been exposed to drastic temperature changes let the unit turned off until it reaches room temperature because the presence of condensation can damage the produ...

Page 18: ...it fixing The unit can be installed on the floor resting on the rubber feet on the wall ceiling or on a truss WARNING IT S REQUIRED the mounting of the safety rope PLH200 sold separately in the case w...

Page 19: ...n in the electrical data label 4 3 CONNECTION TO THE DMX CHAIN Use a cable conforming to specifications EIA RS 485 pole twisted shielded 120Ohm characteristic impedance and low capacity PROEL DMXD DMX...

Page 20: ...5 Green Blue 6 Blue 7 Red Blue type 1 8 Red Blue type 2 9 White 10 Red White 11 Green White 12 Blue White 13 Red Green Amber 15 Cold White 15 Warm White When the display shows Pr 01 press SETUP button...

Page 21: ...dimmer 3 000 255 Blue dimmer 4 000 255 White dimmer 6 Channels mode Channel Value Function 1 000 255 Red dimmer 2 000 255 Green dimmer 3 000 255 Blue dimmer 4 000 255 White dimmer 5 000 255 Master dim...

Page 22: ...between 001 and 027 051 067 Red Green White with channel 6 between 001 and 027 068 084 Green with channel 6 between 001 and 027 085 101 Green Blue with channel 6 between 001 and 027 102 118 Blue with...

Page 23: ...cally enter in self protection state and the led display will flash rt characters if the thermal protection breaks down Please fix the thermal protection function There is key lock function in this pr...

Page 24: ...G IPLEDBAR9 Operation Mode Auto Master slave DMX512 Electronic Dimming 0 100 DMX 4 6 8 Channels Power input and power output for link Power linking 3 pcs 110V 6 pcs 230V SG IPLEDBAR18 5 pcs 110V 10 pc...

Page 25: ...25...

Page 26: ...26...

Page 27: ...27...

Page 28: ...Proel S p A Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 Mail info proel com Web www proel com...

Reviews: