background image

 
 
 

 
 

15 

 

2. - SAFETY INSTRUCTIONS

 

 
   

Caution! This product is not suitable for household illumination. 

 
Please read this manual before installing and applying power to the  equipment,  follow the 
safety  precautions  listed  below  and  observe  all  warnings  in  this  manual  and  printed  on. 
Please contact a  PROEL  distributor for assistance with any questions  about  how to activate 
the equipment safely. Contact a qualified technician for any maintenance work not described 
in this manual. 
Do  not  modify  the  fixture  or  install  accessories  and  upgrade  kits  that  are  not  the  Proel 
original ones. 
 
People involved in the installation and maintenance of the device must: 
- Be qualified 
- Follow the instructions of this manual in the theaters, in the halls, in the places where the 
events take place, etc. 
 

CHECKS BEFORE INSTALLATION

 

Make sure all the parts for fixing the product are in good condition. 
Make sure that the anchor point is stable before positioning the product. 
The  safety  cable  must  be  properly  attached  to  the  device  and  fixed  to  the  supporting 
structure  so  that,  in  case  of  failure  of  the  primary  supporting  system,  it  has  the  lowest 
possible fall of the device. 
If the safety cable wear, must be replaced with an original spare. 
 

MINIMUM DISTANCE OF ILLUMINATED OBJECTS

 

The projector must be positioned so that the objects hit by the beam of light are at least 1 
meter from the lens of the projector. 
 

MINIMUM DISTANCE FROM FLAMMABLE MATERIALS

 

The product must be positioned so that any flammable material is at least 0.50 meters from 
any point of the surface of the device. Never place filters or other materials over the lens or 
on the optical axis. 
 

MOUNTING SURFACES

 

The device is suitable for mounting on normally flammable surfaces. 
 

REFERENCE TEMPERATURE

 

The ambient temperature range of use of the device varies b 5 ° C (min) and + 40 ° C 
(max), outside of that range the device should not be used. 
The  maximum  temperature  of  the  housing  Tb  =  80  °  C  must  never  be  exceeded.  Ensure  a 
correct ventilation to the product.  
 

 
 

Summary of Contents for SG IPLEDBAR18

Page 1: ...Arch Bar IP 65 RGBW FC SG IPLEDBAR18 SG IPLEDBAR9 MANUALE UTENTE USER MANUAL...

Page 2: ...INSTALLAZIONE ED ACCENSIONE p 7 5 ISTRUZIONI PER L USO p 9 6 MANUTENZIONE p 12 7 SPECIFICHE TECNICHE p 13 INDEX 1 INTRODUCTION p 14 2 SAFETY INSTRUCTIONS p 15 3 OPENING AND CONTROL p 17 4 INSTALLATIO...

Page 3: ...e di riciclarlo in maniera responsabile per favorire il riutilizzo sostenibile delle risorse materiali Gli utenti domestici sono invitati a contattare il rivenditore presso il quale stato acquistato i...

Page 4: ...di ancoraggio sia stabile prima di posizionare il prodotto Il cavo di sicurezza deve essere debitamente agganciato al dispositivo e fissato alla struttura di sostegno in modo che in caso di cedimento...

Page 5: ...di dispositivi da collegare alla linea elettrica al fine di evitare sovraccarichi Se il cavo di alimentazione esterno di questa apparecchiatura da illuminazione danneggiato deve essere sostituito con...

Page 6: ...er la verifica ATTENZIONE Se l apparecchio stato esposto a drastici sbalzi di temperatura lasciare spenta l unit finch non raggiunge la temperatura ambiente in quanto la presenza di condensa potrebbe...

Page 7: ...L unit pu essere installata a pavimento in appoggio sugli appositi piedini in gomma a parete a soffitto o su truss ATTENZIONE E OBBLIGATORIO il montaggio della fune di sicurezza PLH200 venduta separat...

Page 8: ...progettato come indicato nella targhetta dei dati elettrici 4 3 COLLEGAMENTO ALLA CATENA DMX Utilizzare un cavo conforme alle specifiche EIA RS 485 bipolare intrecciato schermato 120Ohm di impedenza c...

Page 9: ...o Blu tipo 1 8 Rosso Blu tipo 2 9 Bianco 10 Rosso Bianco 11 Verde Bianco 12 Blu Bianco 13 Rosso Verde Ambra 15 Bianco freddo 15 Bianco caldo Quando il display mostra Pr 01 premere il pulsante SETUP pe...

Page 10: ...le Valore Funzione 1 000 255 Dimmer rosso 2 000 255 Dimmer verde 3 000 255 Dimmer blu 4 000 255 Dimmer bianco 5 000 255 Master dimmer 6 000 255 Strobo Modalit 8 canali Canale Valore Funzione 1 000 255...

Page 11: ...n il canale 6 tra 001 e 027 017 133 Rosso con il canale 6 tra 001 e 027 034 050 Rosso Verde Giallo con il canale 6 tra 001 e 027 051 067 Rosso Verde Bianco con il canale 6 tra 001 e 027 068 084 Verde...

Page 12: ...alla macchina essa entra in modalit Auto protezione e sul display lampeggia la scritta rt Eliminare la causa della sovratemperatura per ripristinare il corretto funzionamento dell apparecchio E previs...

Page 13: ...DBAR9 Modalit operative Auto Master slave DMX512 Regolazione elettronica della luminosit 0 100 DMX 4 6 8 canali Ingresso e uscita alimentazione per il rilancio Max rilancio 3 pz 110V 6 pz 230V SG IPLE...

Page 14: ...duct from other kinds of wastes and recycle it responsibly to promote the sustainable reuse of material resources Home users are encouraged to contact the retailer where they purchased this product or...

Page 15: ...nt is stable before positioning the product The safety cable must be properly attached to the device and fixed to the supporting structure so that in case of failure of the primary supporting system i...

Page 16: ...ices to be connected to the electricity line in order to avoid power overloading If the external power cord of this light is damaged it must be replaced with a special cord exclusively available from...

Page 17: ...verification WARNING If the product has been exposed to drastic temperature changes let the unit turned off until it reaches room temperature because the presence of condensation can damage the produ...

Page 18: ...it fixing The unit can be installed on the floor resting on the rubber feet on the wall ceiling or on a truss WARNING IT S REQUIRED the mounting of the safety rope PLH200 sold separately in the case w...

Page 19: ...n in the electrical data label 4 3 CONNECTION TO THE DMX CHAIN Use a cable conforming to specifications EIA RS 485 pole twisted shielded 120Ohm characteristic impedance and low capacity PROEL DMXD DMX...

Page 20: ...5 Green Blue 6 Blue 7 Red Blue type 1 8 Red Blue type 2 9 White 10 Red White 11 Green White 12 Blue White 13 Red Green Amber 15 Cold White 15 Warm White When the display shows Pr 01 press SETUP button...

Page 21: ...dimmer 3 000 255 Blue dimmer 4 000 255 White dimmer 6 Channels mode Channel Value Function 1 000 255 Red dimmer 2 000 255 Green dimmer 3 000 255 Blue dimmer 4 000 255 White dimmer 5 000 255 Master dim...

Page 22: ...between 001 and 027 051 067 Red Green White with channel 6 between 001 and 027 068 084 Green with channel 6 between 001 and 027 085 101 Green Blue with channel 6 between 001 and 027 102 118 Blue with...

Page 23: ...cally enter in self protection state and the led display will flash rt characters if the thermal protection breaks down Please fix the thermal protection function There is key lock function in this pr...

Page 24: ...G IPLEDBAR9 Operation Mode Auto Master slave DMX512 Electronic Dimming 0 100 DMX 4 6 8 Channels Power input and power output for link Power linking 3 pcs 110V 6 pcs 230V SG IPLEDBAR18 5 pcs 110V 10 pc...

Page 25: ...25...

Page 26: ...26...

Page 27: ...27...

Page 28: ...Proel S p A Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 Mail info proel com Web www proel com...

Reviews: