3. Cl e an in g 

Clean the 

MorphoRapID™

 body, screen and biometric sensor with a dry, non-abrasive, lint-free cloth and 

only with a cleaning product recommended by Sagem Sécurité. 

During periods of intense activity, the sensor should be cleaned as soon as smears are visible on-screen. 

WARNING 

Avoid  using  any  alcohol  or  by-products  that  could  damage  the 

MorphoRapID™

  body  or  sensor  part  (cracks  may  appear  on  body  or 

prism). 

Examples of corrosive chemicals to be avoided: 

 

acetone, 

 

ammoniac, 

 

benzene, 

 

ethanol, 

 

methanol, 

 

methylated spirit, 

 

petrol, 

 

thichlorethylene. 

 

Summary of Contents for Morpho RapID 1 G Series

Page 1: ...axis 8 bit gray scale Acquisition area 21 x 21 mm 0 8 x 0 8 Wireless modem HSDPA EDGE GPRS 850 900 1800 1900 2100 MHz frequencies WiFi interface 802 11b g radio module Bluetooth interface Bluetooth v...

Page 2: ...DOCUMENT REPRODUCTION AND DISCLOSURE PROHIBITED Humidity Operating 15 RH 95 non condensing Storage 95 Weight 800 g Dimensions 89 x 126 x 185 mm NOTE A removable power cord connects the MorphoRapID to...

Page 3: ...nt does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the...

Page 4: ...areil num rique de la classe B respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada En cas d utilisation du module radio 802 11 afin d viter toute interf rence radio avec le...

Page 5: ...th and only with a cleaning product recommended by Sagem S curit During periods of intense activity the sensor should be cleaned as soon as smears are visible on screen WARNING Avoid using any alcohol...

Page 6: ...se and reasonably foreseeable misuse shall not occur Even so if electrolyte leaks out of the pack and comes into contact with the skin eyes or others parts of body the electrolyte should be flushed im...

Page 7: ...not used for a long time In order to prevent overdischarging the pack should be charged periodically Overdischarging may cause loss of pack performance or damage battery functions So as to keep a cor...

Page 8: ...RODUCTION AND DISCLOSURE PROHIBITED Battery Replacement Here are the instructions to replace the battery Screen Action 1 At the back of the device unlatch the battery cover latches 2 Open the battery...

Page 9: ...000025754 07 AUGUST 2009 9 SAGEM S CURIT DOCUMENT REPRODUCTION AND DISCLOSURE PROHIBITED Screen Action 4 Replace the discharged battery by the charged one insert the new battery 5 Close the battery co...

Page 10: ...shown as a battery icon at the bottom of MAIN MENU The battery levels are detailed in the following table Icon Battery MorphoRapID Use Full optimal Good optimal Medium optimal Low works properly but...

Page 11: ...TION AND DISCLOSURE PROHIBITED Battery Level Battery Level Percentage Check To check the battery level proceed as follows Screen Action 1 Start the MorphoRapID terminal 2 Press SETTINGS then POWER 3 C...

Page 12: ...ss the key as many times as needed to adjust backlight 5 Recommendations General Precautions WARNING The manufacturer cannot be held responsible if the above recommendations are not followed or if the...

Page 13: ...CUMENT REPRODUCTION AND DISCLOSURE PROHIBITED Areas Containing Combustibles It is strongly recommended not to install the Sagem S curit MorphoRapID in the vicinity of gas stations petroleum processing...

Reviews: