Installation Manual

Installation Manual

Installation Manual

Installation Manual

Summary of Contents for TemaKey TK C03

Page 1: ...TK C03 TK C03 TK C03 TK C03 Compact Terminal Compact Terminal Compact Terminal Compact Terminal Installation Manual Installation Manual Installation Manual Installation Manual ...

Page 2: ......

Page 3: ...from the Bottom of the Box 9 INSTALLATION INSTALLATION INSTALLATION INSTALLATION 10 10 10 10 Connecting the Cables 10 Assembling the Terminal Closure Guide 13 Closing the Terminal wall mounted assembly 14 Closing the Terminal Turnstile mounted assembly 16 ACTIVATION ACTIVATION ACTIVATION ACTIVATION 17 17 17 17 Identification via the Service Pin 17 Identification via Bar Code 18 TECHNICAL SPECIFICA...

Page 4: ...armful interference to radio or television reception which can be determined by tuning the equipment off and on the user is encouraged to try to correct the interference by one or more the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receive...

Page 5: ...tructions Mounting Instructions Mounting Instructions Mounting Instructions The cables are attached to an encased box Make sure that you place the box at a height of 120cm from the floor see Figure 1 tube cables 120 cm floor Figure 1 Space requirements for mounting ...

Page 6: ... module RTU Qxx When determining the correct size for power cables refer to the table below Type of cable Length m in relation to effective load AWG mm2 ohm Km 100 mA 200 mA 500 mA 1 A 2 A 5 A 12 3 3 5 7 1754 877 351 175 88 35 14 2 8 8 1136 568 227 114 57 23 16 1 3 14 714 357 143 71 36 14 18 0 9 21 476 238 95 48 24 10 20 0 6 34 294 147 59 29 15 6 22 0 35 52 192 96 38 19 10 4 24 0 2 85 118 59 24 12...

Page 7: ...orms indicated in Table 1 Type of cable Length m in relation to cable capacity AWG mm2 Ohm Km 50nF Km 100nF Km 200nF Km 500nF Km 1uF Km 12 3 3 5 7 2676 1892 1338 846 598 14 2 8 8 2153 1523 1077 681 482 16 1 3 14 1707 1207 854 540 382 18 0 9 21 1394 986 697 441 312 20 0 6 34 1096 775 548 346 245 22 0 35 52 886 626 443 280 198 24 0 2 85 693 490 346 219 155 Table 1 Length capacity of LONWORKS data ca...

Page 8: ...late To attach the terminal support plate follow these steps 1 Drill two holes in the wall to accommodate the plastic anchors that hold up the support plate you must use M4 screws 2 Make sure that the box attached to the wall is aligned with the niche on the lower part of the support plate 3 Use a 4mm slotted screwdriver Anchor Anchor Cables entrance Figure 2 Attaching the support plate ...

Page 9: ... Box As an alternative you can channel the cables so that they exit from the bottom of the box see Figure 3 This alternative procedure consists of the following steps 1 Drill a hole in the breakaway tab and apply a cable clamp with a clutch for the cable tube 2 Remove the cable clamps from the rear side and apply the stopper Anchor Anchor PG9 cable clamp Multi pole cable 15 poles Figure 3 Channell...

Page 10: ...les Insert and fasten the power data and I O cables in the connector see Figure 4 and Figure 5 If there is also a small grounding cable use a cable clamp to connect it to the screw supporting the card Anchor Anchor Breakaway tab for cables exit from bottom Breakaway tab for cables exit from back Figure 4 Connecting the cables 1 ...

Page 11: ...ut 2 input 2 12V grou nd NET A NET B LED on fuse jumper relay 1 jumper relay 2 Figure 5 Connecting the cables 2 You can define each relay as Normally Open NO or Normally Closed NC by setting the jumpers as illustrated in Figure 6 NO NC NO NC normally closed NC normally open NO Figure 6 Auxiliary connections ...

Page 12: ...er supply for lock 12V Ground Dry contact Normally open Exit Lamp Gate busy N O position Figure 7 Clean contacts connection example When the output loads exceed the maximum ratings for the internal relays external relays must be used as shown in Figure 8 N O position Power supply for lamp Power supply for lock Lamp Gate busy Electrolock Power supply for relays Figure 8 External relays example ...

Page 13: ...the terminal closure guide follow these steps 1 Use the 4 special screws to assemble and fasten the terminal closure guide 2 Insert the nut and the special screw in the corresponding niche on the guide see Figure 9 nut screw head Figure 9 Mounting the terminal closure guide 1 Make sure that the fitting is correctly positioned and then insert the flat cable from the front casing in the connector se...

Page 14: ...ounted assembly Closing the Terminal wall mounted assembly To close a wall mounted terminal follow these steps 1 Unscrew the special closure screw by turning it in an anti clockwise direction so that the terminal closure remains fully open in the direction of the wedge 2 Insert the upper shell as indicated in Figure 11 3 Fasten the special closure screw by turning it in a clockwise direction and p...

Page 15: ...Assembling the Terminal Closure Guide Page 15 Figure 11 Closing the terminal wall mounted assembly ...

Page 16: ...ted terminal follow these steps 1 Unscrew the special closure screw by turning it in an anti clockwise direction so that the terminal closure remains fully open in the direction of the wedge 2 Insert the upper shell as indicated in Figure 12 3 Fasten the special closure screw by turning it in a clockwise direction and pushing down on the shell so that the fitting is completely secure 4 Tighten the...

Page 17: ...l magnet as illustrated in Figure 13 to call the service pin This signal is linked to the yellow central service LED which flashes throughout the node configuration procedure 2 The TemaServer in response to the service pin sends a wink command that makes yellow LED flash three times This allows you to verify that the communication to and from the TemaServer is working 3 Check that the service LED ...

Page 18: ...abel The person responsible for installing the terminal must apply this label to the corresponding identification form and indicate the location of the terminal in the appropriate box see example in Table 3 Description of location Office entrance area first floor staircase E Description of TemaServer Panel 2 entrance area first floor staircase E TKC02 RTU K02 Table 3 Example of completed identific...

Page 19: ... for correct operation 0 50 C Inputs Number of inputs 2 Resistance 2 2 Kohm Logic level high 4 0 VDC max positive 18 VDC Logic level low 0 7 VDC min negative 0 5 VDC Relay outputs Number of outputs 2 30VDC 1A 125VAC 200 mA Proxy antenna 125KHz for HID cards Read distance 0 50mm LONWORKS 2 connection Unshielded twisted pair cable in free topology transceiver FTT10A 78Kbps Regulations compliance Dir...

Page 20: ... TemaKey TK C03 RTU K03 code 1500063BA Spare Parts Spare Parts Spare Parts Spare Parts Fuses F1 1A 250V delayed Optional Parts Optional Parts Optional Parts Optional Parts TORX screwdriver TX10 code 1500108AA ...