background image

Hose & Regulator  Assembly  And  Replacement

 

 

 
 

1.

 

a. 

If  the  burner  valve  is open  prior  to  the  LP gas  cylinder service  valve  being  opened, the

 

connection  will interpret this free 

flow of gas to be a leak.

 

b. 

The connection  safety feature will reduce gas 

flow from the regulator to the appliance  to a 

minimal   level.

 

c. 

Be  sure  that  the  burner control  valve  is closed  prior  to  opening the  LP gas  cylinder  service

 

valve to ensure that the connection 

flow limiting device  is not triggered  mistakenly.

 

d. 

If the connection 

flow limiting device  is triggered  mistakenly, close the LP gas cylinder

 

service  valve  and  the  burner  valve,  wait  10 seconds  to  allow  the  device  to  reset,  open  the 
cylinder service  valve,  then  open  the  burner  valve  and  light  the  fireplace as per 

lighting 

instructions.

 

 

2. 

Be  sure  to  protect the  hose  from  any  hot  surfaces.  Serious  danger may  result  if  the  hose 
contacts any  hot  surface.

 

 

3. 

Regular  maintenance of  the  hose  and  regulator:

 

a. 

Inspect the  hose  before each  use  of  the  fire  table.  If  the  hose  shows  signs  of  cracks, 

abrasions,  cuts  or  damage  of  any  kind,  do  not  operate the  appliance. Fix  or  replace  the  hose 
as required before using  the  appliance. Use only  replacement parts  from  the  manufacturer.

 

 

 

b. 

Inspect the  seal  inside  the  v a l v e   on  the  LP gas  cylinder when  replacing the  cylinder or  at 

least  once  per  year.  If  there  is any  indication of  damage,  have  the  seal replaced by  a 

certified 

gas  dealer  before operating the  appliance.

 

 

4. 

Do  not  use  tools  to  tighten the  connection nut  onto  the  LP gas  cylinder  service valve.  Hand 

tighten  only.

 

 

5. 

Be careful to not  cross the threads on the connection when  tightening the connection on to the 
LP gas cylinder service  valve. 

 

 

6. 

“Leak Test” should always be performed after attaching the connection  to the LP gas cylinder service 

valve. (See 

“Checking  for Leaks” section of this manual on page 

12) 

 

7. 

For the connection of the hose and regulator to the LP tank, refer to the 

“Connection” section 

 

of the LP gas cylinder section above. 

 
 
 
 
 
 
 
 
 
 
 
 

7

 

Summary of Contents for GF-1070RDR

Page 1: ...nit for someone else give this manual to him or her to read Improper installation adjustment and save for future reference alteration service or maintenance can cause injury or property damage leave cylinder outdoors DANGER If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 If odor continues keep away from the appliance and immediately call your gas supplier or fire depart...

Page 2: ... 15 Helpful Tips 16 Troubleshooting 17 DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enclosed space such as a camper tent car or home SPECIFICATIONS Product Name Gas Type Gas Fire Pit LPG or Natural Gas Model No GF 1070RDR 1070SQR 910CDR etc Heat input 10 inch burner 12kW 13inch b...

Page 3: ...be closely supervised when in the vicinity of this outdoor fire table Do not hang or place clothing or other flammable materials on or near the gas fire table Any guard or protective device removed for servicing the appliance shall be replaced prior to operating the appliance Installation and repair should be done by a qualified service person The appliance should be inspected before use and at lea...

Page 4: ... of this outdoor fire table while it is in operation DO NOT use this outdoor fire table near automobiles trucks vans or recreational vehicles DO NOT use this outdoor fire table under any overhead structure or near any unprotected combustible constructions Avoid using near or under overhanging trees and shrubs Always use this outdoor fire table on a hard level non combustible surface such a concrete ro...

Page 5: ...NGER This outdoor fire table is for use with LP G an d n a tural gas only The conversion to or attempted use of natural gas in this outdoor fire table is dangerous and could result in serious personal injury or property damage ATTENTION Any alteration of the outdoor fire table that is not specifically directed in the operations manual will void manufacturer warranty LP GAS Dangers And Warnings LP ...

Page 6: ...d LP gas dealer Use the regulator that it shall comply with the EN 16129 pressure Never attempt to attach this appliance to the self contained LP gas system of a camper trailer motor home or house Always use the pressure regulator and hose assembly provided with the appliance to connect to a LP gas cylinder Never connect to an unregulated LP gas supply Hand turn the manual gas control valve Never ...

Page 7: ...3 Regular maintenance of the hose and regulator a Inspect the hose before each use of the fire table If the hose shows signs of cracks abrasions cuts or damage of any kind do not operate the appliance Fix or replace the hose as required before using the appliance Use only replacement parts from the manufacturer b Inspect the seal inside the v a l v e on the LP gas cylinder when replacing the cylin...

Page 8: ...List Item Quantity 1 Table 1 2 LP Gas Regulator and Hose 1 3 AAA Battery Optional 1 4 Lava Rock or Fire Glass Optional 1 box 5 Vinyl Cover 6 Tank Seat 7 Table Lid Optional 1 Optional 1 Optional 1 4 7 3 5 6 8 ...

Page 9: ...it into the fire or trash Please treat it as hazardous waste and recycle properly Place lava rock by hand Do NOT dump bag out into tray to avoid clogging the burner with dust Put Lava Rock or Fire glass inside and around the burner as shown Make sure that you do not block the igniter box with lava rock to ensure proper ignition 9 ...

Page 10: ...ing the LP Gas Tank Check to make sure there is no debris in the head of the LP gas tank or in the head of the regulator valve Make sure you check the burner and burner ports as well Connect gas line to tank by turning knob clockwise Hand tighten only Make sure that there are no kinks or bends in the hose and that it is placed out of any pathways where people will not trip on it 10 ...

Page 11: ...es round burner 13 inches round burner Nominal heat input 12kW 946g h 13 2kW 1040g h Serial number 2018121070RDR 01 Pin code 2531CS 0167 Electrical data N A New weight 42 kg GAS CATEGORY GAS TYPE AND PRESSURE Injector size mm DESTINATION COUNTRIES 10inch bunrer 13inch burner I3 28 30 37 G30 28 30 mbar G31 37mbar 1 74 1 86 BE FR IT LU IE GB GR PT ES CY CZ LT SK CH SI LV I3B P 30 G30 G31 or their mi...

Page 12: ...y solution and proceed Check for leaks at these locations WARNING DO NOT use an open fl ame to check for leaks DO NOT smoke while testing the unit NEVER test the unit indoors Leak checks must be preformed any time the gas cylinder is replaced Inspecting This outdoor fire table must be inspected regularly to ensure that the product is safe to use and to extend product life WARNING DO NOT inspect thi...

Page 13: ...s turn control knob to the Off position and turn gas off at the source wait 5 minutes until gas has cleared and repeat lighting procedure 9 Adjust the flame to the desired height with the control knob Using a Long Match or Lighter 1 Prior to lighting use a shovel to move the lava rocks for access to the burner 2 Wearing heat resistant gloves position the burning long match or burning butane lighter n...

Page 14: ...nts 3 For stubborn stains and discoloration use 3M Stainless Steel Cleaner and Polish Allchem Concentrated Cleaner Samae Twinkle Cameo Copper Cleaner Liquid Nu Steel Copper s or Revere Stainless Steel Cleaner apply using a soft cloth in the same direction of the polish lines 4 NOTE Even the finest cleaning powders can scratch or burnish a mill rolled finish On polished finishes rubbing or wiping s...

Page 15: ...r ignition make sure the igniter pin is properly positioned and connected The Igniter Pin must be 3 mm 1 8 away from the burn tube Below Left The ignition wires must be fully inserted into the ignitor box The ignitor box is located next to the control valve under the unit Thermocouple 3mm Igniter Pin If wires are too close or tangled they could short Make sure they are spaced apart from each other...

Page 16: ...on the following page Possible Cause 2 Coupling nut and regulator not fully connected Turn the coupling nut about one half to three fourths a turn until you feel a solid stop Do not use tools tighten by hand only Possible Cause 3 Obstruction of gas flow Check for bent or kinked hose Possible Cause 4 Spider webs or insect nest in the venturi Clean the venturi Possible Cause 5 Burner ports clogged o...

Page 17: ...re clogged or blocked Clean burner ports Do this by inserting a paperclip into each of the burner ports to ensure they are not clogged WARNING Make sure burner is not on and has had sufficient time to cool before touching it Burner Ports Problem Flame blow out Possible Cause 1 High or gusting winds Increase flame to HIGH setting Possible Cause 2 Low on LP gas Replace or refill LP gas tank Possible ...