INSPECTIONS, MAINTENANCE AND SERVICE
INSPECTIONS AND MAINTENANCE
Check periodically that:
1.
The heater is sufficiently powered and the connections are in good condition and clean.
2.
The exhaust fumes can leave the heater freely.
3.
There are no leaks in the fuel lines.
4.
The fuel filter and tank are in good condition.
5.
The unit and its environment is clean (dust-free).
If you have any reason to suspect that your unit is experiencing reduced performance, check:
1.
The fuel should move about 25mm/pulse
2.
The fuel consumption at full power is approx. 210-230 ml/h.
3.
The fuel needle is clogged. Clean it by drilling with a 1.5mm drill bit or heating with a gas flame.
4.
The fuel line is blocked, for example, by thickened fuel. Isopropanol helps clear the blockage. It can
be forced through the hoses or pump e.g. with an injection syringe.
5.
Air leak in the fuel line, check the connections.
MAINENTANCE
The service hatch at the front of the unit can be used for servicing the fuel supply needle, the glow plug and
the ionisation sensor (flame detector). Other maintenance requires the removal of the stove.
1. Ionisation sensor
2. Supply needle
3. Glow plug
4. Combustion air
blower
6.