background image

3 / 8 

Safire cera22 Ceramic cooktop 

 

SF-Lämmitin Oy Tilhenkatu 1 20610 TURKU, FINLAND Tel. +358(0)2 244 3282   

www.safire.fi

  

01/2018 

 

 

Cooktops equipped with a heating blower lid 

-  The  thermostat  sensor  is  connected  to  terminal  block  X10.  The  electronics  automatically 

detect the installation of a thermostat sensor. When the blower lid is in the lower position, the 
power  control  of  the  control  panel  changes  to  temperature  control.  Please  note!  Disconnect 
the heater from the battery before connecting the thermostat sensor. 

The pump’s power cords are connected to terminal block X10. 
 

NOTE! 

Connect  all  wires  so  that  any  water  flowing  along  them  will  not  end  up  on  the  circuit 

board of the cooktop. 

 

 

SIRIUS CONTROL PANEL 

-  The control panel should be located in a dry, splash-proof location so that it is easy to see and 

use and there is no risk of accidental starting. 

-  The body of the control panel is first fixed with 2-sided tape, e.g. to the cabinet wall, and the 

cable is passed through the wall. Lastly, attach the cover plate with 2-sided tape. 

-  The cable of the control panel is connected to the circuit board of the cooktop. The main 

power is connected after the control panel is connected. 

 

 

 
USAGE 
 
 

COMMISSIONING 
 

Make sure that: 
 

o

 

The tank, tank connection and fuel line are properly installed.

 

o

 

The stove is securely attached.

 

o

 

The exhaust system is properly installed and there are no flammable substances 
or objects in the vicinity of the exhaust passage.

 

o

 

There are no flammable substances or objects on the stove.

 

 
 

FUEL 
 

The recommended fuel is HVO-based winter grade diesel (summer grade in summer), e.g. 
Neste MY or Pro Diesel, and in extremely cold conditions paraffin oil (Neste or Polaric). At the 
end of the season, it is recommended that you leave the winter grade diesel or paraffin oil in 
the fuel line so that there are no start-up problems at the beginning of the next season. Poor 
fuel quality is the most common cause of malfunctions in stoves and heaters. 

Note that the recommended fuel storage times are not very long these days, at most about 
half a year. 

Only isopropanol (2%) can be used as an additive to remove any water and clean the fuel line. 

 

 

 
 
 

Summary of Contents for cera22

Page 1: ...e cooktop by providing ventilation openings of approximately 100 cm2 10x10cm on the top and bottom of the installation space Before mounting the cooktop it is recommended to install the flue gas pipe...

Page 2: ...mp to rigidly to the structures as this may cause resonation ELECTRICAL CONNECTIONS The cooktop operates at 12V DC It is recommended to use the 12V auxiliary battery if the boat is equipped with one A...

Page 3: ...ugh the wall Lastly attach the cover plate with 2 sided tape The cable of the control panel is connected to the circuit board of the cooktop The main power is connected after the control panel is conn...

Page 4: ...itches off The power supply of the cooktop must not be cut off before the aftercooling phase has ended approx 8 minutes e g by using the main switch If the power is turned off during the aftercooling...

Page 5: ...ing No 6 convection blower fault indicates that there is a fault in the main blower blower lid or its wiring No 7 undervoltage fault indicates undervoltage The power cords are too long or thin the bat...

Page 6: ...xperiencing reduced performance check 1 The fuel should move about 25mm pulse 2 The fuel consumption at full power is approx 210 230 ml h 3 The fuel needle is clogged Clean it by drilling with a 1 5mm...

Page 7: ...lower ring of the hat over the locking Do not damage the outer edge of the burner 5 Clean the burner e g by scraping with a screwdriver If necessary drill the guide tube of the supply needle with a 3...

Page 8: ...8 8 Safire cera22 Ceramic cooktop SF L mmitin Oy Tilhenkatu 1 20610 TURKU FINLAND Tel 358 0 2 244 3282 www safire fi 01 2018 7 8 9 10...

Reviews: