STARTING AND INDICATORS 
 

The unit is turned on by pressing the power switch for about one second. The status LED 
lights up green when the power is on. 

The flame indicator flashes green during start-up and lights up continuously when a flame is 
detected. 

The decimal point on the numeric display blinks with the control pulses to the pump. 

In stove mode, the power (1-10) is adjusted with the arrow keys and the numeric display. The 
setting is displayed by pressing the arrow key once. 

When the blower lid is used (heating mode), select power or temperature with the MODE 
buttons. The thermostat automatically controls the power when the temperature setting is 
selected. 

 
 
 
 
 
 
 

 

TURNING OFF 
 

The unit is switched off by pressing the power switch. The pump stops and the stove switches 
to aftercooling mode and then switches off.

 

The power supply of the cooktop must not be 

cut off before the aftercooling phase has ended (approx. 8 minutes) e.g. by using the 
main switch.

 

If the power is turned off during the aftercooling period, the fault state (fault code A) must be 
acknowledged by pressing the MODE button. Disconnect the power from the main switch if 
the unit is not used for an extended period of time. 

 
 
 

POSSIBLE ISSUES 

 

 

If the 

green status indicator

 does not light up during start-up, the stove is not receiving 

electricity.

 

If the 

flame indicator 

is not lit after the start-up process (approx. 6.5 minutes), the device 

enters the aftercooling phase and turns off. The reason for this could be an empty fuel system 
or poor-quality fuel. A new start-up attempt can be made if other problems are not found. After 
two unsuccessful attempts, the cause of the problem should be identified to prevent the fuel 
from escaping from the burner. 

As the heater is running, if the green flame indicator dims and the fault indicator is lit, it is 
usually a sign of an empty fuel tank, a disruption in the fuel supply or e.g. a power problem. 
Check the unit for issues. 

 
 

 

 
 
 
 
 
 

Summary of Contents for cera22

Page 1: ...e cooktop by providing ventilation openings of approximately 100 cm2 10x10cm on the top and bottom of the installation space Before mounting the cooktop it is recommended to install the flue gas pipe...

Page 2: ...mp to rigidly to the structures as this may cause resonation ELECTRICAL CONNECTIONS The cooktop operates at 12V DC It is recommended to use the 12V auxiliary battery if the boat is equipped with one A...

Page 3: ...ugh the wall Lastly attach the cover plate with 2 sided tape The cable of the control panel is connected to the circuit board of the cooktop The main power is connected after the control panel is conn...

Page 4: ...itches off The power supply of the cooktop must not be cut off before the aftercooling phase has ended approx 8 minutes e g by using the main switch If the power is turned off during the aftercooling...

Page 5: ...ing No 6 convection blower fault indicates that there is a fault in the main blower blower lid or its wiring No 7 undervoltage fault indicates undervoltage The power cords are too long or thin the bat...

Page 6: ...xperiencing reduced performance check 1 The fuel should move about 25mm pulse 2 The fuel consumption at full power is approx 210 230 ml h 3 The fuel needle is clogged Clean it by drilling with a 1 5mm...

Page 7: ...lower ring of the hat over the locking Do not damage the outer edge of the burner 5 Clean the burner e g by scraping with a screwdriver If necessary drill the guide tube of the supply needle with a 3...

Page 8: ...8 8 Safire cera22 Ceramic cooktop SF L mmitin Oy Tilhenkatu 1 20610 TURKU FINLAND Tel 358 0 2 244 3282 www safire fi 01 2018 7 8 9 10...