ERROR MESSAGES 

 

 

No. 1 (overheating fault)

 indicates overheating.  

The cause of overheating is often, for example, insufficient ventilation at the stove installation site. 

No. 2 (ionisation fault)

 indicates that the ionisation electrode is faulty or sooty. The fault also comes up if the sensor is 

shorted with the heater frame. 

No. 3 (fire detection fault)

 means that the heater has shut down due to the lack of a flame. Usually, this means that the 

fuel has run out or the fuel system is clogged. However, if the flame is visible, there may be a problem in the 
electronics. 

No. 4 (glow fault)

 indicates that the glow plug is at fault: the connector is disconnected, the plug is broken or its wire is 

faulty. 

No. 5 (combustion fan fault)

 indicates that there is a fault in the combustion air fan or its wiring. 

No. 6 (convection blower fault)

 indicates that there is a fault in the main blower (blower lid) or its wiring. 

No. 7 (undervoltage fault)

 indicates undervoltage. The power cords are too long or thin, the battery is low or 

connections have oxidised. 

No. 8 (pump fault)

 indicates that the circuit of the pump is not closed. A cable is broken or disconnected. 

No. 9 (circulating air fault)

 indicates that there is a fault in the circulating air sensor or its wiring. 

A

 indicates that the heater has not shut down normally during the last shutdown. There has been either a rapid voltage 

drop or the power has been disconnected from the main switch before the aftercooling has ended.  

 

The 

decimal on the display

 blinks with the pulses of the pump. 

The pump is not powered (fault code 8) if the decimal does not blink, the pump does not make a clicking sound and 
there is no other fault present. The fault is either in the wiring of the pump, the coil or the circuit board. 
If the decimal blinks while the pump does not make a clicking sound, and the wires are not in a short circuit, the pump 
is faulty; usually due to fuel thickening.

 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for cera22

Page 1: ...e cooktop by providing ventilation openings of approximately 100 cm2 10x10cm on the top and bottom of the installation space Before mounting the cooktop it is recommended to install the flue gas pipe...

Page 2: ...mp to rigidly to the structures as this may cause resonation ELECTRICAL CONNECTIONS The cooktop operates at 12V DC It is recommended to use the 12V auxiliary battery if the boat is equipped with one A...

Page 3: ...ugh the wall Lastly attach the cover plate with 2 sided tape The cable of the control panel is connected to the circuit board of the cooktop The main power is connected after the control panel is conn...

Page 4: ...itches off The power supply of the cooktop must not be cut off before the aftercooling phase has ended approx 8 minutes e g by using the main switch If the power is turned off during the aftercooling...

Page 5: ...ing No 6 convection blower fault indicates that there is a fault in the main blower blower lid or its wiring No 7 undervoltage fault indicates undervoltage The power cords are too long or thin the bat...

Page 6: ...xperiencing reduced performance check 1 The fuel should move about 25mm pulse 2 The fuel consumption at full power is approx 210 230 ml h 3 The fuel needle is clogged Clean it by drilling with a 1 5mm...

Page 7: ...lower ring of the hat over the locking Do not damage the outer edge of the burner 5 Clean the burner e g by scraping with a screwdriver If necessary drill the guide tube of the supply needle with a 3...

Page 8: ...8 8 Safire cera22 Ceramic cooktop SF L mmitin Oy Tilhenkatu 1 20610 TURKU FINLAND Tel 358 0 2 244 3282 www safire fi 01 2018 7 8 9 10...

Reviews: