background image

 

SAFIRE 2400Di, 2600Di, 3200Di and 3600Di Diesel / fuel oil heaters 

1

 

 

USAGE, INSTALLATION AND MAINTENANCE 

 

 

January 2012 

SF - Lämmitin Oy

 Tilhenkatu 1 20610 Turku Finland Puh./Fax +358(0)2-2443282 

 

!

 

 

 

 

 

A heater kit contains: 

 

• Heater, mounting bracket 

• Fuel hose (3 meters), pump, a fuel tank connection to a standard tank (30 litres) 

• Power supply cable (4 meters), control panel cable (10 meters) 

• Mounting screws, clamps 

• Accessories indicated on the package: Control panel or GENIUS control panel, temperature sensor for the 

thermostat, exhaust outlet through the hull. 

 

 

PLACING THE HEATER 

 

Place the heater so that at least a part of the air to be warmed can be taken outside. This will allow good 

ventilation and drying effect.  

When choosing a place for the heater remember that warm air hoses placed outside the heated space will 

lose plenty of heat. Minimize their length and isolate them carefully. It is more economic to place the heater 

close to the space to be heated and use a separate fresh air inlet. You don’t have to isolate the warm air 

hoses inside (f. ex. under the bed); the hoses function as “radiators” for they dry the space and balance the 

temperature differences.  

Remember also that as the heater blows warm air inside, an equivalent amount of air must be let out f. ex. 

through a ventilator or return to the heater as circulating air. 

Maintenance is usually easiest to perform when the heater is removed from its bracket. If the heater is 

examined on its place, place the heater so that the led indicators near the fresh air inlet and the control 

display are in sight. 

Place the heater so that the heater is above the tank’s fuel level. The heater will however not be damaged if 

the filler hole of the tank and thereby the fuel level temporarily rises above the heater.  

The fuel hose can be lengthened between the pump and the tank.     

Summary of Contents for 2400Di

Page 1: ...e plenty of heat Minimize their length and isolate them carefully It is more economic to place the heater close to the space to be heated and use a separate fresh air inlet You don t have to isolate the warm air hoses inside f ex under the bed the hoses function as radiators for they dry the space and balance the temperature differences Remember also that as the heater blows warm air inside an equ...

Page 2: ... pump Attach the fuel hoses carefully and protect them from heat or mechanical strain Exhaust outlet Exhaust is led out and combustion air taken in through hull with a coaxial exhaust outlet For installing the outlet you need to make one Ø 50 mm hole and four 5 5 mm holes use the outlet end as a model Cut the inner pipe a bit too long so that it can t slip from its place Bend the exhaust outlet ho...

Page 3: ...at least 6 mm 2 thick NB The housing of the heater is galvanic connected to the minus pole of the battery You can connect a separate main switch to the heater and a 20A time delay fuse near the battery there is a 20A main time delay fuse F1 on the circuit board Be careful not to connect the wires wrong This would melt the 7 5A fuse F2 which protects the electronics Connect the thermostat s sensor ...

Page 4: ...ifreeze for diesel engines to the fuel If you don t use the heater in the winter and store it in a cold place use paraffin oil the last time you use the heater and leave the fuel hoses full paraffin oil has a low cloud point Paraffin oil will protect the hose from freeze CONTROLLING THE HEATER AND INDICATOR LEDS Basic control panel Start turn the switch to position HEAT ON Ventilation turn the swi...

Page 5: ... or the temperature Choose menu items with arrow keys accept with OK If you desire extra strong ventilation choose DRYING VENTILATE On this mode the heater takes more fresh air this improves the drying effect while the heating power is low practical f ex in the summer when the air is damp but not very cold Return to the main menu with BACK NB All selections are not allowed in every mode STARTING T...

Page 6: ...ion the error code on the circuit board display is 3 NB If you have turned off the heater after some malfunction you can see the latest error code on the display again by turning the switch to the position VENT the number of the latest malfunction which caused the heater to turn off shows on the display ERROR CODE NUMBERS ON THE CIRCUIT BOARD DISPLAY Number 1 Overheating Overheating is usually cau...

Page 7: ...ith the 3600Di heater is180 pulses min and 50 pulses min on minimum power 3200Di heater is 160 pulses min and 50 pulses min on minimum power 2600Di heater is 130 pulses min and 50 pulses min on minimum power with the 2400Di heater 120 pulses min on maximum power and 50 pulses min on minimum power If the heater gets too much fuel the combustion may be impure and cause risk of overheating If the ove...

Page 8: ...an and then scraping it off f ex with a screwdriver 8 If necessary change the backing 6 The backing stays on its place with a locking spring 7 9 Assemble in an opposite order Make sure that the burner is on its place in a right position Use the glow plug to align the burner Check also the position of the casing pipe of the fuel pipe CLEANING THE FLAME SENSOR ELECTRODE Error code number 2 in the ci...

Page 9: ...n anti freeze for gasoline engines and truck air brakes through the pump OPENING AND CLEANING THE PUMP 1 Release the hose connectors from the pump 2 Release the wires from the pump 3 Remove the connector strip 8 so that it rests on the filaments of the spool 4 Unscrew the iron housing 1 of the pump and remove it 5 Pull the upper end 3 of the pump out of the spool 4 the piston 9 and the spring 10 a...