7.0 INSPECTION FREQUENCY
Type of Use
Application Examples
Conditions of Use
Inspection Frequency
Competent Person
Infrequent to Light
Rescue and Confined Space,
Factory Maintenance
Good Storage Conditions, Indoor
or Infrequent Outdoor Use, Room
Temperature, Clean Environments
Annually
Moderate to Heavy
Transportation, Residential
Construction, Utilities, Warehouse
Fair Storage Conditions, Indoor and
Extended Outdoor Use, All Temperatures,
Clean or Dusty Environments
Semi-Annually to Annually
Severe to Continuous
Commercial Construction, Oil and
Gas, Mining
Harsh Storage Conditions, Prolonged
or Continuous Outdoor Use, All
Temperatures, Dirty Environment
Quarterly to Semi-Annually
TABLE 3 - INSPECTION SCHEDULE PER ANSI Z359.14-2021
TABLE 4 - MATERIALS
TABLE 5 - PERFORMANCE REQUIREMENTS PER ANSI Z359.14-2021
(CLASS 1 SRL)
9.0 SPECIFICATIONS
8.0 PURPOSE
Self Retracting Lifelines are used as part of a PFAS. Safewaze SRLs are designed to safely arrest the user in a fall from height, while minimizing forces
associated with what can be an extremely violent event. Safewaze SRLs are authorized for use with Horizontal Lifeline Systems but must NEVER be used
as the lifeline constituent of an HLL System. Safewaze Class 1 SRLs must be used in overhead applications only and are not authorized for use below the Dorsal
D-ring. Safewaze Class 2 SRLs are designed for both overhead and below Dorsal D-ring use. Maximum allowable Free Fall for Class 1 SRLs is 2 ft..
1.
Authorized Person:
A person assigned by the employer to perform duties at a location where such person will be exposed to a fall hazard.
2.
Rescuer:
Person or persons other than the rescue subject acting to perform an assisted rescue by operation of a rescue system.
Either the Authorized Person¹ (User) or the Rescuer² must inspect this equipment prior to each use. The Inspection table (Table 3), should be used to determine
proper inspection frequency. The Inspection Form (Page 15) describes proper inspection procedures. The Competent Person should record inspection results in
the Inspection Form and retain a copy for records. (NOTE: User is advised to make copies of the Inspection Form on (Page 15) of this manual prior to filling out
the form for the first time). Copies of the Inspection Form can be used for later Inspections. Annual inspections by a Competent Person other than the user must
be recorded in the Inspection Log (Page 16).
NOTE:
Special rescue measures may be required for a fall over an edge.
Northstar Classic SRL Minimum Breaking Strength
3,600 lbs. (1632.9 kg)
Working Temperature Range
-35°F (-37°C) to 130°F (54°C)
Average Arresting Force
≤ 1,350 lbs. (612.3 kg)
Maximum Arresting Force
≤ 1,800 lbs. (816.5 kg)
Maximum Arrest Distance
42 in. (106.6 cm)
SRLs documented in this instruction manual meet the following Arrest Force and Arrest Distance maximums when tested in accordance with ANSI Z359.14-2021.
These calculations are based upon overhead anchorage of the SRL.
HOUSING
Nylon and Glass Fiber
DRUM
Aluminum
LIFELINE
3/16” Galvanized Steel Cable or UHMPE Webbing
SWIVEL
Aluminum
FASTENERS
Aluminum / Steel / Stainless Steel
LOCKING PAWLS
Brass
MAIN SHAFT
Stainless Steel
SPRINGS
Stainless Steel