 7.0  INSPECTION FREQUENCY

Type of Use

Application Examples

Conditions of Use

Inspection Frequency

Competent Person

Infrequent to Light

Rescue and Confined Space, 

Factory Maintenance

Good Storage Conditions, Indoor

or Infrequent Outdoor Use, Room

Temperature, Clean Environments

Annually

Moderate to Heavy

Transportation, Residential 

Construction, Utilities, Warehouse

Fair Storage Conditions, Indoor and

Extended Outdoor Use, All Temperatures,

Clean or Dusty Environments

Semi-Annually to Annually

Severe to Continuous

Commercial Construction, Oil and 

Gas, Mining

Harsh Storage Conditions, Prolonged

or Continuous Outdoor Use, All

Temperatures, Dirty Environment

Quarterly to Semi-Annually

TABLE 3 - INSPECTION SCHEDULE PER ANSI Z359.14-2021 

TABLE 4 - MATERIALS 

TABLE 5 - PERFORMANCE REQUIREMENTS PER ANSI Z359.14-2021

(CLASS 1 SRL) 

 9.0  SPECIFICATIONS

 8.0  PURPOSE

Self Retracting Lifelines are used as part of a PFAS.   Safewaze SRLs are designed to safely arrest the user in a fall from height, while minimizing forces  

associated with what can be an extremely violent event.   Safewaze SRLs are authorized for use with Horizontal Lifeline Systems but must NEVER be used  

as the lifeline constituent of an HLL System.  Safewaze Class 1 SRLs must be used in overhead applications only and are not authorized for use below the Dorsal 

D-ring.  Safewaze Class 2 SRLs are designed for both overhead and below Dorsal D-ring use.  Maximum allowable Free Fall for Class 1 SRLs is 2 ft.. 

 

1.  

Authorized Person:

 A person assigned by the employer to perform duties at a location where such person will be exposed to a fall hazard.

2.  

Rescuer: 

Person or persons other than the rescue subject acting to perform an assisted rescue by operation of a rescue system.

Either the Authorized Person¹ (User) or the Rescuer² must inspect this equipment prior to each use.  The Inspection table (Table 3), should be used to determine 

proper inspection frequency.  The Inspection Form (Page 15) describes proper inspection procedures.  The Competent Person should record inspection results in 

the Inspection Form and retain a copy for records. (NOTE: User is advised to make copies of the Inspection Form on (Page 15) of this manual prior to filling out 

the form for the first time).  Copies of the Inspection Form can be used for later Inspections.  Annual inspections by a Competent Person other than the user must 

be recorded in the Inspection Log (Page 16). 

NOTE:

 Special rescue measures may be required for a fall over an edge.

Northstar Classic SRL Minimum Breaking Strength

3,600 lbs. (1632.9 kg)

Working Temperature Range

-35°F (-37°C) to 130°F (54°C)

Average Arresting Force

≤ 1,350 lbs. (612.3 kg)

Maximum Arresting Force

≤ 1,800 lbs. (816.5 kg)

Maximum Arrest Distance

42 in. (106.6 cm)

SRLs documented in this instruction manual meet the following Arrest Force and Arrest Distance maximums when tested in accordance with  ANSI Z359.14-2021.  

These calculations are based upon overhead anchorage of the SRL.

HOUSING

Nylon and Glass Fiber

DRUM

Aluminum

LIFELINE

3/16” Galvanized Steel Cable or UHMPE Webbing

SWIVEL

Aluminum

FASTENERS

Aluminum / Steel / Stainless Steel

LOCKING PAWLS

Brass

MAIN SHAFT

Stainless Steel

SPRINGS

Stainless Steel

Summary of Contents for NORTHSTAR CLASSIC SRL

Page 1: ...acturer s instructions as required by ANSI Z359 14 2021 and should be used as part of an employee training program as required by OSHA Copyright Safewaze 2022 SRL Instruction Manual 220 00084 ANSI Z35...

Page 2: ...IN REQUIRED FALL CLEARANCE 8 9 11 0 SWING FALLS 10 12 0 FALL PROTECTION AND RESCUE PLAN 11 13 0 NORMAL OPERATIONS 11 14 0 COMPATIBILITY OF COMPONENTS 11 15 0 COMPATIBILITY OF CONNECTORS 11 12 16 0 USE...

Page 3: ...ems or both that may affect or interfere with the safe function of each other DO NOT alter equipment DO NOT misuse equipment User must have a written Rescue Plan and means at hand to implement it when...

Page 4: ...e E y e C a r a b i n e r A L U S n a p H o o k F S E X 3 1 3 C a b M o u n t B r a c k e t S o f t L o o p I n t e g r a t e d B W B 1 0 1 4 B W B 9 0 1 2 B W B 9 0 1 3 B W B FS FSP1420 W 1 S 20 UHMP...

Page 5: ...anual Class 1 and 2 Class 1 Self retracting devices which shall be used only on overhead anchorages and shall be subjected to a maximum free fall of 2 feet 0 6 m or less in practical application Class...

Page 6: ...ll Clearance Figure 2 Illustrates a Fall Clearance Calculation Fall Clearance FC is the total combined values of Free Fall FF Deceleration Distance DD and a Safety Factor SF Safety Factor calculations...

Page 7: ...thorized Person A person assigned by the employer to perform duties at a location where such person will be exposed to a fall hazard 2 Rescuer Person or persons other than the rescue subject acting to...

Page 8: ...ance for each unit in prescribed condition testing with 0 offset EXAMPLE The FS FSP1215 G has Actual Arrest Distances of 16 17 17 and 34 during Ambient Wet Hot and Cold testing respectively By using t...

Page 9: ...he anchorage connector to arrest a fall before the user strikes the ground or an obstruction Figure 2 illustrates a typical Fall Clearance calculation based on the ANSI Z359 14 2021 prescribed Maximum...

Page 10: ...3 5 2 2 4 3 5 5 6 1 4 6 8 7 2 10 3 11 1 18 6 7 10 8 2 12 3 4 13 15 17 1 19 20 22 24 7 9 12 11 3 14 18 4 6 16 8 20 18 20 2 22 24 25 6 3 4 27 21 23 25 27 29 31 18 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0...

Page 11: ...ECTORS HAVE ADDITIONAL REQUIREMENTS CONTACT SAFEWAZE WITH QUESTIONS Connectors are compatible with connecting elements when they have been designed to work together in such a way that their sizes and...

Page 12: ...mmediately Equipment must then be serviced See Section 18 if applicable or disposed of See Section 19 16 0 USE 16 1 OPERATION 16 2 AFTER A FALL A full body harness must be worn when using Safewaze SRL...

Page 13: ...tracting back into the housing DO NOT USE HEAT to dry web lifeline IMPORTANT If the lifeline comes in contact with acids or other caustic chemicals remove the SRL from service and wash with water and...

Page 14: ...horizontal lifelines Adhere to the hierarchy of controls in Z359 2 Class 1 Anchor at or above dorsal D ring Working length 50 ft 15 24 m Material 3 16 in galvanized steel cable steel hardware nylon a...

Page 15: ...ok Body Rivets Corrosion Pitting Nicks CONNECTORS PASS FAIL NOTE Termination Stitch Splice or Swage Cuts Fraying Broken Stitching Excessive Wear Cable Separating Bird Caging Entire Length Retracts Smo...

Page 16: ...waze 2022 Page 16 Date Inspection Items Noted Corrective Action Initials INSPECTION LOG Safewaze 225 Wilshire Ave SW Concord NC 28025 PHONE 1 800 230 0319 FAX 1 704 262 9051 WEB safewaze com EMAIL inf...

Reviews: