background image

Copyright Safewaze 2022

Page 8

Personal Fall Arrest: 

Safewaze Class 1 SRLs can be used as part of a complete Personal Fall Arrest System (PFAS) for a maximum of one user.  Only one user 

may be connected to an SRL.  Avoid sharp and/or abrasive edges. If contact with an abrasive surface is unavoidable, proper edge protection must be used.  The 

structure utilized for attachment must be capable of withstanding a load of 5,000 lbs. in all directions permitted by the system. The maximum allowable free fall 

is 2 ft.    

 10.0  ACTUAL ARREST DISTANCE / MINIMUM REQUIRED FALL CLEARANCE

Minimum Required Fall Clearance:

Safewaze SRLs are tested in accordance with ANSI Z359.14-2021 conditioning test protocols.  Table 6 reflects the actual performance of each unit in the 

Northstar Classic SRL series when subjected to Ambient, Wet, Hot, and Cold testing.  The Fall Clearance specifications in Table 8 of this manual reflect the 

 

ANSI Z359.14-2021 Maximum Arrest Distance allowance of 42”.  Actual Arrest Distances for each unit in the Northstar Classic SRL series are indicated below.  

These Actual Arrest Distances are typically lower than the 42” maximum as specified per ANSI. In certain instances this may allow for a Qualified Person to adjust 

Minimum Required Fall Clearances indicated in Table 8.

The Minimum Required Fall Clearance distances indicated in Table 7 are based upon Ambient, Wet, Hot, and Cold testing results for each unit in the Northstar 

Classic SRL series.  Fall Clearances indicated in Table 7 are calculated using the greatest Actual Arrest Distance out of the four tests performed on each model.

Table 6 indicates the specific arrest distance for each unit in prescribed condition testing with 0’ offset.  

EXAMPLE:  

The FS-FSP1215-G has Actual Arrest Distances of 16”, 17”, 17”, and 34” during Ambient, Wet, Hot, and Cold testing respectively.

By using the greatest distance (Cold=34”) out of the four tests performed and inserting that value in Row B of the Chart in Figure 2, a Total Fall Clearance  

of 6’ 10” is required.  

Actual Arrest Distance (AD):

FIGURE 1 - CLASS 1 SRL AXES DIAGRAM

Y

X

Z

Z:

 

Minimum Required 

Fall Clearance From 

Walking/Working Surface 

X:

 SRL Anchorage Height

       Above Dorsal D-ring

Y:

 Lateral Offset 

      Distance

Class 1 Axes Diagram

TABLE 7 - MINIMUM REQUIRED FALL CLEARANCE

Model #

Ambient

Wet

Hot

Cold

FS-FSP1215-G

16” (40.6 cm)

17” (43.2 cm)

17” (43.2 cm)

34” (86.4 cm)

FS-FSP1215-SS

16” (40.6 cm)

17” (43.2 cm)

17” (43.2 cm)

34” (86.4 cm)

FS-FSP1220-G

23” (58.4 cm)

26” (66 cm)

29” (73.7 cm)

39” (99.1 cm)

FS-FSP1220-SS

23” (58.4 cm)

26” (66 cm)

29” (73.7 cm)

39” (99.1 cm)

FS-FSP1230-G

30” (76.2 cm)

36” (91.4 cm)

24” (61 cm)

37” (94 cm)

FS-FSP1230-SS

30” (76.2 cm)

36” (91.4 cm)

24” (61 cm)

37” (94 cm)

FS-FSP1250-G

24” (61 cm)

39” (99.1 cm)

32” (1.3 cm)

41” (104.1 cm)

FS-FSP1250-SS

24” (61 cm)

39” (99.1 cm)

32” (1.3 cm)

41” (104.1 cm)

FS-FSP1265-G

24” (61 cm)

22” (56 cm)

19” (48.3 cm)

35” (89 cm)

FS-FSP1420-W

35” (88.9 cm)

41” (104.1 cm)

41” (104.1 cm)

39” (99.1 cm)

FS-EX1080-G

40” (101.6 cm)

38” (96.5 cm)

40” (101.6 cm)

41” (104.1 cm)

FS-EX10-100-G

40” (101.6 cm)

38” (96.5 cm)

40” (101.6 cm)

41” (104.1 cm)

TABLE 6 - ACTUAL ARREST DISTANCES 

NOTE:

  A Qualified Person must determine if MRFCs can be adjusted based upon actual jobsite atmospheric conditions or additional 

factors.  

Model #

MRFC

Model #

MRFC

Model #

MRFC

Model #

MRFC

FS-FSP1215-G

6’ 10” (2.1 m)

FS-FSP1220-SS

7’ 4” (2.2 m)

FS-FSP1250-G

7’ 5” (2.3 m)

FS-FSP1420-W

7’ 5” (2.3 m)

FS-FSP1215-SS

6’ 10” (2.1 m)

FS-FSP1230-G

7’ 1” (2.2 m)

FS-FSP1250-SS

7’ 5” (2.3 m)

FS-EX1080-G

8’ 5” (2.6 m)

FS-FSP1220-G

7’ 4” (2.2 m)

FS-FSP1230-SS

7’ 1” (2.2 m)

FS-FSP1265-G

6’ 11” (2.1 m)

FS-EX10-100-G

8’ 5” (2.6 m)

Summary of Contents for NORTHSTAR CLASSIC SRL

Page 1: ...acturer s instructions as required by ANSI Z359 14 2021 and should be used as part of an employee training program as required by OSHA Copyright Safewaze 2022 SRL Instruction Manual 220 00084 ANSI Z35...

Page 2: ...IN REQUIRED FALL CLEARANCE 8 9 11 0 SWING FALLS 10 12 0 FALL PROTECTION AND RESCUE PLAN 11 13 0 NORMAL OPERATIONS 11 14 0 COMPATIBILITY OF COMPONENTS 11 15 0 COMPATIBILITY OF CONNECTORS 11 12 16 0 USE...

Page 3: ...ems or both that may affect or interfere with the safe function of each other DO NOT alter equipment DO NOT misuse equipment User must have a written Rescue Plan and means at hand to implement it when...

Page 4: ...e E y e C a r a b i n e r A L U S n a p H o o k F S E X 3 1 3 C a b M o u n t B r a c k e t S o f t L o o p I n t e g r a t e d B W B 1 0 1 4 B W B 9 0 1 2 B W B 9 0 1 3 B W B FS FSP1420 W 1 S 20 UHMP...

Page 5: ...anual Class 1 and 2 Class 1 Self retracting devices which shall be used only on overhead anchorages and shall be subjected to a maximum free fall of 2 feet 0 6 m or less in practical application Class...

Page 6: ...ll Clearance Figure 2 Illustrates a Fall Clearance Calculation Fall Clearance FC is the total combined values of Free Fall FF Deceleration Distance DD and a Safety Factor SF Safety Factor calculations...

Page 7: ...thorized Person A person assigned by the employer to perform duties at a location where such person will be exposed to a fall hazard 2 Rescuer Person or persons other than the rescue subject acting to...

Page 8: ...ance for each unit in prescribed condition testing with 0 offset EXAMPLE The FS FSP1215 G has Actual Arrest Distances of 16 17 17 and 34 during Ambient Wet Hot and Cold testing respectively By using t...

Page 9: ...he anchorage connector to arrest a fall before the user strikes the ground or an obstruction Figure 2 illustrates a typical Fall Clearance calculation based on the ANSI Z359 14 2021 prescribed Maximum...

Page 10: ...3 5 2 2 4 3 5 5 6 1 4 6 8 7 2 10 3 11 1 18 6 7 10 8 2 12 3 4 13 15 17 1 19 20 22 24 7 9 12 11 3 14 18 4 6 16 8 20 18 20 2 22 24 25 6 3 4 27 21 23 25 27 29 31 18 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0...

Page 11: ...ECTORS HAVE ADDITIONAL REQUIREMENTS CONTACT SAFEWAZE WITH QUESTIONS Connectors are compatible with connecting elements when they have been designed to work together in such a way that their sizes and...

Page 12: ...mmediately Equipment must then be serviced See Section 18 if applicable or disposed of See Section 19 16 0 USE 16 1 OPERATION 16 2 AFTER A FALL A full body harness must be worn when using Safewaze SRL...

Page 13: ...tracting back into the housing DO NOT USE HEAT to dry web lifeline IMPORTANT If the lifeline comes in contact with acids or other caustic chemicals remove the SRL from service and wash with water and...

Page 14: ...horizontal lifelines Adhere to the hierarchy of controls in Z359 2 Class 1 Anchor at or above dorsal D ring Working length 50 ft 15 24 m Material 3 16 in galvanized steel cable steel hardware nylon a...

Page 15: ...ok Body Rivets Corrosion Pitting Nicks CONNECTORS PASS FAIL NOTE Termination Stitch Splice or Swage Cuts Fraying Broken Stitching Excessive Wear Cable Separating Bird Caging Entire Length Retracts Smo...

Page 16: ...waze 2022 Page 16 Date Inspection Items Noted Corrective Action Initials INSPECTION LOG Safewaze 225 Wilshire Ave SW Concord NC 28025 PHONE 1 800 230 0319 FAX 1 704 262 9051 WEB safewaze com EMAIL inf...