Personal Fall Arrest:
Safewaze Class 1 SRLs can be used as part of a complete Personal Fall Arrest System (PFAS) for a maximum of one user. Only one user
may be connected to an SRL. Avoid sharp and/or abrasive edges. If contact with an abrasive surface is unavoidable, proper edge protection must be used. The
structure utilized for attachment must be capable of withstanding a load of 5,000 lbs. in all directions permitted by the system. The maximum allowable free fall
is 2 ft.
10.0 ACTUAL ARREST DISTANCE / MINIMUM REQUIRED FALL CLEARANCE
Minimum Required Fall Clearance:
Safewaze SRLs are tested in accordance with ANSI Z359.14-2021 conditioning test protocols. Table 6 reflects the actual performance of each unit in the
Northstar Classic SRL series when subjected to Ambient, Wet, Hot, and Cold testing. The Fall Clearance specifications in Table 8 of this manual reflect the
ANSI Z359.14-2021 Maximum Arrest Distance allowance of 42”. Actual Arrest Distances for each unit in the Northstar Classic SRL series are indicated below.
These Actual Arrest Distances are typically lower than the 42” maximum as specified per ANSI. In certain instances this may allow for a Qualified Person to adjust
Minimum Required Fall Clearances indicated in Table 8.
The Minimum Required Fall Clearance distances indicated in Table 7 are based upon Ambient, Wet, Hot, and Cold testing results for each unit in the Northstar
Classic SRL series. Fall Clearances indicated in Table 7 are calculated using the greatest Actual Arrest Distance out of the four tests performed on each model.
Table 6 indicates the specific arrest distance for each unit in prescribed condition testing with 0’ offset.
EXAMPLE:
The FS-FSP1215-G has Actual Arrest Distances of 16”, 17”, 17”, and 34” during Ambient, Wet, Hot, and Cold testing respectively.
By using the greatest distance (Cold=34”) out of the four tests performed and inserting that value in Row B of the Chart in Figure 2, a Total Fall Clearance
of 6’ 10” is required.
Actual Arrest Distance (AD):
FIGURE 1 - CLASS 1 SRL AXES DIAGRAM
Y
X
Z
Z:
Minimum Required
Fall Clearance From
Walking/Working Surface
X:
SRL Anchorage Height
Above Dorsal D-ring
Y:
Lateral Offset
Distance
Class 1 Axes Diagram
TABLE 7 - MINIMUM REQUIRED FALL CLEARANCE
Model #
Ambient
Wet
Hot
Cold
FS-FSP1215-G
16” (40.6 cm)
17” (43.2 cm)
17” (43.2 cm)
34” (86.4 cm)
FS-FSP1215-SS
16” (40.6 cm)
17” (43.2 cm)
17” (43.2 cm)
34” (86.4 cm)
FS-FSP1220-G
23” (58.4 cm)
26” (66 cm)
29” (73.7 cm)
39” (99.1 cm)
FS-FSP1220-SS
23” (58.4 cm)
26” (66 cm)
29” (73.7 cm)
39” (99.1 cm)
FS-FSP1230-G
30” (76.2 cm)
36” (91.4 cm)
24” (61 cm)
37” (94 cm)
FS-FSP1230-SS
30” (76.2 cm)
36” (91.4 cm)
24” (61 cm)
37” (94 cm)
FS-FSP1250-G
24” (61 cm)
39” (99.1 cm)
32” (1.3 cm)
41” (104.1 cm)
FS-FSP1250-SS
24” (61 cm)
39” (99.1 cm)
32” (1.3 cm)
41” (104.1 cm)
FS-FSP1265-G
24” (61 cm)
22” (56 cm)
19” (48.3 cm)
35” (89 cm)
FS-FSP1420-W
35” (88.9 cm)
41” (104.1 cm)
41” (104.1 cm)
39” (99.1 cm)
FS-EX1080-G
40” (101.6 cm)
38” (96.5 cm)
40” (101.6 cm)
41” (104.1 cm)
FS-EX10-100-G
40” (101.6 cm)
38” (96.5 cm)
40” (101.6 cm)
41” (104.1 cm)
TABLE 6 - ACTUAL ARREST DISTANCES
NOTE:
A Qualified Person must determine if MRFCs can be adjusted based upon actual jobsite atmospheric conditions or additional
factors.
Model #
MRFC
Model #
MRFC
Model #
MRFC
Model #
MRFC
FS-FSP1215-G
6’ 10” (2.1 m)
FS-FSP1220-SS
7’ 4” (2.2 m)
FS-FSP1250-G
7’ 5” (2.3 m)
FS-FSP1420-W
7’ 5” (2.3 m)
FS-FSP1215-SS
6’ 10” (2.1 m)
FS-FSP1230-G
7’ 1” (2.2 m)
FS-FSP1250-SS
7’ 5” (2.3 m)
FS-EX1080-G
8’ 5” (2.6 m)
FS-FSP1220-G
7’ 4” (2.2 m)
FS-FSP1230-SS
7’ 1” (2.2 m)
FS-FSP1265-G
6’ 11” (2.1 m)
FS-EX10-100-G
8’ 5” (2.6 m)