background image

Copyright Safewaze 2022

Page 4

Part 

Number

SR

L C

las

s

Sin

gle

 Le

g (S

) / D

ua

l Le

g (D

)

W

ork

ing

 Le

ng

th (

ft.)

Life

lin

e M

ate

ria

l

Life

lin

e D

im

en

sio

ns (

in.)

Ho

usin

g M

ate

ria

l

W

eig

ht (

lbs

.)

Ste

el S

nap

 Ho

ok 

LI S

tee

l Sw

ive

l Sn

ap

 Ho

ok 

ALU

 Sn

ap

 Ho

ok 

Die

lec

tric

 Sn

ap

 Ho

ok 

 

Ste

el T

ie B

ack

 H

oo

Ste

el R

eb

ar H

oo

 

LI S

tee

l Sw

ive

l R

eb

ar H

oo

Ste

el S

wiv

el R

eb

ar H

oo

 

ALU

 Re

ba

r H

oo

Ste

el C

ap

tiv

e E

ye C

ara

bin

er 

ALU

 Ca

ptiv

e E

ye C

ara

bin

er 

ALU

 Sw

ive

l C

ara

bin

er 

No

 At

tac

hm

en

t

Ste

el C

ara

bin

er 

Trip

. Lo

ck S

tee

l C

ara

bin

er 

 

ALU

 Ca

rab

ine

ALU

 Ca

ptiv

e E

ye C

ara

bin

er  

ALU

 Sn

ap

 Ho

ok 

FS-

EX

31

Ca

b M

ou

nt B

rac

ket

 

So

ft L

oo

Inte

gra

ted

 BW

10

14

 BW

90

12

 BW

90

13

 BW

FS-FSP1420-W

1

S 20

UHMPE 

Webbing

1X.05 Polymer 5.9 X

X

FS-FSP1215-G

1

S 15 Steel Cable

3/16 Polymer 6.7

X

X

FS-FSP1215-SS

1

S 15

 

S.S. Cable

3/16 Polymer 6.7

X

X

FS-FSP1220-G

1

S 20 Steel Cable

3/16 Polymer 7.9

X

X

FS-FSP1220-SS

1

S 20

 

S.S. Cable

3/16 Polymer 7.9

X

X

FS-FSP1230-G

1

S 30 Steel Cable

3/16 Polymer 10.1

X

X

FS-FSP1230-SS

1

S 30

 

S.S. Cable

3/16 Polymer 10.1

X

X

FS-FSP1250-G

1

S 50 Steel Cable

3/16 Polymer 15.2

X

X

FS-FSP1250-SS

1

S 50

 

S.S. Cable

3/16 Polymer 15.2

X

X

FS-FSP1265-G

1

S 65 Steel Cable

3/16 Polymer 20.4

X

X

FS-EX1080-G

1

S 80 Steel Cable

3/16 Polymer 27.4

X

X

FS-EX10-100-G

1

S 100 Steel Cable

3/16 Polymer 30.4

X

X

Standards: ANSI Z359.14-2021

                    OSHA 1910.140, 1910.66, 1925.502

 

   

CONNECTOR

ATTACHMENT

Capacity:   ANSI 130-310 lbs. (59-141 kg)

 

   OSHA Up to 420 lbs. (191kg)

TABLE 1 - NORTHSTAR CLASSIC CONFIGURATION TABLE

Summary of Contents for NORTHSTAR CLASSIC SRL

Page 1: ...acturer s instructions as required by ANSI Z359 14 2021 and should be used as part of an employee training program as required by OSHA Copyright Safewaze 2022 SRL Instruction Manual 220 00084 ANSI Z35...

Page 2: ...IN REQUIRED FALL CLEARANCE 8 9 11 0 SWING FALLS 10 12 0 FALL PROTECTION AND RESCUE PLAN 11 13 0 NORMAL OPERATIONS 11 14 0 COMPATIBILITY OF COMPONENTS 11 15 0 COMPATIBILITY OF CONNECTORS 11 12 16 0 USE...

Page 3: ...ems or both that may affect or interfere with the safe function of each other DO NOT alter equipment DO NOT misuse equipment User must have a written Rescue Plan and means at hand to implement it when...

Page 4: ...e E y e C a r a b i n e r A L U S n a p H o o k F S E X 3 1 3 C a b M o u n t B r a c k e t S o f t L o o p I n t e g r a t e d B W B 1 0 1 4 B W B 9 0 1 2 B W B 9 0 1 3 B W B FS FSP1420 W 1 S 20 UHMP...

Page 5: ...anual Class 1 and 2 Class 1 Self retracting devices which shall be used only on overhead anchorages and shall be subjected to a maximum free fall of 2 feet 0 6 m or less in practical application Class...

Page 6: ...ll Clearance Figure 2 Illustrates a Fall Clearance Calculation Fall Clearance FC is the total combined values of Free Fall FF Deceleration Distance DD and a Safety Factor SF Safety Factor calculations...

Page 7: ...thorized Person A person assigned by the employer to perform duties at a location where such person will be exposed to a fall hazard 2 Rescuer Person or persons other than the rescue subject acting to...

Page 8: ...ance for each unit in prescribed condition testing with 0 offset EXAMPLE The FS FSP1215 G has Actual Arrest Distances of 16 17 17 and 34 during Ambient Wet Hot and Cold testing respectively By using t...

Page 9: ...he anchorage connector to arrest a fall before the user strikes the ground or an obstruction Figure 2 illustrates a typical Fall Clearance calculation based on the ANSI Z359 14 2021 prescribed Maximum...

Page 10: ...3 5 2 2 4 3 5 5 6 1 4 6 8 7 2 10 3 11 1 18 6 7 10 8 2 12 3 4 13 15 17 1 19 20 22 24 7 9 12 11 3 14 18 4 6 16 8 20 18 20 2 22 24 25 6 3 4 27 21 23 25 27 29 31 18 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0...

Page 11: ...ECTORS HAVE ADDITIONAL REQUIREMENTS CONTACT SAFEWAZE WITH QUESTIONS Connectors are compatible with connecting elements when they have been designed to work together in such a way that their sizes and...

Page 12: ...mmediately Equipment must then be serviced See Section 18 if applicable or disposed of See Section 19 16 0 USE 16 1 OPERATION 16 2 AFTER A FALL A full body harness must be worn when using Safewaze SRL...

Page 13: ...tracting back into the housing DO NOT USE HEAT to dry web lifeline IMPORTANT If the lifeline comes in contact with acids or other caustic chemicals remove the SRL from service and wash with water and...

Page 14: ...horizontal lifelines Adhere to the hierarchy of controls in Z359 2 Class 1 Anchor at or above dorsal D ring Working length 50 ft 15 24 m Material 3 16 in galvanized steel cable steel hardware nylon a...

Page 15: ...ok Body Rivets Corrosion Pitting Nicks CONNECTORS PASS FAIL NOTE Termination Stitch Splice or Swage Cuts Fraying Broken Stitching Excessive Wear Cable Separating Bird Caging Entire Length Retracts Smo...

Page 16: ...waze 2022 Page 16 Date Inspection Items Noted Corrective Action Initials INSPECTION LOG Safewaze 225 Wilshire Ave SW Concord NC 28025 PHONE 1 800 230 0319 FAX 1 704 262 9051 WEB safewaze com EMAIL inf...

Reviews: