background image

Copyright Safewaze 2023

Page 8

Minimum Required Fall Clearance:

The Minimum Required Fall Clearance distances indicated in Table 7 are based upon Ambient, Wet, Hot, and Cold testing results for each unit in the Latitude Pro 

Arc Flash SRL-P series.  Fall Clearances indicated in Table 7 are calculated using the greatest Actual Arrest Distance out of the four tests performed.  Table 6 

indicates the specific arrest distance in prescribed condition testing with 0’ offset.  

EXAMPLE:  

The Latitude Pro Arc Flash SRL-Ps have Actual Arrest Distances of 22”, 21”, 22”, and 23” during Ambient, Wet, Hot, and Cold testing respectively.

By using the greatest distance (Cold=23”) out of the four tests performed and inserting that value in Row B of the Chart in Figure 2, a Total Fall Clearance  

of 5’ 11” is required.  

FIGURE 1 - CLASS 1 SRL AXES DIAGRAM

Y

X

Z

Z:

 

Minimum Required 

Fall Clearance From 

Walking/Working Surface 

X:

 SRL Anchorage Height

       Above Dorsal D-ring

Y:

 Lateral Offset 

      Distance

Class 1 Axes Diagram

Model

Ambient

Wet

Hot

Cold

Latitude Pro Arc Flash Series SRL

22”

21”

22”

23”

NOTE:

  A Qualified Person must determine if MRFCs can be adjusted based upon actual jobsite atmospheric conditions or additional 

factors.  

Model

MRFC

Latitude Pro Arc Flash Series SRL-P

5’ 11” (1.8 m)

Fall Clearance:  

There must be sufficient clearance below the anchorage connector to arrest a fall before the user strikes the ground or an obstruction.  

 

Figure 2 illustrates a typical Fall Clearance calculation based on the ANSI Z359.14-2021 prescribed Maximum Allowed Free Fall of 24 in. and Maximum Allowed 

Arrest Distance of 42 in.  Fall Clearance calculations may vary dependent upon the SRL being used.  It is essential that the correct Arrest Distance is used to 

determine Minimum Required Fall Clearance.    

Personal Fall Arrest: 

Safewaze Class 1 SRLs can be used as part of a complete Personal Fall Arrest System (PFAS) for a maximum of one user.  Only one user 

may be connected to an SRL.  Avoid sharp and/or abrasive edges. If contact with an abrasive surface is unavoidable, proper edge protection must be used.  The 

structure utilized for attachment must be capable of withstanding a load of 5,000 lbs. in all directions permitted by the system. The maximum allowable free fall 

is 2 ft.    

 10.0  ACTUAL ARREST DISTANCE / MINIMUM REQUIRED FALL CLEARANCE

Safewaze SRLs are tested in accordance with ANSI Z359.14-2021 conditioning test protocols.  Table 6 reflects the actual performance of each unit in the 

Latitude Pro Arc Flash SRL-P series when subjected to Ambient, Wet, Hot, and Cold testing.  The Fall Clearance specifications in Table 8 of this manual reflect the 

 

ANSI Z359.14-2021 Maximum Arrest Distance allowance of 42”.  Actual Arrest Distances for each unit in the Latitude Pro Arc Flash SRL-P series are indicated 

below.  These Actual Arrest Distances are typically lower than the 42” maximum as specified per ANSI. In certain instances this may allow for a Qualified Person 

to adjust the Minimum Required Fall Clearances indicated in Table 8.

Actual Arrest Distance (AD):

TABLE 7 - ANSI ABOVE D-RING MINIMUM REQUIRED FALL CLEARANCE (MRFC)

TABLE 6 - ANSI ABOVE D-RING ACTUAL ARREST DISTANCES 

Summary of Contents for LATITUDE PRO ARC FLASH SRL-P

Page 1: ...0 00031 Arc Flash i 020051 ANSI Z359 14 2021 OSHA 1910 140 OSHA 1910 66 ASTM F887 470 00031 Arc Flash i 020051 ANSI Z359 14 2021 OSHA 1910 140 OSHA 1910 66 ASTM F887 470 00031 1 2 PUSH SLIDE TO OPEN A...

Page 2: ...EST DISTANCE MIN REQ FALL CLEARANCE 8 10 11 0 SWING FALLS 10 12 0 FALL PROTECTION AND RESCUE PLAN 11 13 0 NORMAL OPERATIONS 11 14 0 COMPATIBILITY OF COMPONENTS 11 15 0 COMPATIBILITY OF CONNECTORS 11 1...

Page 3: ...or both that may affect or interfere with the safe function of each other DO NOT alter equipment DO NOT misuse equipment User must have a written Rescue Plan and means at hand to implement it when us...

Page 4: ...ng 7X 05 Clear Resin 2 8 X X 020 5202 1 S 7 Kevlar Webbing 7X 05 Clear Resin 3 0 X X 020 5203 1 S 7 Kevlar Webbing 7X 05 Clear Resin 3 6 X X 020 5204 1 S 7 Kevlar Webbing 7X 05 Clear Resin 2 7 X X 020...

Page 5: ...nd tested Separate units may be used for each test All test results are recorded This test data is then used to establish the fall clearance guidelines published in this user instruction manual Class...

Page 6: ...Figure 2 Illustrates a Fall Clearance Calculation Fall Clearance FC is the total combined values of Free Fall FF Deceleration Distance DD and a Safety Factor SF Safety Factor calculations may differ...

Page 7: ...signed by the employer to perform duties at a location where such person will be exposed to a fall hazard 2 Rescuer Person or persons other than the rescue subject acting to perform an assisted rescue...

Page 8: ...ed on the ANSI Z359 14 2021 prescribed Maximum Allowed Free Fall of 24 in and Maximum Allowed Arrest Distance of 42 in Fall Clearance calculations may vary dependent upon the SRL being used It is esse...

Page 9: ...RREST DISTANCE OF 42 Lateral Offset Distance Y In Feet 0 2 4 6 8 10 15 20 25 8 7 6 2 3 m 8 3 2 5 m 9 2 7 m 10 1 3 1 m 11 4 3 5 m 12 9 4 m 17 1 5 2 m 21 6 6 6 m 26 3 8 m 10 7 6 2 3 m 8 3 2 5 m 8 9 2 7...

Page 10: ...4 ANSI A10 32 OSHA 1910 66 OSHA 1926 502 SWING FA L L An anchorage point located in a position that is not directly over the user s fall location results in a Swing Fall See Figure 3 Swing falls may r...

Page 11: ...ECTORS HAVE ADDITIONAL REQUIREMENTS CONTACT SAFEWAZE WITH QUESTIONS Connectors are compatible with connecting elements when they have been designed to work together in such a way that their sizes and...

Page 12: ...or that shows damage consistent with the effects of a fall must be removed from service immediately Equipment must then be serviced See Section 18 if applicable or disposed of See Section 19 16 0 USE...

Page 13: ...wivels should be hanging on the curved portion of bracket 4 Slide the bar behind both loops of webbing at dorsal D ring Swing the bracket closed unti it locks into place 5 Check the locking function o...

Page 14: ...ry web lifeline IMPORTANT If the lifeline comes in contact with acids or other caustic chemicals remove the SRL from service and wash with water and a mild soap solution Inspect the SRL using the Insp...

Page 15: ...O N D DO NOT ATTEMPT TO SERVICE OR REPAIR THIS UNIT CONTACT SAFEWAZE FOR SERVICE OR REPAIR INFORMATION Device must be inspected prior to each use in accordance with the manufacturer s instructions Per...

Page 16: ...887 020005 FIGURE 12 INSPECTION DIAGRAMS Load Impact Indicator Webbing Housing Labeling Labeling Swivel Top Hook Body Bracket Labeling Cover Arc Flash i 020051 ANSI Z359 14 2021 OSHA 1910 140 OSHA 191...

Page 17: ...ok Body Rivets Corrosion Pitting Nicks CONNECTORS PASS FAIL NOTE Termination Stitch Splice or Swage Cuts Fraying Broken Stitching Excessive Wear Cable Separating Bird Caging Entire Length Retracts Smo...

Page 18: ...Copyright Safewaze 2023 Page 18 Date Inspection Items Noted Corrective Action Initials INSPECTION LOG...

Page 19: ...Copyright Safewaze 2023 Page 19 This Page Intentionally Left Blank...

Page 20: ...Copyright Safewaze 2023 Page 20 Safewaze 225 Wilshire Ave SW Concord NC 28025 PHONE 1 800 230 0319 FAX 1 704 262 9051 WEB safewaze com EMAIL info safewaze com...

Reviews: