background image

Copyright Safewaze 2023

TABLE 1 - LATITUDE PRO ARC FLASH SRL-P CONFIGURATION TABLE

Part

 

Number

SR

L

 

Cla

ss

Sin

gle

 

Leg

 

(S)

 

/

 

Du

al

 

Leg

 

(D

)

W

ork

ing

 

Len

gth

 

(ft.)

Life

lin

e

 

M

ate

ria

l

Life

lin

e

 

Dim

en

sio

ns

 

(in

.)

Ho

usin

g

 

M

ate

ria

l

W

eig

ht

 

(lb

s.)

Ste

el

 

Sn

ap

 

Ho

ok

 ①

LI

 

Ste

el

 

Sw

ive

l

 

Sn

ap

 

Ho

ok

 ②

ALU

 

Sn

ap

 

Ho

ok

 ③

Die

lec

tric

 

Sn

ap

 

Ho

ok

 ④

 

Ste

el

 

Tie

 

Ba

ck

 

Ho

ok

 ⑤

Ste

el

 

Re

ba

r

 

Ho

ok

 ⑥

 

LI

 

Ste

el

 

Sw

ive

l

 

Re

ba

r

 

Ho

ok

 ⑦

Ste

el

 

Sw

ive

l

 

Re

ba

r

 

Ho

ok

 ⑧

 

ALU

 

Re

bar

 

Ho

ok

 ⑨

Ste

el

 

Ca

ptiv

e

 

Eye

 

Ca

rab

ine

r

 ⑩

ALU

 

Ca

ptiv

e

 

Eye

 

Ca

rab

ine

r

 ⑪

ALU

 

Sw

ive

l

 

Ca

rab

ine

r

 ⑫

No

 

Att

ach

m

en

t

Ste

el

 

Ca

rab

ine

r

 ⑬

Trip

.

 

Loc

k

 

Ste

el

 

Ca

rab

ine

r

 ⑭

 

ALU

 

Ca

rab

ine

r

 ⑮

ALU

 

Ca

ptiv

e

 

Eye

 

Ca

rab

ine

r

  ⑪

ALU

 

Sn

ap

 

Ho

ok

 ③

FS

EX

31

3

 ⑯

Ca

b

 

M

ou

nt

 

Bra

cke

t

 ⑰

So

ft

 

Lo

op

 ⑱

Inte

gra

ted

 

BW

B

 ⑲

10

14

 

BW

B

 ⑳

90

12

 

BW

B

 

90

13

 

BW

B

 

020

5200

1

S

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 3.0 X

X

020

5201

1

S

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 2.8

X

X

020

5202

1

S

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 3.0

X

X

020

5203

1

S

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 3.6

X

X

020

5204

1

S

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 2.7 X

X

020

5205

1

S

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 3.7

X

X

020

5206

1

S

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 2.5

X

X

020

5207

1

S

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 3.3

X

X

020

5208

1

S

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 2.8

X

X

021

5285

1

S

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 3.1

X

X

020

5213

1

D

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 5.1 X

X

020

5214

1

D

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 7.1

X

X

020

5215

1

D

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 4.7

X

X

020

5216

1

D

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 6.3

X

X

020

5221

1

D

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 5.5

X

X

020

5217

1

D

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 5.0 X

X

020

5218

1

D

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 7.1

X

X

020

5219

1

D

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 4.7

X

X

020

5220

1

D

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 6.3

X

X

022

5308

1

S

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 2.5

X

X

022

5309

1

S

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 2.5

X

X

022

5310

1

S

7

Kevlar®

Webbing

 

.7X.05 Clear

 

Resin 2.5

X

X

Standards: ANSI Z359.14-2021

                    OSHA 1910.140, 1910.66

 

    ASTM F887

CONNECTOR

ATTACHMENT

Copyright Safewaze 2022

Capacity:   ANSI 130-310 lbs. (59-141 kg)

 

   OSHA Up to 420 lbs. (191kg)

Summary of Contents for LATITUDE PRO ARC FLASH SRL-P

Page 1: ...0 00031 Arc Flash i 020051 ANSI Z359 14 2021 OSHA 1910 140 OSHA 1910 66 ASTM F887 470 00031 Arc Flash i 020051 ANSI Z359 14 2021 OSHA 1910 140 OSHA 1910 66 ASTM F887 470 00031 1 2 PUSH SLIDE TO OPEN A...

Page 2: ...EST DISTANCE MIN REQ FALL CLEARANCE 8 10 11 0 SWING FALLS 10 12 0 FALL PROTECTION AND RESCUE PLAN 11 13 0 NORMAL OPERATIONS 11 14 0 COMPATIBILITY OF COMPONENTS 11 15 0 COMPATIBILITY OF CONNECTORS 11 1...

Page 3: ...or both that may affect or interfere with the safe function of each other DO NOT alter equipment DO NOT misuse equipment User must have a written Rescue Plan and means at hand to implement it when us...

Page 4: ...ng 7X 05 Clear Resin 2 8 X X 020 5202 1 S 7 Kevlar Webbing 7X 05 Clear Resin 3 0 X X 020 5203 1 S 7 Kevlar Webbing 7X 05 Clear Resin 3 6 X X 020 5204 1 S 7 Kevlar Webbing 7X 05 Clear Resin 2 7 X X 020...

Page 5: ...nd tested Separate units may be used for each test All test results are recorded This test data is then used to establish the fall clearance guidelines published in this user instruction manual Class...

Page 6: ...Figure 2 Illustrates a Fall Clearance Calculation Fall Clearance FC is the total combined values of Free Fall FF Deceleration Distance DD and a Safety Factor SF Safety Factor calculations may differ...

Page 7: ...signed by the employer to perform duties at a location where such person will be exposed to a fall hazard 2 Rescuer Person or persons other than the rescue subject acting to perform an assisted rescue...

Page 8: ...ed on the ANSI Z359 14 2021 prescribed Maximum Allowed Free Fall of 24 in and Maximum Allowed Arrest Distance of 42 in Fall Clearance calculations may vary dependent upon the SRL being used It is esse...

Page 9: ...RREST DISTANCE OF 42 Lateral Offset Distance Y In Feet 0 2 4 6 8 10 15 20 25 8 7 6 2 3 m 8 3 2 5 m 9 2 7 m 10 1 3 1 m 11 4 3 5 m 12 9 4 m 17 1 5 2 m 21 6 6 6 m 26 3 8 m 10 7 6 2 3 m 8 3 2 5 m 8 9 2 7...

Page 10: ...4 ANSI A10 32 OSHA 1910 66 OSHA 1926 502 SWING FA L L An anchorage point located in a position that is not directly over the user s fall location results in a Swing Fall See Figure 3 Swing falls may r...

Page 11: ...ECTORS HAVE ADDITIONAL REQUIREMENTS CONTACT SAFEWAZE WITH QUESTIONS Connectors are compatible with connecting elements when they have been designed to work together in such a way that their sizes and...

Page 12: ...or that shows damage consistent with the effects of a fall must be removed from service immediately Equipment must then be serviced See Section 18 if applicable or disposed of See Section 19 16 0 USE...

Page 13: ...wivels should be hanging on the curved portion of bracket 4 Slide the bar behind both loops of webbing at dorsal D ring Swing the bracket closed unti it locks into place 5 Check the locking function o...

Page 14: ...ry web lifeline IMPORTANT If the lifeline comes in contact with acids or other caustic chemicals remove the SRL from service and wash with water and a mild soap solution Inspect the SRL using the Insp...

Page 15: ...O N D DO NOT ATTEMPT TO SERVICE OR REPAIR THIS UNIT CONTACT SAFEWAZE FOR SERVICE OR REPAIR INFORMATION Device must be inspected prior to each use in accordance with the manufacturer s instructions Per...

Page 16: ...887 020005 FIGURE 12 INSPECTION DIAGRAMS Load Impact Indicator Webbing Housing Labeling Labeling Swivel Top Hook Body Bracket Labeling Cover Arc Flash i 020051 ANSI Z359 14 2021 OSHA 1910 140 OSHA 191...

Page 17: ...ok Body Rivets Corrosion Pitting Nicks CONNECTORS PASS FAIL NOTE Termination Stitch Splice or Swage Cuts Fraying Broken Stitching Excessive Wear Cable Separating Bird Caging Entire Length Retracts Smo...

Page 18: ...Copyright Safewaze 2023 Page 18 Date Inspection Items Noted Corrective Action Initials INSPECTION LOG...

Page 19: ...Copyright Safewaze 2023 Page 19 This Page Intentionally Left Blank...

Page 20: ...Copyright Safewaze 2023 Page 20 Safewaze 225 Wilshire Ave SW Concord NC 28025 PHONE 1 800 230 0319 FAX 1 704 262 9051 WEB safewaze com EMAIL info safewaze com...