Tubing Connectors

Connect :

Cut the tubing squarely with a sharp knife. Be careful not to crush the tubing. To avoid 

leaks, make sure the tubing end is smooth and free of burrs and abrasions. Lubricate 

the end of the tube with water or a light coat of silicone and push the tube end firmly 

into the fitting. You should feel it push past the O-ring. Avoid bending the tubing sharply 

away from the fitting.

Disconnect :

Hold the collar against the fitting body and pull the tube from the fitting. In the unlikely

event that the connection leaks, remove and recut the tubing. Check the inside of the 

fitting for debris or O-ring damage. Reconnect. Push-to-connect tubing connectors 

grip the outside diameter of the tube. To help assure a reliable connection,  it is important 

to use high quality tubing with a consistent outside diameter.

Quick-Connect Fitting

Insertion & Removal of Plastic or Copper Tubing  

1. Simply push in tube to attach.    2. Tube is secured in position.

3. Push in collet from both sides to release tubing. 

Cut tube squarely 
with a sharp knife.

Step 1 

 Select Component Installation Locations

• 

Dispenser Faucet 

   – The faucet is designed to be mounted on the rear lip of the sink. It may be installed in an existing sprayer 

     attachment hole or in a hole drilled at the time of installation. It may also be mounted to an adjacent counter 

     top. It should be positioned so that water is dispensed over the sink. A 7/8” diameter hole is required.

• Important considerations

   – Access to the bottom (undersink) of the faucet is required for attachment of product water line.

   – There should be no undersink obstructions which would prevent smooth tubing runs to the drain connection,

     or RO module assembly.

• Filter System Assembly 

   – The filter system assembly is designed to be mounted on any rigid vertical surface such as a cabinet sidewall, 

     sheetrock in exposed stud. It should be positioned such that there is access to an inlet water source and drain.

     The installation should also allow convenient access for servicing.

• Inlet Water Supply Connection

   – Once a location is chosen for installation of the filter system assembly, select a nearby cold water line to 

     provide the water source for the system.

• Drain Connection

   – The most convenient entry to the drain is directly above the P-trap of the kitchen sink. However, the drain 

     water from the system can be connected to adjacent sinks or a floor drain. Extra care should be taken when 

     entering drains near dishwashers or food waste disposals as back flow may occur through the air gap and 

     cause flooding.

Note : Follow all local plumbing codes when connecting to drain.

Note : Follow all local plumbing codes when connecting to service water.

I

 Installation & Maintenance Guide 6

Summary of Contents for 4 Stage Ro

Page 1: ...he instructions carefully before using or installing the product and ensure that the manual is kept in a safe place for future reference The system must be properly installed and located in accordance...

Page 2: ...I Installation Maintenance Guide...

Page 3: ...eriodically to verify that the system is performing properly SAFE PRACTICES Throughout this manual there are paragraphs set off by special headings Note Note is used to emphasize installation operatio...

Page 4: ...Manufacturer s Specification only with inlet conditions of 50 psi 25 77 going to atmosphere The actual volume of product water and rejection percentage will bary with differences from the test condit...

Page 5: ...llons 5 678 Liters 1 500 Gallons 5 678 Liters 2 500 Gallons 9 463 Liters 2 500 Gallons 9 463 Liters Dimensions Replacement Cartridge 100mm Total 548mm 100mm 200mm 200mm Cupboard Wall Note Rated life a...

Page 6: ...both Special sampling procedures are needed for a lab to determine what type and how much of each type of arsenic is in the water Check with the labs in your area to see if they can provide this type...

Page 7: ...INSTALLATION DIAGRAM 1 4 Angle Stop Adaptor Valve ASVPP1 1 4 Orange Tube NCPV 893 CP KR01 1 4 Blue Tube J G Tank Shut Off Valve 1 4 White Tube Pressure Tank TP 12P 1 4 Drain Saddle Valve 1 4 Black Tub...

Page 8: ...drilled at the time of installation It may also be mounted to an adjacent counter top It should be positioned so that water is dispensed over the sink A 7 8 diameter hole is required Important consid...

Page 9: ...epped 7 8 drill bit If no stepped bit is available start by drilling a 1 4 hole Using this hole as a starting point progressively drill larger holes Increase drill size by 1 8 until you reach a 7 8 ho...

Page 10: ...the standard faucets drill a 1 4 hole through one side of the pipe The drill should be kept straight and centered to avoid damaging the saddle valve Do not drill through both sides of the pipe CAUTION...

Page 11: ...n at optimal efficiency 9 Close faucet and allow tank to fill 10 System is ready to use 4 Attach 1 4 black tube by slipping the tube through the black compression nut and hand tighten the nut on to th...

Page 12: ...the actual performance of the RO membrane filter to the standard temperature of 77 F 25 C This allows the performance of the unit to be accurately gauged against published standards Temperature does...

Page 13: ...a Use optional large tank for more storage capacity b Insufficient feed water flow b 1 Clogged shut off valve or feed tubing clean out or replace 2 Clogged prefilter replace 3 Clogged manifold clean o...

Page 14: ...a Carbon fines a Flush polishing filter 11 Low faucet pressure a Inadequate pre charge pressure in storage tank a Check tank pre charge pressure and add air if required b Polishing filter plugged b Re...

Page 15: ...ion before or after the system 4 Damage to the product caused by accident fire floods or acts of God 5 Incidental or consequential damage caused by possible defects with this application it s installa...

Page 16: ...ROFILTRATION SYSTEM...

Reviews: