Problem

Possible Cause

Remedy

8. Bad smell from 

    product water. 

a. Polishing filter exhausted.

a. Replace polishing filter.

b. Prefilter element.

b. Replace filter element.

c. Unit needs disinfection.

c. Sanitize unit.

9. Fast flow to drain.

a. Defective flow control assembly.

a. Replace flow control assembly.

 

10. Black specks in 

       product water. 

a. Carbon fines.

a. Flush polishing filter.

 

11. Low faucet pressure. 

a. Inadequate pre-charge pressure in 

    storage tank. 

a. Check tank pre-charge pressure and add 

    air if required. 

b. Polishing filter plugged.

b. Replace polishing filter.

 

12. Flow control plugging.  a. Excessive turbidity.

a. Install another 5 micron filter in series with 

    existing one or substitute carbon block 

    filter for granular activated carbon filter.  

b. Iron fouled.

b. Pretreat for iron removal.

c. Iron-bacteria fouled.

c. Sanitize plumbing.

I

 Installation & Maintenance Guide 12 

Summary of Contents for 4 Stage Ro

Page 1: ...he instructions carefully before using or installing the product and ensure that the manual is kept in a safe place for future reference The system must be properly installed and located in accordance...

Page 2: ...I Installation Maintenance Guide...

Page 3: ...eriodically to verify that the system is performing properly SAFE PRACTICES Throughout this manual there are paragraphs set off by special headings Note Note is used to emphasize installation operatio...

Page 4: ...Manufacturer s Specification only with inlet conditions of 50 psi 25 77 going to atmosphere The actual volume of product water and rejection percentage will bary with differences from the test condit...

Page 5: ...llons 5 678 Liters 1 500 Gallons 5 678 Liters 2 500 Gallons 9 463 Liters 2 500 Gallons 9 463 Liters Dimensions Replacement Cartridge 100mm Total 548mm 100mm 200mm 200mm Cupboard Wall Note Rated life a...

Page 6: ...both Special sampling procedures are needed for a lab to determine what type and how much of each type of arsenic is in the water Check with the labs in your area to see if they can provide this type...

Page 7: ...INSTALLATION DIAGRAM 1 4 Angle Stop Adaptor Valve ASVPP1 1 4 Orange Tube NCPV 893 CP KR01 1 4 Blue Tube J G Tank Shut Off Valve 1 4 White Tube Pressure Tank TP 12P 1 4 Drain Saddle Valve 1 4 Black Tub...

Page 8: ...drilled at the time of installation It may also be mounted to an adjacent counter top It should be positioned so that water is dispensed over the sink A 7 8 diameter hole is required Important consid...

Page 9: ...epped 7 8 drill bit If no stepped bit is available start by drilling a 1 4 hole Using this hole as a starting point progressively drill larger holes Increase drill size by 1 8 until you reach a 7 8 ho...

Page 10: ...the standard faucets drill a 1 4 hole through one side of the pipe The drill should be kept straight and centered to avoid damaging the saddle valve Do not drill through both sides of the pipe CAUTION...

Page 11: ...n at optimal efficiency 9 Close faucet and allow tank to fill 10 System is ready to use 4 Attach 1 4 black tube by slipping the tube through the black compression nut and hand tighten the nut on to th...

Page 12: ...the actual performance of the RO membrane filter to the standard temperature of 77 F 25 C This allows the performance of the unit to be accurately gauged against published standards Temperature does...

Page 13: ...a Use optional large tank for more storage capacity b Insufficient feed water flow b 1 Clogged shut off valve or feed tubing clean out or replace 2 Clogged prefilter replace 3 Clogged manifold clean o...

Page 14: ...a Carbon fines a Flush polishing filter 11 Low faucet pressure a Inadequate pre charge pressure in storage tank a Check tank pre charge pressure and add air if required b Polishing filter plugged b Re...

Page 15: ...ion before or after the system 4 Damage to the product caused by accident fire floods or acts of God 5 Incidental or consequential damage caused by possible defects with this application it s installa...

Page 16: ...ROFILTRATION SYSTEM...

Reviews: