Safeway water 4 Stage Ro Installation & Maintenance Manual Download Page 4

2. Specifications   

Sediment
Filter

Purpose

Sediment

Reduction

Chlorine Taste

and Odor

Micron

Rating

Capacity

2500 gallons

(9460 liters)

Flow Rate

0.5 gal/min

(1.9 liters/min)

Rated Life

Stage

6 Months

Working

Temperature

Range

4-38°C

(40-100°F)

Working

Pressure

Range

30-125 psi

Carbon Block
Filter

5

5

1

2&4

Replacement Filter

RO
Membrane
50 GPD

Purpose

TDS

Reduction

Recovery

(product  Water 

 / Inlet Water)

TDS

Reduction*

96%

Rating**

50 gallons/day

(189 liters/day)

(No Storage

Tank Attached)

Rated Life

Stage

24 Months

Working

Temperature

Range

4-38°C

(40-100°F)

Working

Pressure

Range

(1)

40-125 psi

30%

3

* The performance and life of a reverse osmosis membrane or filter element is highly dependent upon pressure, temperature and dissolved  solids (TDS)
** Manufacturer's Specification only with inlet  conditions of 50 psi, 25

 (77

), going to atmosphere. The actual volume of product water and rejection percentage will bary 

    with differences from the test conditions that membrane ratings are based upon
(1) Pressure Regulator is recommended for feed water pressures exceeding 80psi

Stage 1

Stage 2

Stage 3

Stage 4

Storage Tank

Faucet

Sediment Filter

Activated Carbon Filter

Activated  Carbon Filter

Reverse Osmosis 

Membrane

TP-12P

NCPV 893

CP-KR01

Daily Production Rate*

76.8(20.3)

Sediment Filter 

 Activated Carbon Prefilter

 Reverse Osmosis Membrane 

 Storage Tank

 Activated Carbon Postfilter

 Dispensing Faucet 

5 Micron

Carbon Block 5 Micron

Thin Film Composite

Metal – Capacity 3.2 Gallon (12 Liters)   

L/day (G/day)

Typical System Flow Sequence

Sediment Filter (Stage 1)

Activated Carbon Prefilter & Postfilter (Stage 2&4)

Reverse  Osmosis Membrane (Stage 3)

Storage Capacity  

I

 Installation & Maintenance Guide 2 

Summary of Contents for 4 Stage Ro

Page 1: ...he instructions carefully before using or installing the product and ensure that the manual is kept in a safe place for future reference The system must be properly installed and located in accordance...

Page 2: ...I Installation Maintenance Guide...

Page 3: ...eriodically to verify that the system is performing properly SAFE PRACTICES Throughout this manual there are paragraphs set off by special headings Note Note is used to emphasize installation operatio...

Page 4: ...Manufacturer s Specification only with inlet conditions of 50 psi 25 77 going to atmosphere The actual volume of product water and rejection percentage will bary with differences from the test condit...

Page 5: ...llons 5 678 Liters 1 500 Gallons 5 678 Liters 2 500 Gallons 9 463 Liters 2 500 Gallons 9 463 Liters Dimensions Replacement Cartridge 100mm Total 548mm 100mm 200mm 200mm Cupboard Wall Note Rated life a...

Page 6: ...both Special sampling procedures are needed for a lab to determine what type and how much of each type of arsenic is in the water Check with the labs in your area to see if they can provide this type...

Page 7: ...INSTALLATION DIAGRAM 1 4 Angle Stop Adaptor Valve ASVPP1 1 4 Orange Tube NCPV 893 CP KR01 1 4 Blue Tube J G Tank Shut Off Valve 1 4 White Tube Pressure Tank TP 12P 1 4 Drain Saddle Valve 1 4 Black Tub...

Page 8: ...drilled at the time of installation It may also be mounted to an adjacent counter top It should be positioned so that water is dispensed over the sink A 7 8 diameter hole is required Important consid...

Page 9: ...epped 7 8 drill bit If no stepped bit is available start by drilling a 1 4 hole Using this hole as a starting point progressively drill larger holes Increase drill size by 1 8 until you reach a 7 8 ho...

Page 10: ...the standard faucets drill a 1 4 hole through one side of the pipe The drill should be kept straight and centered to avoid damaging the saddle valve Do not drill through both sides of the pipe CAUTION...

Page 11: ...n at optimal efficiency 9 Close faucet and allow tank to fill 10 System is ready to use 4 Attach 1 4 black tube by slipping the tube through the black compression nut and hand tighten the nut on to th...

Page 12: ...the actual performance of the RO membrane filter to the standard temperature of 77 F 25 C This allows the performance of the unit to be accurately gauged against published standards Temperature does...

Page 13: ...a Use optional large tank for more storage capacity b Insufficient feed water flow b 1 Clogged shut off valve or feed tubing clean out or replace 2 Clogged prefilter replace 3 Clogged manifold clean o...

Page 14: ...a Carbon fines a Flush polishing filter 11 Low faucet pressure a Inadequate pre charge pressure in storage tank a Check tank pre charge pressure and add air if required b Polishing filter plugged b Re...

Page 15: ...ion before or after the system 4 Damage to the product caused by accident fire floods or acts of God 5 Incidental or consequential damage caused by possible defects with this application it s installa...

Page 16: ...ROFILTRATION SYSTEM...

Reviews: