24
INSPECTION RECORD
Product Code
Date of Manufacture
Serial or Batch No.
Date of Install
Inspector
Date of Inspection
PROCEDURE
INSPECTION
USER
COMPETENT
PERSON
8.3.1
Cable - inspect the cable for damage, deformation,
broken wires or strands, or debris that may affect the
strength of the cable or impede the Shuttle.
Comments:
8.3.2
Top Bracket - inspect all fasteners are present and
tight. Inspect the stainless steel for chips, cracks,
discolouration, damage to the protective coating,
bending or warping. Inspect any welds for corrosion,
discolouration or damage. Inspect any steel tubes for
damage of the galvanising, deformation or corrosion.
Comments:
8.3.3
Bottom Bracket - inspect all fasteners are present
and tight. Inspect the stainless steel for chips, cracks,
discolouration, damage to the protective coating,
bending or warping. Inspect any welds for corrosion,
discolouration or damage. Inspect any steel tubes for
damage of the galvanising, deformation or corrosion.
Comments:
8.3.4
Tension - inspect all fixings are present and tight.
Inspect fixings are free of damage, debris, cracks, and
corrosion.
Comments:
8.3.5
Cable Guides - inspect all fixings are present and tight.
Inspect the galvanised coat is free of chips, cracks,
corrosion or damage. Inspect the rubber end accepts
and holds the cable, is free of cracks and missing
piece.
Comments:
8.3.6
Shuttle - inspect the housing is free of cracks, damage
or deformation. Inspect the energy absorber is not
deployed. Inspect the connector is free of cracks,
damage or deformation and functions correctly.
Ensure all screws are present and not loose. Inspect
the latch opens freely and closes automatically.
Comments:
8.3.7
Proof Load - for competent person inspections only,
concrete fixings that do not extend through the
concrete shall be proof loaded to 50% of the design
load and held for 30 seconds.
N/A
Comments:
8.3.8
Label - inspect the system label is present and legible
as per Figure 29.
Comments: