Return to Table of Contents
Ref: SafetyLink Pty Ltd Permanent Ladder System
Page 12 of 36
Doc ID: MKT-471 Version: 19.0
LADDER INSTALLATION STEPS
1.
Determine the best location for ladder access by completing a risk assessment and SWMS.
2.
Select the most appropriate pitch for safe ladder access, 75 or 90 degrees.
3.
Always use an angle measuring device to set ladders to correct pitch.
4.
Calculate the required ladder length between the
top rung and the base of the ladder.
Length (H)=
Height (Y
)x1.064
5.
Assemble ladder sections and
cut only the base
of the ladder section to achieve desired ladder
length.
75 Degree
Ladder
90 Degree
Ladder