OPERATION
CONNECTIONS
1. Connect the brazing gun, power and trigger cables to the unit.
2. Connect the ground cable .
3. Connect the grinder. If unit was supplied with battery power grinder, make sure that the bat-
teries are charged. Se manufactures instruction for the grinder on charging the grinder batteries.
GRINDING
Before brazing, the braze area must be cleaned of rust, corrosion, paint, pits, or other
contamination at the points where the brazing is going to be done and on an area close to the
brazing for placement of the grounding cable.
Cleaning is accomplished with a grinder to ensure clean, bare metal.
Always use eye protection when grinding and brazing.
Note
, use only Safetrack’s grinding wheel specially made for brazing, other type of wheels will
leave a surface not suitable for brazings.
Keep the grinding wheel clean and free from oil etc.
1. Grind the brazing and ground area until you have
an even and clean surface.
2. Attach the ground magnet on the same work piece
where the pinbrazing should be done. Try to attach
the magnet within 0,5m from brazing area.
3. Move the grinder all time when grinding to get an
even surface.
8
CAUTION
Brazing
Ground
Brazing