19
Trouble-Shooting 2
Display
Problem Description
Operation Instructions
Er30
Unit disabled
Use different type of override
Er31
Master disabled
Use override unit or code
Er32
Wrong master
Use iButton or code
Er35
Wrong master
Use card or code
Er36
Master disabled
Use different type of override
Er37
Memory problem
Replace main PCB
Er38
Master defin. Err.
Factory Error
Er39
Memory problem
Try process again.
Er40
Wrong key
Open with code or card
Er41
Button disabled
Use code or card
Er42
No Code Entered
Enter code and lock
Er43
Wrong key
Open with code or iButton
Er44
Wrong key
Open with card or iButton
Er45
Illegal Operat.
Use code or iButton
Er46
Illegal Card
Use different card
Er47
Illegal Button
Use different iButton
Er48
Keypad disabled
Use card or iButton
Er50
Keypad disabled
Use card or iButton
Er64
No master defined
Factory Error
Er66
Master defin. Err.
Factory Error
Er67
Master defin. Err.
Factory Error
Er68
Master defin. Err.
Factory Error
Er70
Software error.
Er71
Illegal Time
Check designated operation time
Er73
Card Unauthorized
Try to close with a different card
Er74
Can't Add Card
Card already registered
Er75
Can't Add Card
Illegal user card
Er76
Can't Delete Card
Not a registered card user
Er77
Factory Error
Factory Error
Er78
Can't Add Card
Memory full
Er79
Add/Del Time Ended
Start process again
Er80
Bad Card
Can't register this card
Er81
Factory Error
Factory Error
Er82
Factory Error
Factory Error
Er83
Can't Close with This Card
Illegal user card
Er84
Memory problem
Replace main PCB
Er85
Memory problem
Replace main PCB
Manufacturer Problems
Override Problems
Operational Problems in Dual Safes