![background image](http://html2.mh-extra.com/html/safeline/sl3000/sl3000_manual_3314734020.webp)
20
SL3000 v.5.01 EN
OTHER CODES
CODE DATA
COMMENTS
Buzzer
*71*
- #
The buzzer will sound at incoming call or at
intercom use.
1 = On (Default)
0 = Off
Ring-tone timeout
*72*
- - #
Number of ring signals before dialling the next number.
Hot Line
*75*
- #
Phone connects directly to a fixed receipient without
dialling a phone number
0 = Standard phone line (Default)
1 = Hotline
Indicator mode
*78*
- #
0 = Standard
1 = Strictly EN81-28
Maximum communication
time
*79*
- #
1 - 20 minutes. Default = 8 min
Reset active alarm
*80*
#
0 = OFF,
1 = ON (Default)
Auto answer
*81*
- - #
No of signals before SafeLine answers incoming call.
Can be set from 00-16. 00 = Never answering.
(Default = 02)
Unit number
*82*
- #
Program Unit number [0-9], when units share phone line.
Detect dial tone
*83*
- #
0 = Off
1 = On (Default)
Set to off if SafeLine has problem to detect the dial tone.
Receipt to alarm receiver
*84*
- #
Select which message(s) to send to the alarm receiver
at an alarm call.
0 = None (Default)
1 = Start of alarm
2 = Start+end of alarm
Local button
*85*
- #
Used if car stations has built in alarm button.
0 = OFF (Default)
1 = ON
Break on
new alarm
*86*
- #
Disconnects a call longer than 60 seconds at new
activation of the alarm button and calls the next
emergency call number.
0 = OFF
1 = ON (Default)
Alarm button
delay time
*87*
- - #
Delay time from pressing the alarm button until
activating the alarm.
00-25 seconds. Default = 10.