background image

12

SL2 v. 2.01 EN

Configuration

DISTRESS MESSAGE

CODE DATA

COMMENTS

Record distress message 

played in the lift car.

*51*

”Speak” # This message will be played in the lift cabin when the 

emergency lift telephone starts calling the alarm centre. 

Make sure that there is no noice in the background when 

recording the message. Recording will be done with the 

internal microphone of the SL2. 

Example of message: Please do not panic, the emergency 

telephone is now calling the emergency call centre. 

Record alarm message 

from Lift Car to alarm 

central

*52*

”Speak” # This message will be played to the alarm receiver and in 

the car when the call is answered. Make sure that there is 

no noice in the background when recording the message. 

Recording will be done with the internal microphone of 

the SL2.

Example of message: This is an alarm from the lift on 

5th avenue. To hear the this message again, press “1”. To 

terminate the call, press “#” before hanging up.

Options for the recorded 

distress message

*61*

  - #

0 = Disable recorded message. 

1 = Enables recorded message.

*61*

#

Play the the recorded message.

Options for the recorded 

message from lift car

*62*

  - #

0 = Disable recorded message. 

1 = Enables recorded message.

*62*

#

Play the the recorded message.

OTHER CODES 

CODE DATA

COMMENTS

End of alarm message 

with voice

*70*

- #

When the end of alarm signal is given (reset) the unit will 

automatically call the 1st emergency number that enables 

the technician to confirm the operator that the alarm is 

ended (not possible when using the messages end of 

alarm, see code *84*).

0 = without end of alarm call back

1 = call back end of alarm

Emergency signal in 

speaker

*71*

- #

The speaker siren will sound at emergency call. 

1 = On

0 = Off (Default)

Ring tone timeout

*72*

- - #

Number of ring signals before dialling the next number. 

(8 by default)

Additional input 

function

*73*

- #

Selects input function:

0 = None (Default)

1 = Filter, blocks the alarm input when active.

2 = LMS (Lift Monitoring System), sends a lift monitoring 

alarm at input activation.

3 = Clear/Maintenance

Additional input type

*74*

- #

0 = Normally-open contact, NO (Default)

1 = Normally-closed contact, NC

Hot Line

*75*

- #

Phone connects directly to a fixed receipient without 

dialling a phone number

0 = Standard phone line (Default)

1 = Hotline

Compatibillity mode

*77*

- #

0 = Automatic voice switching. The call is validated when there is a 

voice response. The call is terminated by pressing ”#”.

1=Kone ECII (lift telephone)

When there is a voice response, some ascending tones will be 

heard. The call is validated by pressing ”4”. The call is terminated 

by pressing ”0”. The call is terminated without reciept notification 

by pressing ”2”(the unit will call the next number).

2 = Manual voice switching. When there is a voice response, some 

ascending tones will be heard. The call is validated by pressing 

”4”. Unit is still in automatic mode. To enter manual mode and talk 

press ”*”. To listen press ”7”. Go back to automatic mode press 

”4”. The call is terminated by pressing ”#”. It is possible to enter 

manual voice switching mode although the unit is programmed as 

automatic by pressing ”*”. No ascending tones will be heard.

3 = Swiss M (Alarm operator mode)

Only to be used in voice mode. Disconnect by “0”.Dials the next 

number if call timeout, blocking tone, new dailing tone, and 

operator silence.

Summary of Contents for SL2

Page 1: ...w safeline group com 02 2019 2019SafeLine andall the SafeLine productsand accessoriesarecopyrightedby law Reliability broughttoyou from Tyres Sweden SL2 Manual Emergency telephone for lifts SL2v 2 01E...

Page 2: ...en collector Loudspeaker 3W 8 Size W x D x H 171 x 89 x 41mm Weight 0 47kg Technicaldata Content Introduction Technicaldata 2 Generalinformation 3 Overview Overview 4 Measurements componentlist 5 Inst...

Page 3: ...hemanufacturer accepts noliability arisingfromprintingerrors mistakesorchanges Declarationofconformity Download The declarationofconformity atourwebsite www safeline group com SafetyPrecautions Only t...

Page 4: ...olume control for extra station 2 Turn clockwise to increase volume 4 RS232 PC connection For firmware update and programming 5 Emergency call button After an active alarm the button can be used as a...

Page 5: ...9 ALARM 59 39 31 69 2 x 5 2 x 9 5 RJ12 SL2v 2 01 EN Overview SafeLine SL2 Main unit Article number SL2 Measurements andcomponent list Microphone Button SafeLine SL2 alarm button and microphone Articl...

Page 6: ...2 alarm button microphone and speaker Article number LT stat02 Button Speaker Speaker SL2 COP station with speaker Article number LT stat04 Surface has to be clean and de greased if you want to make u...

Page 7: ...am Extra stations optional Telephone line in HL1 optional With parallel wiring it is important every unit is programmed with a unit number This cannot be done with remote programming Telephone line in...

Page 8: ...it Programming with SafeLine Pro The unit can be programmed at the office prior to the installation or on site after installation with a programming cable Our product PCable Use SafeLine Pro v4 02 or...

Page 9: ...rst SafeLine answers Press unit no 1 9 repeatedly until 3 beeps 3 beeps SafeLine answers Start programming 2 short beeps waiting for password Call disconnected or end of programming SLwill restart wit...

Page 10: ...est alarm 5 LMS phone number 6 Test alarm 7 End configuration If at any time you need to start over use the factory reset command 99 1 Example 1 Storing of two different telephone numbers both to be a...

Page 11: ...alarm operator is using any of the mentioned protocols Call type 2nd number 22 Call type 3rd number 23 Call type 4th number 24 Call type LMS number 30 LMS Lift Monitoring System call type 0 P100 3 CPC...

Page 12: ...m see code 84 0 without end of alarm call back 1 call back end of alarm Emergency signal in speaker 71 The speaker siren will sound at emergency call 1 On 0 Off Default Ring tone timeout 72 Number of...

Page 13: ...larm 00 25 seconds Default 05 Alarm button type 89 0 Normally open contact NO Default 1 Normally closed contact NC Change password 91 Change password default 0000 Simulate an alarm event 94 Triggers a...

Page 14: ...0 YellowLED GreenLED Lightoff Noalarmactivated TelephonelinenotOK Flashingslowly Flashingonceevery5seconds Telephoneline notOK Flashingonceevery5seconds UnitisOK Flashingquickly Flashingtwiceeveryseco...

Page 15: ...Telephone line connected Green LED flashes every 5 sec if valid tele phone line connected and set to standard Press on keypad Phone line dial tone Dial out on keypad Yellow LED flashes every 5 sec Ye...

Page 16: ...ne number Answer Calling 4th phone number Calling 3rd phone number Answer Answer Answer Alarm operator made connection Maximum 12 calls with 4 stored telephone num bers each number could be called 3 t...

Page 17: ...ce is not available check the telephone line Unit breaks off in the start sequence of the alarm call Power supply is too weak Battery is weak or not charged Operator cannot hear the entrapped people i...

Page 18: ...by changing it s position or finding another pair that is free of distortion or use shielded pair when availably When none of these solutions apply install a separate cable for the telephone line Tel...

Page 19: ...ucts referred to above complies with the following EC Directives Directives Electro Magnetic Compatibility 2014 30 EU RoHS 2 2011 65 EU Standards applied EN 81 20 2014 Lift Safety Technical requiremen...

Page 20: ...49 0 6203 840 60 03 sld safeline eu SafeLine Norway Solbr veien 49 1383 Asker Norway Tel 47 94 14 14 49 post safeline no SafeLine Denmark Erhvervsvej 19 2600 Glostrup Denmark Tel 45 44 91 32 72 info d...

Reviews: